Search icon

ALL FRAMING SERVICES INC. - Florida Company Profile

Company Details

Entity Name: ALL FRAMING SERVICES INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ALL FRAMING SERVICES INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Nov 2020 (4 years ago)
Document Number: P20000091110
FEI/EIN Number 36-4982300

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 608 W Dixie St, Plant City, FL, 33563, US
Mail Address: 608 W Dixie St, Plant City, FL, 33563, US
ZIP code: 33563
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RUIZ JOSE J President 608 W Dixie St, Plant City, FL, 33563
RUIZ DINA Vice President 608 W Dixie St, Plant City, FL, 33563
RUIZ JOSE J Agent 608 W Dixie St, Plant City, FL, 33563

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2023-04-30 608 W Dixie St, Plant City, FL 33563 -
CHANGE OF MAILING ADDRESS 2023-04-30 608 W Dixie St, Plant City, FL 33563 -
REGISTERED AGENT ADDRESS CHANGED 2023-04-30 608 W Dixie St, Plant City, FL 33563 -

Documents

Name Date
ANNUAL REPORT 2024-04-23
ANNUAL REPORT 2023-04-30
ANNUAL REPORT 2022-04-20
ANNUAL REPORT 2021-04-27
Domestic Profit 2020-11-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343823290 0420600 2019-02-28 32635 BROOKS HAWK LANE, WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-02-28
Emphasis P: FALL, L: FALL
Case Closed 2020-10-02

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2019-06-27
Current Penalty 21879.0
Initial Penalty 21879.0
Final Order 2019-08-02
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 32635 Brooks Hawk Lane- Employees in the process of decking the 5 in 12 slope (vertical to horizontal) roof, were exposed to an 19' 4" fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 2/28/19. All Framing Services Inc., was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1318339, citation number 1, item number 1 and was affirmed as a final order on 6/28/2018, with respect to a workplace located at 4374 Barbour Trail in Odessa, Fl. All Framing Services Inc., was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1280182, citation number 1, item number 1 and was affirmed as a final order on 2/26/2018, with respect to a workplace located at 12929 Payton St. in Odessa, Fl.
343183398 0420600 2018-05-23 STARKEY RANCH 4374 BARBOUR TRAIL, ODESSA, FL, 33556
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-05-23
Emphasis P: FALL, L: FALL
Case Closed 2020-10-02

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-05-29
Current Penalty 8536.0
Initial Penalty 8536.0
Final Order 2018-06-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Starkey Ranch - 4374 Barbour Trail- Employees in the process of decking the 6 in 12 slope (vertical to horizontal) roof, were exposed to an 20'8" fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 5/23/2018. All Framing Services Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1280182, citation number 1, item number 1 and was affirmed as a final order on 2/26/2018, with respect to a workplace located at 12929 Payton St. in Odessa, Fl.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2018-05-29
Abatement Due Date 2018-06-08
Current Penalty 4268.0
Initial Penalty 4268.0
Final Order 2018-06-29
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) Starkey Ranch - 4374 Barbour Trail- Employees in the process of framing activities were exposed to an 11'8" fall hazard, in that, fall protection equipment was not installed or utilized on the second floor, observed on or about 5/23/2018.
342801826 0420600 2017-11-30 STARKEY RANCH 12929 PAYTON ST., ODESSA, FL, 33556
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-11-30
Emphasis L: FALL, P: FALL
Case Closed 2020-10-02

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-12-22
Abatement Due Date 2018-01-22
Current Penalty 1901.5
Initial Penalty 3803.0
Final Order 2018-02-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 12929 Payton St.- Employees in the process of decking the 5 in 12 slope (vertical to horizontal) roof, were exposed to an 19'9" fall hazard, in that, fall protection equipment was not installed or utilized, observed on or about 11/30/2017.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2017-12-22
Abatement Due Date 2018-01-22
Current Penalty 1901.5
Initial Penalty 3803.0
Final Order 2018-02-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: (a) 12929 Payton St. - Employees were exposed to a fall hazard up to 10'9", in that, there was no hand rail on the enclosed stairs between the first and second floors, observed on or about 11/30/2017.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2017-12-22
Abatement Due Date 2018-01-22
Current Penalty 1901.5
Initial Penalty 3803.0
Final Order 2018-02-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: (a) 12929 Payton St. - Employees were exposed to a fall hazard up to 10'9", in that, there was no guardrail system installed on the second floor stairway landing, observed on or about 11/30/2017.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
4199171 Intrastate Non-Hazmat 2024-04-30 1 2023 1 1 Private(Property)
Legal Name ALL FRAMING SERVICES INC
DBA Name -
Physical Address 608 W DIXIE ST, PLANT CITY, FL, 33563-2362, US
Mailing Address 608 W DIXIE ST, PLANT CITY, FL, 33563-2362, US
Phone (813) 648-7576
Fax -
E-mail ALLFAMINGSERVICES@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 1
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 1
Vehicle Maintenance BASIC Roadside Performance measure value 4
Total Number of Vehicle Inspections for the measurement period 1
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 1
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Inspections

Unique report number of the inspection 3507009865
State abbreviation that indicates the state the inspector is from FL
The date of the inspection 2024-06-05
ID that indicates the level of inspection Walk-around
State abbreviation that indicates where the inspection occurred FL
Time weight of the inspection 2
Number of Out-Of-Service violations related to Driver 0
Number of Out-Of-Service violations related to vehicle 0
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 0
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit PETERBILT
License plate of the main unit P8612H
License state of the main unit FL
Vehicle Identification Number of the main unit 1NPSX7TX4HD350461
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Vehicle Maintenance BASIC inspection Y
Total number of BASIC violations 2
Number of Unsafe Driving BASIC violations 0
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 0
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 2
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2024-06-05
Code of the violation 39395A4EEUS
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 2
The description of a violation Emergency Equipment - Fire Extinguishers - unsecured
The description of the violation group Emergency Equipment
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-06-05
Code of the violation 3928D
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 2
The description of a violation Driver - Failed to inspect /use emergency equipment
The description of the violation group Emergency Equipment
The unit a violation is cited against Driver