Entity Name: | RUIZ CONSTRUCTION SERVICES INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
RUIZ CONSTRUCTION SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 12 Nov 2014 (10 years ago) |
Date of dissolution: | 24 Sep 2015 (10 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 24 Sep 2015 (10 years ago) |
Document Number: | P14000092535 |
FEI/EIN Number |
30-0846748
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 4504 SR 574 LOT 107, PLANT CITY, FL, 33563, US |
Mail Address: | 4504 SR 574 LOT 107, PLANT CITY, FL, 33563, US |
ZIP code: | 33563 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
RUIZ JOSE J | President | 4504 SR 574 LOT 107, PLANT CITY, FL, 33563 |
RUIZ JOSE J | Director | 4504 SR 574 LOT 107, PLANT CITY, FL, 33563 |
RUIZ JOSE J | Agent | 4504 SR 574 LOT 107, PLANT CITY, FL, 33563 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2015-09-24 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J16000208276 | LAPSED | 15-119-D3 | LEON | 2016-02-05 | 2021-03-24 | $41,837.04 | DFS DIVISION OF WORKERS COMPENSATION, 200 EAST GAINES STREET, TALLAHASSEE, FL 32399-4228 |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2015-09-24 |
ANNUAL REPORT | 2015-05-01 |
Domestic Profit | 2014-11-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340593557 | 0420600 | 2015-04-29 | OAKSTEAD PROFESSIONAL CENTER BUILDING #18 NARNIA WAY, LAND O LAKES, FL, 34638 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2015-05-07 |
Abatement Due Date | 2015-05-13 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines presented potential eye or face injury from physical agents. a) At the jobsite, employee was using an electric power-operated saw to cut plywood without eye protection being worn. The violation was observed on or about April 29, 2015. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2015-05-07 |
Abatement Due Date | 2015-05-13 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-05-19 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On the jobsite, employees were exposed to an approximate 10 ft fall hazard, in that, fall protection was not used while working from a 5 in 12 pitched roof. This violation was observed on or about April 29, 2015. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2015-05-07 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2015-05-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) At the jobsite, an employee was using an a-frame step ladder leaned against a wall to access overhead work. This violation was observed on or about April 29, 2015. |
Date of last update: 02 Apr 2025
Sources: Florida Department of State