Entity Name: | MAHET'S CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
MAHET'S CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 25 May 2018 (7 years ago) |
Document Number: | P18000048198 |
FEI/EIN Number |
83-0736601
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2706 HOLLY HILL GROVE, 1 RD, DAVENPORT, FL, 33837, US |
Mail Address: | 2706 HOLLY HILL GROVE, 1 RD, DAVENPORT, FL, 33837, US |
ZIP code: | 33837 |
County: | Polk |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ROBERTO MARTIN FRANCISCA | President | 2706 HOLLY HILL GROVE 1 RD, DAVENPORT, FL, 33837 |
ROBERTO MARTIN FRANCISCA | Agent | 2706 HOLLY HILL GROVE, DAVENPORT, FL, 33837 |
Name | Date |
---|---|
ANNUAL REPORT | 2024-05-01 |
ANNUAL REPORT | 2023-04-29 |
ANNUAL REPORT | 2022-03-19 |
ANNUAL REPORT | 2021-03-14 |
ANNUAL REPORT | 2020-03-10 |
ANNUAL REPORT | 2019-03-28 |
Domestic Profit | 2018-05-25 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345994511 | 0420600 | 2022-06-02 | HANDCART ROAD & MOONFLOWER AVENUE PASADENA POINT, LOT 06, BLOCK 01., WESLEY CHAPEL, FL, 33543 | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1900250 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Repeat |
Standard Cited | 19260501 B01 |
Issuance Date | 2022-06-07 |
Abatement Due Date | 2022-07-05 |
Current Penalty | 11602.0 |
Initial Penalty | 11602.0 |
Final Order | 2022-07-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. On or about June 02, 2022, an employee was using a pneumatic nail gun on a two-story roof to re-nail the roof sheathing, during which time he was not using fall protection; therefore exposing the employees to a fall hazards. MAHET'S CONSTRUCTION INC., was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 1926.501(b)(1), which was contained in OSHA inspection number 1442181, citation number 01, item number 001, and was affirmed as a final order on 10/30/2019, with respect to a workplace located at 5260 Donald Ross Rd Palm Beach Gardens, FL 33418. |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2019-10-30 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2022-06-03 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2020-04-09 |
Current Penalty | 3374.0 |
Initial Penalty | 6747.0 |
Final Order | 2020-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. On or about October 31, 2019, at the above addressed jobsite, an employee was exposed to a 20-foot fall hazard as he worked from a roof without the required fall protection. |