Search icon

AMERICAN FRAMING CONTRACTORS, INC. - Florida Company Profile

Company Details

Entity Name: AMERICAN FRAMING CONTRACTORS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

AMERICAN FRAMING CONTRACTORS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 15 Sep 2014 (11 years ago)
Date of dissolution: 25 Sep 2015 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (10 years ago)
Document Number: P14000076723
Address: 9900 S. THOMAS DRIVE, PANAMA CITY BEACH, FL, 32408
Mail Address: 1357 PERRY SIMS ROAD, WINDER, GA, 30680
ZIP code: 32408
County: Bay
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
FORD TRAVIS President 1357 PERRY SIMS ROAD, PANAMA CITY BEACH, FL, 32408
FORD GREG Vice President 1331 PERRY SIMS ROAD, PANAMA CITY BEACH, FL, 32408
FORD GREG Agent 9900 S. THOMAS DRIVE, PANAMA CITY BEACH, FL, 32408

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Documents

Name Date
Domestic Profit 2014-09-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339793580 0419700 2014-06-04 93 DUNE LAKES CIRCLE, SANTA ROSA BEACH, FL, 32459
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-06-04
Emphasis L: FALL, P: FALL
Case Closed 2014-10-10

Related Activity

Type Inspection
Activity Nr 983409
Safety Yes
Type Inspection
Activity Nr 983410
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2014-07-30
Current Penalty 3675.0
Initial Penalty 4900.0
Final Order 2014-10-07
Nr Instances 2
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a. On or about June 4, 2014, on the west side of a new construction condominium complex building, the employer did not ensure holes in walking working surfaces were covered; employees were not protected from fall hazards up to 10 feet 9 inches. b. On or about June 4, 2014, on the east side of a new construction condominium complex building, the employer did not ensure holes in walking working surfaces were covered; employees were not protected from a fall hazard of 14 feet.
Citation ID 02001
Citaton Type Other
Standard Cited 19261053 B05 I
Issuance Date 2014-07-30
Current Penalty 0.0
Initial Penalty 3500.0
Final Order 2014-10-07
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder: a. On or about June 4, 2014, employees framing a new construction condominium complex were using a job made ladder that was not one-quarter of the working length of the ladder, exposing employees to a 9 feet 8 inch fall hazard.
339656738 0419700 2014-04-01 101A ST. JOHN'S CROSSING, PANAMA CITY BEACH, FL, 32407
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2014-04-01
Emphasis L: FALL
Case Closed 2014-06-26

Related Activity

Type Complaint
Activity Nr 878256
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-05-01
Abatement Due Date 2014-05-28
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a. On or about April 1, 2014, on the south side of the structure, three employees building a frame structure for a condominium complex were not protected from a 9 feet 1 inch fall hazard by the use of a personal fall arrest system.
339602278 0419700 2014-02-27 5400 S. WILLIAMSON BLVD., PORT ORANGE, FL, 32128
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-03-17
Emphasis L: FALL
Case Closed 2014-07-10

Related Activity

Type Complaint
Activity Nr 874047
Safety Yes
Type Inspection
Activity Nr 962314
Safety Yes
Type Inspection
Activity Nr 960230
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2014-05-07
Abatement Due Date 2014-05-27
Current Penalty 0.0
Initial Penalty 5390.0
Final Order 2014-06-03
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards: a. On or about February 24, 2014, employees were exposed to struck-by hazards because the installed wooden trusses had not been adequately braced to prevent accidental collapse of the structure.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-05-07
Abatement Due Date 2014-05-19
Current Penalty 3000.0
Initial Penalty 10780.0
Final Order 2014-06-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line American Framing Contractors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.501 (b)(13)), which was contained in OSHA inspection number 559958 citation number 1 item number 1 and was affirmed as a final order on 10/03/2012, with respect to a workplace located at Stone Ridge Park Boulevard (The Grand Reserve Apartments) Pike Road, AL. 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about February 10, 2014, an employee setting trusses was not protected from a 9 feet fall hazard from the top plate to the breezeway. b. On or about March 10, 2014, two employees were hammering in nails on Building 5 and were not protected from a 29 feet fall hazard from the top plate to the ground.
Citation ID 03001
Citaton Type Other
Standard Cited 19261053 A03 I
Issuance Date 2014-05-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(a)(3)(i): Rungs, cleats, and/or steps of portable ladders (except step stools) and/or fixed ladders (including individual-rung/step ladders) were spaced less than 10 inches (25 cm) apart or more than 14 inches (36 cm) apart, as measured: a. On or about February 24, 2014, an employee was using a job-made ladder with rungs spaced at 17 inches on center.

Date of last update: 01 Apr 2025