Search icon

BATEMAN AF CONTRACTORS INC - Florida Company Profile

Company Details

Entity Name: BATEMAN AF CONTRACTORS INC
Jurisdiction: FLORIDA
Filing Type: Foreign Profit
Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 05 Apr 2016 (9 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: REVOKED FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: F16000001590
FEI/EIN Number 473608477

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5904 Peachtree Corners East, Norcross, GA, 30071, US
Mail Address: 5904 PEACHTREE CORNERS RD EAST, NORCROSS, GA, 30071, US
Place of Formation: GEORGIA

Key Officers & Management

Name Role Address
BATEMAN KENNETH W Chairman 3303 VINTAGE CIRCLE SE, SMYRNA, GA, 30080
BATEMAN KENNETH W President 3303 VINTAGE CIRCLE SE, SMYRNA, GA, 30080
BATEMAN KENNETH W Secretary 3303 VINTAGE CIRCLE SE, SMYRNA, GA, 30080
FORD TRAVIS Treasurer 5904 PEACHTREE CORNERS RD EAST, SMYRNA, GA, 30080
FORD TRAVIS L Agent 1536 ERWIN DR, PENSACOLA, FL, 32514

Events

Event Type Filed Date Value Description
REVOKED FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-02-12 5904 Peachtree Corners East, Norcross, GA 30071 -

Documents

Name Date
ANNUAL REPORT 2018-02-12
ANNUAL REPORT 2017-01-10
Foreign Profit 2016-04-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343351169 0419700 2018-07-31 9095 AIRWAY DR. THE PARKSIDE GRAND, PENSACOLA, FL, 32514
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2018-08-01
Emphasis P: FALL, L: FALL
Case Closed 2018-09-12

Related Activity

Type Inspection
Activity Nr 1335109
Safety Yes
Type Inspection
Activity Nr 1335082
Safety Yes
Type Inspection
Activity Nr 1335076
Safety Yes
Type Inspection
Activity Nr 1335094
Safety Yes
Type Inspection
Activity Nr 1335136
Safety Yes
Type Inspection
Activity Nr 1335105
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-08-21
Abatement Due Date 2018-08-31
Current Penalty 2328.6
Initial Penalty 3881.0
Final Order 2018-09-11
Nr Instances 3
Nr Exposed 13
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 9095 Airway Drive, The Parkside Grand, Pensacola, Florida: On or about July 31, 2018 and at times prior; the controlling employer failed to ensure subcontracted crew (Mariano Castro Silva) performing framing activties on Building 4 had and were using fall protection exposing them to a fall hazard of up to 20 feet to the ground below. b) At 9095 Airway Drive, The Parkside Grand, Pensacola, Florida: On or about July 31, 2018 and at times prior; the controlling employer failed to ensure subcontracted crew (Pablo Garcia) performing framing activties on Building 8 had and were using fall protection exposing them to a fall hazard of up to 19.1 feet to the ground below. c) At 9095 Airway Drive, The Parkside Grand, Pensacola, Florida: On or about July 31, 2018 and at times prior; the controlling employer failed to ensure subcontracted crew (Antonio Juarez) performing roofing activties on Building 9 had and were using fall protection exposing them to a fall hazard of up to 30 feet to the ground below.
Citation ID 01002
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2018-08-21
Abatement Due Date 2018-08-31
Current Penalty 1663.2
Initial Penalty 2772.0
Final Order 2018-09-11
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees were exposed to struck-by and crush hazards from operating powered industrial trucks without wearing the seatbelt: a) At 9095 Airway Drive, The Parkside Grand Bldg. 4, Pensacola, Florida: On or about July 31, 2018 and at times prior; the controlling employer failed to ensure subcontracted (Mariano Castro Silva) employees operating powered industrial trucks were wearing seatbelts exposing them employees to crush hazards. b) At 9095 Airway Drive, The Parkside Grand Bldg. 9, Pensacola, Florida: On or about July 31, 2018 and at times prior; the controlling employer failed to ensure subcontracted (Antonio Juarez) employees operating powered industrial trucks were wearing seatbelts exposing them employees to crush hazards.

Date of last update: 01 Apr 2025

Sources: Florida Department of State