Search icon

DWC CONTRACTING, INC - Florida Company Profile

Company Details

Entity Name: DWC CONTRACTING, INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

DWC CONTRACTING, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 15 Dec 2004 (20 years ago)
Date of dissolution: 25 Sep 2015 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (10 years ago)
Document Number: P04000168260
FEI/EIN Number 202011206

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 364 SW STERLING TERRRACE, HIGH SPRINGS, FL, 32643
Mail Address: 364 SW STERLING TERRRACE, HIGH SPRINGS, FL, 32643
ZIP code: 32643
County: Alachua
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TERRY LISA G Treasurer 364 SW STERLING TERRACE, HIGH SPRINGS, FL, 32643
TERRY LISA G Director 364 SW STERLING TERRACE, HIGH SPRINGS, FL, 32643
TERRY CRAIG Agent 364 SW STERLING TERRACE, HIGH SPRINGS, FL, 32643
TERRY CRAIG President 364 SW STERLING TERRACE, HIGH SPRINGS, FL, 32643
TERRY CRAIG Director 364 SW STERLING TERRACE, HIGH SPRINGS, FL, 32643
TERRY LISA G Secretary 364 SW STERLING TERRACE, HIGH SPRINGS, FL, 32643

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Documents

Name Date
ANNUAL REPORT 2014-04-28
ANNUAL REPORT 2013-04-18
ANNUAL REPORT 2012-04-30
ANNUAL REPORT 2011-04-28
ANNUAL REPORT 2010-05-03
ANNUAL REPORT 2009-04-27
ANNUAL REPORT 2008-04-29
ANNUAL REPORT 2007-04-02
ANNUAL REPORT 2006-06-15
Domestic Profit 2004-12-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340046804 0419700 2014-10-28 7827 SW 79TH DRIVE, GAINESVILLE, FL, 32608
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-28
Emphasis L: FALL, P: FALL
Case Closed 2019-01-18

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2014-11-17
Current Penalty 4620.0
Initial Penalty 4620.0
Final Order 2015-02-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: a. On or about October 29, 2014 west the east side of the structure, an employee used a wooden job made ladder without filler blocks inserted between the rungs to support the cleats, exposing himself to a 9-foot 5-inch fall hazard. Among other methods, one feasible and acceptable method to correct this hazard is to, but not limited to the following: (1) conform to the American National Standard Institute (ANSI) A14.4-1992, section 4.5.2.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-11-17
Current Penalty 4620.0
Initial Penalty 4620.0
Final Order 2015-02-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about October 29, 2014, an employee used a wooden ladder to access a structure improperly, in that the ladder did not extend 3 feet over the edge nor was secured from slippage, exposing the employee to a fall hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260100 A
Issuance Date 2014-11-17
Current Penalty 9240.0
Initial Penalty 9240.0
Final Order 2015-02-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about October 29, 2014, two employees performing framing operations were not wearing protective helmets, exposing themselves to overhead hazards. The DWC Contracting, Incorporated was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.100(a), which was contained in OSHA inspection number 951010, citation number 01, item number 001 and was affirmed as a final order on January 8, 2013, with respect to a workplace located at SW 80 Place, Gainesville, Florida 32608.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2014-11-17
Current Penalty 9240.0
Initial Penalty 9240.0
Final Order 2015-02-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 29, 2014, on top of a structure, an employee performing framing operations was not protected from a 9-foot 5-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. The DWC Contracting, Incorporated was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 951010, citation number 01, item number 003 and was affirmed as a final order on January 8, 2013, with respect to a workplace located at SW 80 Place, Gainesville, Florida 32608.
Citation ID 03001
Citaton Type Other
Standard Cited 19260023
Issuance Date 2014-11-17
Abatement Due Date 2014-12-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-05
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.23: First aid services and provisions for medical care were not made available by the employer for every employee: a. On or about October 29, 2014, at the jobsite, first aid was not readily available for employee usage in the event of an emergency.
339510109 0419700 2013-12-05 SW 80 PLACE, GAINESVILLE, FL, 32608
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-12-05
Emphasis L: FALL, L: EISAOF, P: FALL
Case Closed 2022-06-08

Related Activity

Type Inspection
Activity Nr 951019
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2013-12-06
Current Penalty 0.0
Initial Penalty 4200.0
Final Order 2014-01-03
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about December 5, 2013, on top of a structure, three employees performing framing operations were not wearing hard hats, exposing themselves to an overhead hazard such as being hit being hit by flying trusses.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-12-06
Current Penalty 3150.0
Initial Penalty 4200.0
Final Order 2014-01-03
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about December 5, 2013, on top of a structure, an employee using a Hitachi Pneumatic air nail gun was not wearing safety glasses, exposing himself to being hit by nails or flying debris.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2013-12-06
Current Penalty 3150.0
Initial Penalty 4200.0
Final Order 2014-01-03
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about December 5, 2013, on top of a structure, three employees performing framing operations were not protected from an 9-foot 3-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection.
311821706 0419700 2009-05-05 4100 NW 37TH PLACE, GAINESVILLE, FL, 32605
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2009-05-05
Emphasis S: FALL FROM HEIGHT, S: STRUCK-BY, S: POWERED IND VEHICLE, L: FALL, S: COMMERCIAL CONSTR
Case Closed 2010-05-07

Related Activity

Type Complaint
Activity Nr 207188830
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260501 B11
Issuance Date 2009-05-22
Abatement Due Date 2009-06-11
Current Penalty 1670.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 2
Gravity 03
Citation ID 01002
Citaton Type Other
Standard Cited 19261053 B04
Issuance Date 2009-05-22
Abatement Due Date 2009-05-28
Current Penalty 250.0
Initial Penalty 900.0
Nr Instances 1
Nr Exposed 1
Gravity 02
310035340 0419700 2008-02-28 2445 SOUTHWEST 76TH ST, GAINESVILLE, FL, 32606
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2008-02-29
Emphasis S: POWERED IND VEHICLE, S: RESIDENTIAL CONSTR, L: FALL, S: STRUCK-BY, S: FALL FROM HEIGHT
Case Closed 2008-09-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2008-03-14
Abatement Due Date 2008-03-19
Current Penalty 1000.0
Initial Penalty 1250.0
Nr Instances 1
Nr Exposed 1
Gravity 03
Citation ID 01002
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2008-03-14
Abatement Due Date 2008-03-19
Current Penalty 1000.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2008-03-14
Abatement Due Date 2008-03-19
Current Penalty 1325.0
Initial Penalty 2500.0
Nr Instances 3
Nr Exposed 6
Gravity 10
Citation ID 02002
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2008-03-14
Abatement Due Date 2008-04-30
Nr Instances 1
Nr Exposed 9
Gravity 01