Entity Name: | PREFERRED ROOFING AND CONSTRUCTION, LLC |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Limited Liability Co.
PREFERRED ROOFING AND CONSTRUCTION, LLC is structured as a Limited Liability Company (LLC), a common business structure that offers its members limited liability protection, separating their personal assets from the company's debts and obligations. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 04 Dec 2009 (15 years ago) |
Date of dissolution: | 27 Sep 2013 (12 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 27 Sep 2013 (12 years ago) |
Document Number: | L09000115774 |
FEI/EIN Number |
271420452
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2332 DUNN AVE, JACKSONVILLE, FL, 32218, US |
Mail Address: | 2332 DUNN AVE, JACKSONVILLE, FL, 32218, US |
ZIP code: | 32218 |
County: | Duval |
Place of Formation: | FLORIDA |
Name | Role |
---|---|
WJC INVESTMENTS, INC. | Managing Member |
KEVIN S. GREEN, INC. | Agent |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2013-09-27 | - | - |
LC AMENDMENT | 2010-12-13 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J13001406181 | LAPSED | 16-2013-CA-005588 | FOURTH JUDICIAL CIRCUIT, DUVAL | 2013-09-04 | 2018-09-20 | $20,204.25 | L&W SUPPLY CORPORATION D/B/A SEACOAST SUPPLY, 550 WEST ADAMS STREET, DEPT. 174, CHICAGO, IL 60661-3676 |
J13001604132 | LAPSED | 16-2013-CA-005588 | FOURTH JUDICIAL CIRCUIT | 2013-09-04 | 2018-11-06 | $20,204.25 | L&W SUPPLY CORPORATION, 27901 QUINN STREET, BONITA SPRINGS, FL 34135 |
J13001524876 | LAPSED | 13-2408-CI-11 | CIR CT 6TH JUD CIR PINELLAS CO | 2013-07-31 | 2018-10-15 | $71,499.41 | AMERICAN BUILDERS & CONTRACTORS SUPPLY CO., INC., 6944 N US HWY 41, APOLLO BEACH, FL 33572 |
J13000511163 | LAPSED | 12-12484-CI-13 | CIR CT 6TH JUD CIR PINELLAS CO | 2013-01-31 | 2018-02-28 | $42096.79 | SRS ACQUISITION CORPORATION OF DELAWARE, D/B/A SUNCOAST ROOFERS SUPPLY, INC., TAMPA, FL 33613 |
Name | Date |
---|---|
ANNUAL REPORT | 2012-04-23 |
ANNUAL REPORT | 2011-02-15 |
LC Amendment | 2010-12-13 |
ANNUAL REPORT | 2010-01-25 |
Florida Limited Liability | 2009-12-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334839792 | 0419700 | 2012-06-22 | 13853 SOFT WIND TRAIL, JACKSONVILLE, FL, 32224 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2012-07-19 |
Abatement Due Date | 2012-08-09 |
Current Penalty | 775.0 |
Initial Penalty | 2380.0 |
Final Order | 2012-08-17 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about June 22, 2012, employees using pneumatic nail guns during roofing operations were not wearing safety glasses, exposing employees to the hazard of being struck in the eye by flying debris. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260307 D01 |
Issuance Date | 2012-07-19 |
Current Penalty | 775.0 |
Initial Penalty | 1517.25 |
Final Order | 2012-08-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.307(d)(1): "Guarding." Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes: a. On or about June 22, 2012, the ridgid compressor did not have a guard on the pulley, exposing employees to a caught in hazard. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2012-07-19 |
Current Penalty | 775.0 |
Initial Penalty | 2023.0 |
Final Order | 2012-08-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a. On or about June 22, 2012, on the 5/12 pitch roof, employees installing shingles were not protected from an 8 feet fall hazard by the use of a fall protection system. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2012-07-19 |
Current Penalty | 775.0 |
Initial Penalty | 2023.0 |
Final Order | 2012-08-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about June 22, 2012,the ladder used to access the roof did not extend three feet above the landing, exposing emplyees to an 8 feet fall hazard. |
Date of last update: 02 May 2025
Sources: Florida Department of State