Entity Name: | C.W. STRICKLAND, INC. STATE GENERAL CONTRACTOR |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
C.W. STRICKLAND, INC. STATE GENERAL CONTRACTOR is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 02 Oct 1992 (33 years ago) |
Date of dissolution: | 06 May 2020 (5 years ago) |
Last Event: | ADMIN DISSOLUTION FOR REGISTERED AGENT |
Event Date Filed: | 06 May 2020 (5 years ago) |
Document Number: | V68967 |
FEI/EIN Number |
650362577
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 6760 NW 138th PL, Chiefland, FL, 32626, US |
Mail Address: | 6760 NW 138th PL, Chiefland, FL, 32626, US |
ZIP code: | 32626 |
County: | Levy |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
MARTIN MICHAEL A | Vice President | 6760 NW 138TH PL, CHIEFLAND, FL, 32626 |
MCINTYRE KERRY | Agent | 6760 NW 138TH PL, CHIEFLAND, FL, 32626 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR REGISTERED AGENT | 2020-05-06 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2019-08-02 | 6760 NW 138th PL, Chiefland, FL 32626 | - |
CHANGE OF MAILING ADDRESS | 2019-08-02 | 6760 NW 138th PL, Chiefland, FL 32626 | - |
REINSTATEMENT | 2018-10-15 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2018-09-28 | - | - |
AMENDMENT | 2016-12-13 | - | - |
REINSTATEMENT | 1997-05-12 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 1996-08-23 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J24000490324 | ACTIVE | 17-189-D4-OPA | LEON COUNTY | 2021-04-16 | 2029-08-01 | $406,814.66 | DFS DIVISION OF WORKERS COMPENSATION, 200 EAST GAINES STREET, TALLAHASSEE, FL 32399-4228 |
J19000587988 | LAPSED | 2017-32190-CICI | CIRCUIT, VOLUSIA | 2019-09-06 | 2024-09-11 | $317261.11 | STRATUS CONSTRUCTION AND ROOFING, LLC, C/O JASON R. HAWKINS, SOUTH MILHAUSEN PA, 1000 LEGION PLACE, SUITE #1200, ORLANDO, FL 32801 |
J19000431153 | LAPSED | 18-CA-010149 | HILSBOROUGH CIRCUIT COURT | 2019-06-04 | 2024-06-24 | $93,654.94 | BEACON SALES ACQUISITION, INC., 505 HUNTMAR PARK DR., 300, HERNDON, VA 20170 |
J18000495952 | LAPSED | 2018 30468 CI | 7TH JUDICIAL CIRCUIT VOLUSIA | 2018-07-16 | 2023-07-17 | $16,842.39 | AVANTE AT ORMOND BEACH, INC., 170 NORTH KINGS ROAD, #2305, ORMOND BEACH, FL 32174 |
J11000656954 | TERMINATED | 2010-SC-004409 | LAKE COUNTY COURT | 2011-09-27 | 2016-10-11 | $697.88 | CITY ELECTRIC CUPPLY COMPANY, P.O. BOX 609521, ORLANDO, FLA 32860-9521 |
Name | Date |
---|---|
Admin. Diss. for Reg. Agent | 2020-05-06 |
Reg. Agent Resignation | 2019-12-11 |
Off/Dir Resignation | 2019-12-11 |
ANNUAL REPORT | 2019-08-02 |
REINSTATEMENT | 2018-10-15 |
ANNUAL REPORT | 2017-04-25 |
Amendment | 2016-12-13 |
ANNUAL REPORT | 2016-05-15 |
ANNUAL REPORT | 2015-03-01 |
ANNUAL REPORT | 2014-03-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342086873 | 0419700 | 2017-02-06 | 1242 S RIDGEWOOD AVE, DAYTONA BEACH, FL, 32114 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2017-04-04 |
Current Penalty | 2662.0 |
Initial Penalty | 3803.0 |
Final Order | 2017-04-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system: a) On or about February 6, 2017, three (3) employees tearing off old roofing shingles on a 4:12 pitch roof were not protected from falling 20 feet to the ground by the use of a guardrail system, safety nest system or personal fall arrest system. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-01-19 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2022-09-02 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2017-02-22 |
Current Penalty | 2535.0 |
Initial Penalty | 5070.0 |
Final Order | 2017-03-16 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment are not used when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a. On or about January 19, 2017, two employees were using pneumatic air guns performing roofing activities without the use of safety glasses. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-02-22 |
Current Penalty | 2535.0 |
Initial Penalty | 5070.0 |
Final Order | 2017-03-16 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about January 19, 2017, on a 3:12 pitch roof, employees performing re-roofing operations, were not protected from a 8 foot fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260020 B01 |
Issuance Date | 2017-02-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-03-16 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On or about January 19, 2017, at the worksite, a safety and health program had not been initiated and maintained which addressed the following basic elements: 1. Management Commitment and Leadership a. Policy statement: goals established, issued, and communicated to employees. b. Program Reviewed Annually. c. Participation in safety meetings, inspections; agenda item in meetings. d. Adequate commitment of resources. e. Safety rules and procedures incorporated into site operations. f. Management observations of safety rules. 2. Assignment of Responsibility a. Safety designee on site, knowledgeable, and accountable. b. Supervisors' (including foremen) safety and health responsibilities understood. c. Employees adherence to safety rules. 3. Identification and Control of Hazards a. Periodic site inspection program involving supervisors. b. Preventive controls in place (PPE, Maintenance, Engineering Controls). c. Action taken to address hazards. d. Safety Committee, where appropriate. e. Technical reference materials available. 4. Training and Education a. Supervisors receive basic safety and health training. b. Specialized training taken when needed. c. Existence of an employee training program, which is ongoing and effective. 5. Recordkeeping and Hazard Analysis |
Date of last update: 02 Apr 2025