Search icon

A & R STUCCO, INC. - Florida Company Profile

Company Details

Entity Name: A & R STUCCO, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

A & R STUCCO, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 13 Mar 1992 (33 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: V21284
FEI/EIN Number 593110748

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1541 E. SHELL POINTE RD., RUSKIN, FL, 33570
Mail Address: 1541 E. SHELL POINTE RD., RUSKIN, FL, 33570
ZIP code: 33570
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
Chavez MINDY M Vice President PO BOX 222, RUSKIN, FL, 33575
RODRIGUEZ CELINDA Secretary 1541 E. SHELL POINT RD., RUSKIN, FL, 33570
RODRIGUEZ ARNULFO JR President 1541 E. SHELL POINT RD., RUSKIN, FL, 33570
RODRIGUEZ ARNULFO JR Agent 1541 E. SHELL POINT RD., RUSKIN, FL, 33570

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
REINSTATEMENT 2015-11-17 - -
REGISTERED AGENT NAME CHANGED 2015-11-17 RODRIGUEZ, ARNULFO, JR -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -
REINSTATEMENT 2013-10-10 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2012-08-28 1541 E. SHELL POINTE RD., RUSKIN, FL 33570 -
REGISTERED AGENT ADDRESS CHANGED 2012-08-28 1541 E. SHELL POINT RD., RUSKIN, FL 33570 -
CHANGE OF MAILING ADDRESS 2012-08-28 1541 E. SHELL POINTE RD., RUSKIN, FL 33570 -
CANCEL ADM DISS/REV 2004-10-20 - -

Documents

Name Date
ANNUAL REPORT 2018-04-11
ANNUAL REPORT 2017-01-09
ANNUAL REPORT 2016-03-30
REINSTATEMENT 2015-11-17
ANNUAL REPORT 2014-03-21
REINSTATEMENT 2013-10-10
ANNUAL REPORT 2012-08-28
ANNUAL REPORT 2011-03-16
ANNUAL REPORT 2010-04-16
ANNUAL REPORT 2009-04-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344172978 0420600 2019-07-17 16541 S. US HIGHWAY 301, SUN CITY CENTER, FL, 33573
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-07-17
Emphasis L: FALL, P: FALL
Case Closed 2020-11-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-02-10
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about July 17, 2019, at the southeast side of the commercial building, the second level of the supported scaffold used by employees to scratch stucco surface on front parapet wall was not fully planked, exposing employees to a 12 foot fall hazard. b) On or about July 17 2019, at the northeast side of the commercial building, the second level of the supported scaffold used by employees to apply plaster stucco on the wall was not fully planked, exposing the employees to a 10 foot fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-02-10
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about July 17, 2019, at the southeast side of the commercial building, the tubular framed scaffolding system 2 tiers high being used by employees plastering stucco was missing mudsills in all frames, exposing employees to fall, collapse and struck by hazards. b) On or about July 17, 2019, at the northeast side of the commercial building, the tubular framed scaffolding system 2 tiers high being used by employees plastering stucco was missing mudsills in all frames, exposing employees to fall, collapse and struck by hazards.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-02-10
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) On or about July 17, 2019, at the southeast northeast sides of the commercial building, employees used the tubular components of the scaffold to access the two levels of the frame scaffold. b) On or about July 17, 2019, at the northeast sides of the commercial building, employees used the tubular components of the scaffold to access the two levels of the frame scaffold.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-02-10
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a) On or about July 17, 2019, at the southeast side of the commercial building, the north end of the second level of the supported scaffold used by employees to plaster stucco on the wall had no guardrail system installed, exposing the em employees to a 12 foot fall hazard. b) On or about July 17, 2019, at the northeast side of the commercial building, the north end of the second level of the supported scaffold used by employees to plaster stucco on the wall had no guardrail system installed, exposing the employees to a 10 foot fall hazard.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-02-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about July 17, 2019 at the southeast and northeast sides of a commercial building, employees working on a supported scaffold while plastering stucco on the exterior wall had not been trained on the hazards of the scaffolding system.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-02-10
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in: (a) On or about July 17, 2019, employees required to erect and dismantle masonry scaffold systems for work crews applying stucco cement to outside of a single story commercial building.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-02-10
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On July 17, 2019, at the east side of the commercial building; for employees handling hazardous materials such as but not limited to stucco cement.
Citation ID 02002
Citaton Type Other
Standard Cited 19260051 F03 III
Issuance Date 2020-01-16
Abatement Due Date 2020-02-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-02-10
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.51(f)(3)(iii): Hand soap or similar cleansing agents was not provided: a) On or about July 17, 2019, for employees without hand protection, mixing, applying and scratching stucco cement.
308763721 0420600 2005-04-06 510 S. MOODY AVE., TAMPA, FL, 33609
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2005-04-06
Emphasis L: FALL
Case Closed 2006-01-10

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2005-05-03
Abatement Due Date 2005-05-06
Current Penalty 1500.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2005-05-03
Abatement Due Date 2005-05-06
Current Penalty 1500.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2005-05-03
Abatement Due Date 2005-05-06
Current Penalty 1500.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2005-05-03
Abatement Due Date 2005-05-06
Current Penalty 1500.0
Initial Penalty 2000.0
Nr Instances 2
Nr Exposed 2
Gravity 10
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2005-05-03
Abatement Due Date 2005-05-06
Current Penalty 1500.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 2
Gravity 10
308465251 0420600 2004-12-08 VICTORIA PARK TOWNHOMES/ 510 S. MOODY AVE., TAMPA, FL, 33609
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2004-12-08
Emphasis L: FALL
Case Closed 2005-03-22

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260453 B02 V
Issuance Date 2005-01-12
Abatement Due Date 2005-01-18
Current Penalty 3000.0
Initial Penalty 4000.0
Nr Instances 1
Nr Exposed 1
Gravity 10
306998519 0420600 2003-09-09 CASABELLA CIRCLE TOWNHOMES 601 DELEON ST., TAMPA, FL, 33609
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2003-09-09
Emphasis L: FALL, S: CONSTRUCTION
Case Closed 2003-10-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2003-09-11
Abatement Due Date 2003-09-16
Current Penalty 1125.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 3
Gravity 10
Citation ID 02001
Citaton Type Other
Standard Cited 19260021 B02
Issuance Date 2003-09-11
Abatement Due Date 2003-09-16
Nr Instances 1
Nr Exposed 3
Gravity 01

Date of last update: 02 Apr 2025

Sources: Florida Department of State