Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-07-22
|
Case Closed |
2015-10-08
|
Related Activity
Type |
Complaint |
Activity Nr |
829200 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-11-21 |
Current Penalty |
1200.0 |
Initial Penalty |
2400.0 |
Final Order |
2013-12-16 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and (a) for the establishment located at 2401 Airport Road Plant City (FL), Drill Press 12 Speed Model #793.12889307, Serial #503906 did not have a guard available for when an employee used the machine to make adjustments to metal parts, on or about July 19th, 2013. (b) for the establishment located at 2401 Airport Road Plant City (FL), Enco Milling Machine did not have a guard available for when an employee was using the machine to widen the hole of a metal part, on or about July 19th, 2013. (c) for the establishment located at 2401 Airport Road Plant City (FL), Bridgeport Milling Machine did not have a guard available for when an employee used the machine to make adjustments to metal parts, on or about July 19th, 2013. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A02 |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-04 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-12-16 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: (a) for the establishment located at 2401 Airport Road Plant City (FL), while employees were using Enco, Model 160-0201 bench grinder without guards, on or about July 19, 2013. (b) for the establishment located at 2401 Airport Road Plant City (FL), while employees were using a WT 8" bench grinder, Model 1200.225 , on or about July 19, 2013. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-04 |
Current Penalty |
0.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) for the establishment located at 2401 Airport Road Plant City (FL), while employees were using Enco bench grinder, Model 160-0201 without a work rest, on or about July 19, 2013. (b) for the establishment located at 2401 Airport Road Plant City (FL), while employees were using a WT 8" bench grinder, Model 1200.225 without a workrest, on or about July 19, 2013. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-04 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) at 2401 Airport Road Plant City (FL), employees performing various job tasks utilizing a Bridgeport Milling Machine, Series I and a Enco Milling Machine with exposed moving parts located in the head area, as observed on or about July 19, 2013. |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100303 B07 IV |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(iv): Where there were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) for the Enco Lathe Model 110-1351 located in the production area of B & M Industries at 2401 Airport Road in Plant City (FL), as observed on or about 07/19/2013. The emergency stop button had been damaged and removed preventing its use. |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) at 2401 Airport Road Plant City (FL), where employees were using a Bridgeport Milling Machine, Series I where the strain relief to the power cord was damaged, on or about July 19, 2013. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) at 2401 Airport Road Plant City (FL), where employees were a sandblasting procedure with the use of "Sunniland Sunscapes Patio Leveling Sand" as media while prepping metal pieces before assembly, as observed on or about July 19th, 2013. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: (a) at 2401 Airport Road Plant City (FL), where employees were using sandblasting media "Sunniland Sunscapes Patio Leveling Sand" while prepping metal pieces before assembly, as observed on or about July 19th, 2013. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100138 A |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion: (a) at 2401 Airport Road Plant City (FL), where an employee was using gloves that were damaged with large tears in the fingers and along the inside of the hand to prep metal pieces for welding, on or about July 19th, 2013. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100094 A04 I A |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.94(a)(4)(i)(a): When dust leaks were noted, repairs were not made as soon as possible: a) for the establishment located at 2401 Airport Road Plant City (FL), an employee was using a sandblasting cabinet with a cyclone filtration system with a damaged dust collection hose that had multiple openings allowing dust to come out of the equipment, on or about July 19th, 2013. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) for the establishment located at 2401 Airport Road Plant City (FL), where a relocatable power strip was being used as permanent wiring to power lamps installed on the Bridgeport and Enco Milling Machines, on or about July 19th, 2013. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100303 C03 I |
Issuance Date |
2013-11-21 |
Abatement Due Date |
2013-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-12-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: a) for the establishment located at 2401 Airport Road Plant City (FL), where employees were using an altered electrical cord that was coming directly from an electrical panel to a Bridgeport Milling Machine for supplying power by splicing the power cord of the milling machine and taping the two connections together, on or about July 19th, 2013. |
|
|