Search icon

PENSACOLA METAL FABRICATION, INC. - Florida Company Profile

Company Details

Entity Name: PENSACOLA METAL FABRICATION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PENSACOLA METAL FABRICATION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Mar 1991 (34 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 25 Oct 1996 (29 years ago)
Document Number: S35472
FEI/EIN Number 593048424

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 9320 UNTREINER AVE., PENSACOLA, FL, 32534
Mail Address: 9320 UNTREINER AVE., PENSACOLA, FL, 32534
ZIP code: 32534
County: Escambia
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SMITH DAVID A Vice President 3875 Durango Dr, PENSACOLA, FL, 32504
SMITH LARRY D President 11584 DUELING OAKS DR., PENSACOLA, FL, 32514
SMITH LARRY D Agent 11584 Dueling Oaks Dr, PENSACOLA, FL, 32514

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2019-04-03 11584 Dueling Oaks Dr, PENSACOLA, FL 32514 -
REINSTATEMENT 1996-10-25 - -
CHANGE OF PRINCIPAL ADDRESS 1996-10-25 9320 UNTREINER AVE., PENSACOLA, FL 32534 -
CHANGE OF MAILING ADDRESS 1996-10-25 9320 UNTREINER AVE., PENSACOLA, FL 32534 -
REGISTERED AGENT NAME CHANGED 1996-10-25 SMITH, LARRY D -
ADMIN DISSOLUTION FOR ANNUAL REPORT 1994-08-26 - -

Documents

Name Date
ANNUAL REPORT 2024-04-01
ANNUAL REPORT 2023-02-17
ANNUAL REPORT 2022-02-07
ANNUAL REPORT 2021-05-06
ANNUAL REPORT 2020-01-29
ANNUAL REPORT 2019-04-03
ANNUAL REPORT 2018-04-20
ANNUAL REPORT 2017-01-11
ANNUAL REPORT 2016-03-08
ANNUAL REPORT 2015-02-10

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PURCHASE ORDER AWARD N6883609P3145 2009-09-04 2009-09-18 2009-09-18
Unique Award Key CONT_AWD_N6883609P3145_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 4185.00
Current Award Amount 4185.00
Potential Award Amount 4185.00

Description

Title PROVIDE ALL LABOR AND MATERIALS TO
NAICS Code 332322: SHEET METAL WORK MANUFACTURING
Product and Service Codes Z299: MAINT, REP/ALTER/ALL OTHER

Recipient Details

Recipient PENSACOLA METAL FABRICATION, INC.
UEI V4ENJE93ZGZ4
Legacy DUNS 623372505
Recipient Address 9320 UNTREINER AVE, PENSACOLA, ESCAMBIA, FLORIDA, 325341889, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347418717 0418600 2024-04-15 9320 UNTREINER AVE, PENSACOLA, FL, 32534
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2024-04-17
Emphasis N: CHROME6
Case Closed 2024-10-21

Related Activity

Type Referral
Activity Nr 2144446
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2024-07-09
Abatement Due Date 2024-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-06
Nr Instances 1
Nr Exposed 20
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1):Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met and which also includes the information required in (e)(1)(i)-(e)(1)(ii). a) Facility: On or about April 15, 2024: Employer did not have a written hazard communication program detailing the hazards of chemicals such as but not limited to welding gases, metals and cleaners used in the facility.
Citation ID 01001B
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2024-07-09
Abatement Due Date 2024-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-06
Nr Instances 1
Nr Exposed 20
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Facility wide; On or about April 15, 2024, and at times prior thereto the employer exposed employees to hazardous chemicals and substances that include but are not limited to welding gases, metals and cleaners without providing information and training on these chemicals and substances they are required to work around as required by the standard.
347361701 0418600 2024-03-20 9320 UNTREINER AVE, PENSACOLA, FL, 32534
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-03-21
Emphasis L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
Case Closed 2024-09-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2024-07-09
Abatement Due Date 2024-07-23
Current Penalty 2766.0
Initial Penalty 4610.0
Final Order 2024-09-09
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards. a) Main Shop; On or about March 20, 2024 and times prior employees were exposed to crush hazards in that the employer allowed employees to operate powered industrial trucks which did not have seatbelts installed.
Citation ID 02001A
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2024-07-09
Abatement Due Date 2024-07-23
Current Penalty 1659.0
Initial Penalty 2765.0
Final Order 2024-09-09
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Main shop; On or about March 20, 2024 and times prior employees were exposed to caught-in hazards in that the employer failed to ensure procedures were developed, documented and utilized for the control of potentially hazardous energy for employees performing maintenance tasks on equipment such as, but not limited to, the Marvel Series 8 Mark III Band Saw.
Citation ID 02001B
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2024-07-09
Abatement Due Date 2024-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-09
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. a) Main shop; On or about March 20, 2024 and times prior employees were exposed to caught-in hazards in that the employer failed to ensure authorized employees received training on the methods and means necessary for energy isolation for maintenance tasks on equipment such as, but not limited to, the Marvel Series 8 Mark III Band Saw.
Citation ID 02002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2024-07-09
Abatement Due Date 2024-07-23
Current Penalty 2766.0
Initial Penalty 4610.0
Final Order 2024-09-09
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Main Shop; On or about March 20, 2024 and times prior employees were exposed to amputation hazards in that the employer failed to ensure one or more methods of machine guarding were provided at the point of operation on the Green Press Brake. b) Main Shop; On or about March 20, 2024 and times prior employees were exposed to caught-in hazards in that the employer failed to ensure on or more methods of machine guarding were provided at the point of operation on the Lockformer Pittsburg Machine.
Citation ID 03001
Citaton Type Other
Standard Cited 19040041 A01 I
Issuance Date 2024-07-09
Current Penalty 553.2
Initial Penalty 922.0
Final Order 2024-09-09
Nr Instances 1
Nr Exposed 21
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.41(a)(1)(i): The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date: a) 9320 Untreiner Ave, Pensacola, FL; On or about March 2, 2024, the employer failed to electronically submit information from their OSHA Form 300A, Summary of Work-Related Injuries and Illnesses or equivalent form, for the calendar year 2023 on or before March 2, 2024. The establishment employed 20 employees during the calendar year 2023 and was classified under NAICS code 332322.
Citation ID 03002
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2024-07-09
Abatement Due Date 2024-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-09
Nr Instances 1
Nr Exposed 20
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2):The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) Main Shop; On or about March 20, 2024 and times prior the employer failed to verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated, the person certifying that the evaluation had been performed, the date(s) of the hazard assessment, and which identified the document as a certification of hazard assessment.
Citation ID 03003
Citaton Type Other
Standard Cited 19100178 L01 I
Issuance Date 2024-07-09
Abatement Due Date 2024-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-09-09
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Main Shop; On or about March 20, 2024 and times prior the employer failed to ensure employees required to operate powered industrial trucks were competent to operate a powered industrial truck safely through the successful completion of the training and evaluation specified in paragraph (l).
341208809 0419700 2016-01-28 8904 ARCADIA RD, PENSACOLA, FL, 32534
Inspection Type Complaint
Scope NoInspection
Safety/Health Health
Close Conference 2016-01-28
Case Closed 2016-02-16

Related Activity

Type Complaint
Activity Nr 1055422
Health Yes

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9837397706 2020-05-01 0491 PPP 9320 UNTREINER AVE, PENSACOLA, FL, 32534
Loan Status Date 2021-07-07
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 408745
Loan Approval Amount (current) 408745
Undisbursed Amount 0
Franchise Name -
Lender Location ID 39232
Servicing Lender Name Hancock Whitney Bank
Servicing Lender Address 2510 14th St One Hancock Plz, GULFPORT, MS, 39501
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address PENSACOLA, ESCAMBIA, FL, 32534-1000
Project Congressional District FL-01
Number of Employees 31
NAICS code 238210
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 39232
Originating Lender Name Hancock Whitney Bank
Originating Lender Address GULFPORT, MS
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 413297.97
Forgiveness Paid Date 2021-06-11

Date of last update: 01 Apr 2025

Sources: Florida Department of State