Search icon

SUNTREE TECHNOLOGIES, INC. - Florida Company Profile

Company Details

Entity Name: SUNTREE TECHNOLOGIES, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

SUNTREE TECHNOLOGIES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 23 Aug 1999 (26 years ago)
Date of dissolution: 22 Sep 2000 (25 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2000 (25 years ago)
Document Number: P99000076065
Address: 720 MULLET ROAD, UNIT H, CAPE CANAVERAL, FL, 32920
Mail Address: 720 MULLET ROAD, UNIT H, CAPE CANAVERAL, FL, 32920
ZIP code: 32920
County: Brevard
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HAPPEL THOMAS H President 5041 SCOTT ROAD, COCOA, FL, 32926
HAPPEL THOMAS H Director 5041 SCOTT ROAD, COCOA, FL, 32926
HAPPEL THOMAS H Agent 720 MULLET ROAD, CAPE CANAVERAL, FL, 32920

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2000-09-22 - -

Documents

Name Date
Domestic Profit 1999-08-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342230778 0420600 2017-04-06 798 CLEARLAKE RD., COCOA, FL, 32922
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-04-06
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2017-07-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2017-05-17
Abatement Due Date 2017-07-05
Current Penalty 5323.8
Initial Penalty 8873.0
Final Order 2017-05-31
Nr Instances 3
Nr Exposed 27
Gravity 10
FTA Current Penalty 0.0
Citation text line Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by fragments of plastic pipe used to transport compressed air for the operation of air operated tools and air used for cleaning, in the event the piping ruptures a. On or about 4/6/2017, in the basket assembly area, final assembly area, metal cutting area, baskets and skimmers assembly area, cutting & grinding area, and the back warehouse storage area and the R & D area, plastic PVC piping was used in exposed above ground locations, a practice prohibited by ANSI/ASME B31.8-1986, Gas Transmission and Distribution Piping System Standard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100303 G01
Issuance Date 2017-05-17
Abatement Due Date 2017-05-30
Current Penalty 2281.2
Initial Penalty 3802.0
Final Order 2017-05-31
Nr Instances 1
Nr Exposed 10
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment. a. In the basket assembly area, four separate electrical panels were obstructed by tools and equipment, exposing employees to electrical shock hazards, on or about 4/6/2017.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2017-05-17
Abatement Due Date 2017-07-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-31
Nr Instances 1
Nr Exposed 27
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. a. In the cutting and grinding area, where workers were required to wear respirators, there was no respiratory protection program, on or about 4/6/2017.
Citation ID 02002
Citaton Type Other
Standard Cited 19100157 G01
Issuance Date 2017-05-17
Abatement Due Date 2017-06-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-31
Nr Instances 1
Nr Exposed 27
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. a. At the facility, employees were required to use fire extinguishers to extinguish incipient stage fires, and the employer did not provide fire extinguisher training to the employees, exposing employees to fire hazards, on or about 4/6/20/16.
Citation ID 02003
Citaton Type Other
Standard Cited 19100303 F02
Issuance Date 2017-05-17
Abatement Due Date 2017-06-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-05-31
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. a. In the basket assembly area, a circuit breaker was not marked to indicate its purpose, exposing employees to minor shock hazards, on or about 4/6/2017.
339562894 0419700 2014-01-28 SE 4TH STREET AND DUPONT AVENUE, GAINESVILLE, FL, 32601
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2014-01-28
Emphasis N: TRENCH
Case Closed 2014-07-30

Related Activity

Type Referral
Activity Nr 868283
Safety Yes
Type Inspection
Activity Nr 954792
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-06-23
Abatement Due Date 2014-06-27
Current Penalty 2520.0
Initial Penalty 4200.0
Final Order 2014-07-08
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about January 10, 2014, employees working inside the baffle box were not wearing hard hats, exposing themselves to being struck-by chunks of rocks, clay, bricks and wood. b. On or about January 13, 2014, employees working inside the baffle box were not wearing hard hats, exposing themselves to being struck-by chunks of clay and rocks.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-06-23
Abatement Due Date 2014-06-27
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2014-07-08
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. On or about January 13, 2014, on top of the baffle box, employees installing the sunglide lid were not protected from a 15-foot fall hazard by use of a fall protection system. b. On or about January 10, 2014, on top of the 54-inch reinforced concrete pipe, two employees were not protected from a 7 feet fall hazard by use of a fall protection system.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B06
Issuance Date 2014-06-23
Abatement Due Date 2014-06-27
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2014-07-08
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(6): Each employee on ramps, runways, and other walkways was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems: a. On or about January 13, 2014, the walkway used to access the baffle box did not have a guardrail, exposing employees to a 15-foot fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-06-23
Current Penalty 2520.0
Initial Penalty 4200.0
Final Order 2014-07-08
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a. On or about January 13, 2014, employees used an 8-foot Little Giant ladder to access/egress the top of the baffle box, exposing themselves to a 15-foot fall hazard.