347863169
|
0419700
|
2024-11-06
|
106 CHARLES HAYES SR. DRIVE, GRETNA, FL, 32332
|
|
Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2024-11-06
|
Related Activity
Type |
Accident |
Activity Nr |
2230483 |
|
|
346554595
|
0420600
|
2023-03-09
|
5251 W TYSON AVE, TAMPA, FL, 33611
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-03-09
|
Emphasis |
N: RCS-NEP
|
Case Closed |
2023-08-03
|
Related Activity
Type |
Complaint |
Activity Nr |
2007532 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2023-06-23 |
Abatement Due Date |
2023-08-10 |
Current Penalty |
5062.8 |
Initial Penalty |
8438.0 |
Final Order |
2023-08-01 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about March 9, 2023 at the yard, the employer did not ensure that employees required to wear tight-fitting respirators were provided a medical evaluation to determine their ability to use respirators in the workplace. Employees involved in grinding operations were provided and required to wear 3M - Half face Respirator. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 F02 |
Issuance Date |
2023-06-23 |
Abatement Due Date |
2023-08-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-01 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator a) On or about March 9, 2023 at the yard, the employer did not ensure that employees required to wear tight-fitting respirator were fit tested prior to initial use of the respirator in the workplace. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2023-06-23 |
Abatement Due Date |
2023-07-20 |
Current Penalty |
3375.0 |
Initial Penalty |
5625.0 |
Final Order |
2023-08-01 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:(a) a) On or about March 9, 2023, at the yard, the Dewalt Angle Grinder was not guarded, exposing employees to amputation hazards. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260350 A01 |
Issuance Date |
2023-06-23 |
Abatement Due Date |
2023-07-20 |
Current Penalty |
5062.8 |
Initial Penalty |
8438.0 |
Final Order |
2023-08-01 |
Nr Instances |
4 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.350(a)(1):Valve protection cap(s) were not in place and secured on compressed gas cylinder(s): a) On or about March 9, 2023, at the worksite, compressed gas cylinder(s) located near the trailer did not have valve protection caps, exposing employees to a struck-by hazard in the event of sudden release and rupture. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260350 A04 |
Issuance Date |
2023-06-23 |
Abatement Due Date |
2023-07-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-01 |
Nr Instances |
1 |
Nr Exposed |
11 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.350(a)(4): Compressed gas cylinder(s) being transported by powered vehicles were not secured in a vertical position: a) On or about March 9, 2023, at the worksite, a compressed gas cylinder was being transported by a bobcat in a horizontal position without being secured, exposing employees to a fire hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261153 I01 |
Issuance Date |
2023-06-23 |
Abatement Due Date |
2023-07-20 |
Current Penalty |
3375.0 |
Initial Penalty |
5625.0 |
Final Order |
2023-08-01 |
Nr Instances |
1 |
Nr Exposed |
11 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(i)(1):The employer did not include respirable crystalline silica in the program established to comply with the hazard communication standard (HCS) (29 CFR 1910.1200): a.) On or about March 9, 2023, at the yard located at 5251 W Tyson Ave, Tampa, FL 33611 , the employer did not include respirable crystalline silica in the hazard communication program, exposing employees to silica related health hazards. |
|
|
346381197
|
0419700
|
2022-12-08
|
106 CHARLES HAYES SR. DRIVE, GRETNA, FL, 32332
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-12-16
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2022-12-27
|
|
345119960
|
0420600
|
2021-01-21
|
W TYSON AVENUE, TAMPA, FL, 33611
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-01-21
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2021-07-02
|
Related Activity
Type |
Referral |
Activity Nr |
1720881 |
Safety |
Yes |
|
|
342872355
|
0419700
|
2018-01-17
|
106 CHARLES HAYES SR. DRIVE, GRETNA, FL, 32332
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-01-18
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2018-04-04
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2018-03-08 |
Abatement Due Date |
2018-04-03 |
Current Penalty |
3292.8 |
Initial Penalty |
5488.0 |
Final Order |
2018-03-28 |
Nr Instances |
1 |
Nr Exposed |
75 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(I): Except as provided elsewhere in this section, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a. On or about January 17, 2018, the employer did not ensure that each employee who walked on the warehouse rear dock area was protected from a 4-foot, 6-inch fall hazard to the concrete lower level below by the use of a guardrail system. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100029 B02 I |
Issuance Date |
2018-03-08 |
Abatement Due Date |
2018-04-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-28 |
Nr Instances |
1 |
Nr Exposed |
75 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guiderail system and the walking-working surface: a. On or about January 17, 2018, the employer did not ensure that the installed guardrail system for the warehouse rear dock area had a mid-rail installed to protect employees from a 4-foot, 6-inch fall hazard to the concrete lower level below. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100157 C04 |
Issuance Date |
2018-03-08 |
Abatement Due Date |
2018-04-03 |
Current Penalty |
3292.8 |
Initial Penalty |
5488.0 |
Final Order |
2018-03-28 |
Nr Instances |
2 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a. On or about January 17, 2018, in the Metal Shop, where welding and cutting operations were conducted, all six (6) portable fire extinguishers had been used during a previous fire and were not in a fully charged or operable condition, thereby exposing employees to entrapment, smoke inhalation and burn hazards in the event of another fire. b. On or about January 17, 2018, in the Warehouse Production area a portable fire extinguisher's pressure gauge indicated that the fire extinguisher was in an UNDERCHARGED condition and was not in a fully charged or operable condition, thereby exposing an employee to entrapment, smoke inhalation and burn hazards in the event of a fire. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100157 E03 |
Issuance Date |
2018-03-08 |
Abatement Due Date |
2018-04-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a. On or about January 17, 2018, in the Warehouse Production area a portable fire extinguisher's pressure gauge indicated that the fire extinguisher had not received an annual maintenance check, thereby exposing an employee to entrapment, smoke inhalation and burn hazards in the event of a fire. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2018-03-08 |
Abatement Due Date |
2018-04-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-28 |
Nr Instances |
1 |
Nr Exposed |
75 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about January 17, 2018, at the warehouse rear dock area, the employer allowed an employee to operate a powered industrial truck (forklift) without conducting an evaluation of the operators performance in over 5-years, 8-months, thereby exposing the operator and other employees working in the area of forklift operations to struck-by and crushing hazards. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100178 L06 |
Issuance Date |
2018-03-08 |
Abatement Due Date |
2018-04-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-03-28 |
Nr Instances |
1 |
Nr Exposed |
75 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: On or about January 17, 2018, at the warehouse rear dock area, the employer allowed an employee to operate a powered industrial truck (forklift) without first providing a certification of the operators training, thereby exposing the operator and other employees working in the area of forklift operations to struck-by and crushing hazards. |
|
|
340568260
|
0419700
|
2015-04-21
|
106 CHARLES HAYES SR. DRIVE, GRETNA, FL, 32332
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-06-04
|
Emphasis |
N: SILICA, L: SILICA
|
Case Closed |
2015-07-29
|
Related Activity
Type |
Complaint |
Activity Nr |
974652 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2015-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a. On or about April 21, 2015, an employee used an elastomeric half-face negative pressure respirator voluntarily when grinding scrap metal throughout the yard and the employer did not establish and implement a written respiratory protection program that addressed the worksite-specific procedures such as but not limited to employee medical evaluations, and training on the maintenance and care of the respirator. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2015-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about April 21, 2015, an employee who voluntarily wore a half-face negative pressure respirator when grinding scrap metal had not been provided with a medical evaluation prior to wearing the respirator. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2015-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-23 |
Nr Instances |
2 |
Nr Exposed |
40 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a. On or about April 21, 2015, an employee who voluntarily used a NIOSH approved half-face respirator when grinding scrap metal had not received respirator training prior to initial use of the respirator. b. On or about April 21, 2015, employees who voluntarily used 3M NIOSH approved dustmask respirators throughout the yard when spraying Aqua Kure White and sanding concrete forms had not received respirator training prior to initial use of the respirators. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2015-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
40 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about April 21, 2015, employees used hazardous chemicals such as, but not limited to Aqua Kure White and Fister 50/50 Low Odor Release while working throughout the yard and the employer did not provide information and training on the health and physical hazards of these chemicals. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19101200 H03 IV |
Issuance Date |
2015-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-23 |
Nr Instances |
1 |
Nr Exposed |
40 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a. On or about April 21, 2015, employees used hazardous chemicals such as, but not limited to paints, solvents, gasoline, cleaning agents, and lubricants while working at the shooting range and the employer did not provide an explanation of the new labeling system and safety data sheet. |
|
|
338930134
|
0419700
|
2013-02-25
|
106 CHARLES HAYES SR. DRIVE, GRETNA, FL, 32332
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-02-27
|
Emphasis |
L: EISAOF, P: SSTARG12, N: SSTARG12, L: EISAX
|
Case Closed |
2013-08-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2013-03-26 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2013-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a. On or about February 25, 2013, employees were walking on a bridge form while stringing bridge beams, exposing themselves to a 5 feet 5-inch fall hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100146 C04 |
Issuance Date |
2013-03-26 |
Abatement Due Date |
2013-05-10 |
Current Penalty |
1785.0 |
Initial Penalty |
2975.0 |
Final Order |
2013-04-11 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a. On or about February 25, 2013, at the batch plant, employees were working inside a concrete mixer without a permit confine space program, exposing themselves to caught-by hazards. b. On or about February 25, 2013, at the CDS facility, employees were entering the concrete truck mixers without a permit confine space program, exposing themselves to caught-by hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100179 D04 III |
Issuance Date |
2013-03-26 |
Abatement Due Date |
2013-05-10 |
Current Penalty |
1260.0 |
Initial Penalty |
2100.0 |
Final Order |
2013-04-11 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(d)(4)(iii): Fixed ladder(s) on crane(s) were not constructed in compliance with 29 CFR 1910.27: a. On or about February 25, 2013, employees operating the 60-ton gantry crane were using defective ladders that were permanently affixed to the crane, exposing themselves to a fall hazard. b. On or about February 25, 2013, employees operating the 40-ton gantry crane were using defective ladders that were permanently affixed to the crane, exposing themselves to a fall hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-03-26 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2013-04-11 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about February 25, 2013, on the east side of the building, the bender portion on the ironworker did not have the point of operation guard, exposing employees to an amputation hazard. b. On or about February 25, 2013, on the east side of the building the shear portion on the ironworker did not have the point of operation guard, exposing employees to an amputation hazard. c. On or about February 25, 2013, on the east side of the building, the punch portion on the ironworker did not have the point of operation guard, exposing employees to an amputation hazard. d. On or about February 25, 2013, in the steel shop, the Slugger magnet drill press was missing the bit guard, exposing employees to flying debris. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100213 H01 |
Issuance Date |
2013-03-26 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2013-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material: a. On or about February 25, 2013, on the west wall in the storage area, the miter saw did not have the lower blade guard, exposing employees to an amputation hazard. |
|
|