341365278
|
0418800
|
2016-03-31
|
127NW 16TH ST., POMPANO BEACH, FL, 33060
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-03-31
|
Case Closed |
2016-11-14
|
Related Activity
Type |
Complaint |
Activity Nr |
1076734 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1136603 |
Safety |
Yes |
|
Violation Items
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2016-06-07 |
Abatement Due Date |
2016-07-11 |
Current Penalty |
490.0 |
Initial Penalty |
700.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about March 31, 2016, at the above address jobsite, the employer did not provide the information contained in the appendix D to employees using a half-face air purifying respirator during welding operations. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2016-06-07 |
Abatement Due Date |
2016-07-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about March 31, 2016 at the above address jobsite, the employer did not provide a medical evaluation to employees using a half-face air purifying respirators during welding operations. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-06-07 |
Abatement Due Date |
2016-07-01 |
Current Penalty |
490.0 |
Initial Penalty |
700.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about March 31, 2016, at the above address jobsite, the employer did not develop a written hazard communication program for employees exposed to chemicals such as, but not limited to oxygen and acetylene gas. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19101200 F06 II |
Issuance Date |
2016-06-07 |
Abatement Due Date |
2016-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: On or about March 31, 2016, at the above address jobsite, the employer allowed gasoline to be stored in an improper container that was not labeled or marked with the product identity and appropriate information as required by the standard. |
|
Citation ID |
02002C |
Citaton Type |
Other |
Standard Cited |
19101200 H |
Issuance Date |
2016-06-07 |
Abatement Due Date |
2016-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and (2) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced in: On or about March 31, 2016, at the above address jobsite, the employer did not provide training on the chemical hazards present at the workplace. |
|
|
341366037
|
0418800
|
2016-03-31
|
127NW 16TH ST., POMPANO BEACH, FL, 33060
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-31
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2019-02-11
|
Related Activity
Type |
Complaint |
Activity Nr |
1076734 |
Safety |
Yes |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1136527 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-06-29 |
Abatement Due Date |
2016-07-19 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2016-07-29 |
Nr Instances |
5 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Instances: a. On or about March 31st, 2016, at the above addressed jobsite, in the welding area, an employee was exposed to amputation hazards while working with a cold saw blade that had not been provided with a guard. b. On or about March 31st, 2016, at the above addressed jobsite, in the welding area, an employee was exposed to amputation hazards while working with a cold saw blade that had not been provided with a guard. c. On or about March 31st, 2016, at the above addressed jobsite, in the welding area, an employee was exposed to amputation hazards while working with a drill press bit and serrated chuck that had not been provided with a guard. d. On or about March 31st, 2016, at the above addressed jobsite, in the fabrication area, an employee was exposed to amputation hazards while working with a sheer/punch that had not been provided with a guard. e. On or about March 31st, 2016, at the above addressed jobsite, in the canvas shop area, an employee was exposed to amputation hazards while working with a grommet machine that had not been provided with a guard at the point of operation. f. On or about March 31st, 2016, at the above addressed jobsite, in the canvas shop area, an employee was exposed to amputation hazards while working with a grommet machine that had not been provided with a guard around a belt and pulley system. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2016-06-29 |
Current Penalty |
1260.0 |
Initial Penalty |
2100.0 |
Final Order |
2016-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: a. On or about March 31st, 2016, at the above address jobsite, employees were exposed to a fire hazard while working near oxygen and acetylene cylinders that were stored together. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100253 B05 III I |
Issuance Date |
2016-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(5)(iii)(I): Fuel-gas was used from cylinders through torches or other devices equipped with shutoff valves without reducing the pressure through a suitable regulator attached to the cylinder valve or manifold: a. On or about March 31st, 2016, at the above address jobsite, employees were exposed to a fire hazard while using damaged regulators on the acetylene cylinders. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2016-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about March 31st, 2016, at the above address jobsite, employees were exposed to a potential electrical shock while operating a saw that was energized using an extension cord as a substitute for a fixed outlet. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100305 B02 I |
Issuance Date |
2016-06-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-29 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. On or about March 31st, 2016, at the above address jobsite, employees were exposed to a potential electrical shock while working in vicinity of open electrical outlet boxes. |
|
|
340669019
|
0418800
|
2015-06-01
|
3001 N. FEDERAL HWY, FORT LAUDERDALE, FL, 33306
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-01
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-09-18
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2015-07-17 |
Abatement Due Date |
2015-07-23 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-08-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 1 June, 2015, at the above addressed jobsite, two employees were working from the top of a commercial building under renovation without the use of fall protection, exposing the employee to a fall hazard of up to approximately 9 feet. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2015-07-17 |
Abatement Due Date |
2015-07-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-08-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about 1 June, 2015, at the above addressed jobsite, two employees were working on top of a commercial building under renovation without the employer providing fall protection training, exposing the employees to a fall hazard of up to approximately 9 feet. |
|
|