Search icon

MCKENDRY BUILDERS INC. - Florida Company Profile

Company Details

Entity Name: MCKENDRY BUILDERS INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

MCKENDRY BUILDERS INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 28 Jan 1999 (26 years ago)
Document Number: P99000010082
FEI/EIN Number 650890193

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 80 Palm Dr, Key West, FL, 33040, US
Mail Address: 80 Palm Dr, Key West, FL, 33040, US
ZIP code: 33040
County: Monroe
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MCKENDRY BRIAN T Director 80 Palm Dr, Key West, FL, 33040
MCKENDRY BRIAN T President 80 Palm Dr, Key West, FL, 33040
MCKENDRY BRIAN T Secretary 80 Palm Dr, Key West, FL, 33040
MCKENDRY BRIAN T Treasurer 80 Palm Dr, Key West, FL, 33040
FARRELLY GREGORY G Agent 506 Louisa St, Key West, FL, 33040

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2023-02-16 80 Palm Dr, Key West, FL 33040 -
CHANGE OF MAILING ADDRESS 2019-03-14 80 Palm Dr, Key West, FL 33040 -
REGISTERED AGENT ADDRESS CHANGED 2019-03-14 506 Louisa St, Key West, FL 33040 -
REGISTERED AGENT NAME CHANGED 2002-01-21 FARRELLY, GREGORY G -

Documents

Name Date
ANNUAL REPORT 2024-02-26
ANNUAL REPORT 2023-02-16
ANNUAL REPORT 2022-02-26
ANNUAL REPORT 2021-02-22
ANNUAL REPORT 2020-02-01
ANNUAL REPORT 2019-03-14
ANNUAL REPORT 2018-01-19
ANNUAL REPORT 2017-01-20
ANNUAL REPORT 2016-02-19
ANNUAL REPORT 2015-02-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341304624 0418800 2016-03-02 920 EISENHOWER DR, KEY WEST, FL, 33040
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-03-03
Emphasis L: FALL
Case Closed 2016-06-06

Related Activity

Type Complaint
Activity Nr 1067807
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260304 H01
Issuance Date 2016-03-16
Abatement Due Date 2016-03-22
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-04-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood meeting all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws: On or about March 2, 2016, at the above addressed worksite, an employee was exposed to a caught by hazard while working with a table saw that lacked a guard.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260304 I01
Issuance Date 2016-03-16
Abatement Due Date 2016-03-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: On or about March 2, 2016, at the above addressed worksite, an employee was exposed to a caught by hazard a while working with a table saw that lacked a guard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2016-03-16
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2016-04-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: On or about March 2, 2016, at the above addressed worksite, an employee was exposed to a fall hazard while using a stairway that lacked a stair railing system.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-03-16
Abatement Due Date 2016-03-22
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2016-04-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about September 22, 2015, at the above addressed worksite, an employee was exposed to the hazard of falling 8'-8" to a lower level while working on an attic.
Citation ID 02001
Citaton Type Other
Standard Cited 19260403 B01 I
Issuance Date 2016-03-16
Abatement Due Date 2016-03-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-07
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. On or about March 2, 2016, at the above addressed worksite, a metal outlet box part of a shop-made extension cord was not used as listed or labeled, exposing an employee to an electrical hazard.
Citation ID 02002
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2016-03-16
Abatement Due Date 2016-03-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-04-07
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or about March 2, 2016, at the above addressed worksite, a shop-made extension cord lacked strain, exposing an employee to an electrical hazard.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9700178607 2021-03-26 0455 PPS 80 Palm Dr, Key West, FL, 33040-6130
Loan Status Date 2021-11-17
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 387800
Loan Approval Amount (current) 387800
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17215
Servicing Lender Name First State Bank of the Florida Keys
Servicing Lender Address 1201 Simonton St, KEY WEST, FL, 33040-3111
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Key West, MONROE, FL, 33040-6130
Project Congressional District FL-28
Number of Employees 15
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 17215
Originating Lender Name First State Bank of the Florida Keys
Originating Lender Address KEY WEST, FL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 389997.53
Forgiveness Paid Date 2021-10-27
2209297305 2020-04-29 0455 PPP 80 PALM DR, KEY WEST, FL, 33040-6130
Loan Status Date 2021-06-17
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 387800
Loan Approval Amount (current) 387800
Undisbursed Amount 0
Franchise Name -
Lender Location ID 17215
Servicing Lender Name First State Bank of the Florida Keys
Servicing Lender Address 1201 Simonton St, KEY WEST, FL, 33040-3111
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address KEY WEST, MONROE, FL, 33040-6130
Project Congressional District FL-28
Number of Employees 15
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 17215
Originating Lender Name First State Bank of the Florida Keys
Originating Lender Address KEY WEST, FL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 391882.67
Forgiveness Paid Date 2021-05-21

Date of last update: 01 May 2025

Sources: Florida Department of State