Search icon

RODRIGUEZ CONSTRUCTION, INC. - Florida Company Profile

Company Details

Entity Name: RODRIGUEZ CONSTRUCTION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

RODRIGUEZ CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 30 Nov 1998 (26 years ago)
Date of dissolution: 24 Sep 1999 (26 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 24 Sep 1999 (26 years ago)
Document Number: P98000099550
Address: 915 W 74TH STREET, APT. 118, HIALEAH, FL, 33014
Mail Address: 915 W 74TH STREET, APT. 118, HIALEAH, FL, 33014
ZIP code: 33014
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
FIGUEROA ALBERTO President 7225 WEST 11TH CT., APT. 315, HIALEAH, FL, 33014
FIGUEROA ALBERTO Director 7225 WEST 11TH CT., APT. 315, HIALEAH, FL, 33014
FIGUEROA ALBERTO Agent 7225 WEST 11TH CT., NO. 315, HIALEAH, FL, 33014

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 1999-09-24 - -
AMENDMENT 1999-08-23 - -
REGISTERED AGENT NAME CHANGED 1999-08-23 FIGUEROA, ALBERTO -
REGISTERED AGENT ADDRESS CHANGED 1999-08-23 7225 WEST 11TH CT., NO. 315, HIALEAH, FL 33014 -

Documents

Name Date
Amendment 1999-08-23
Domestic Profit 1998-11-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339609810 0419700 2014-03-04 1903 ASHMORE GREEN DRIVE, JACKSONVILLE, FL, 32224
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-03-04
Emphasis P: FALL, L: EISAOF, L: FALL
Case Closed 2018-09-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-03-10
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-04-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about March 4, 2014, employees working below roofing operations were not wearing hard hats, exposing themselves to being hit by flying objects or falling debris.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-03-10
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-04-01
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about March 4, 2014, an employee using a Hitachi pneumatic air nail gun was not wearing safety glasses, exposing himself to being hit by nails or flying deris. b. On or about March 4, 2014, an employee using a compact circular handsaw was not wearing safety glasses, exposing himself to being hit by flying debris.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260300 B02
Issuance Date 2014-03-10
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-04-01
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(2): Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating, or moving parts of equipment exposed to contact by the employees or which otherwise created a hazard, were not guarded: a. On or about March 4, 2014, a Rolair air compressor was not guarded, exposing employees to struck-by or caught-in hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-03-10
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2014-04-01
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about March 4, 2014, on a 5:12 pitch roof, five employees performing rooing operations were not protected from an 8-foot 8-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection. b. On or about March 4, 2014, on a 5:12 pitch roof, employees performing roofing operations were not protected from stepping or falling into a hole in the roof, which was an 8-foot interior fall hazard by use of a personal fall arrest system, covers or guardrails erected around the hole.

Date of last update: 01 Apr 2025