Search icon

HI-TECH PLASTERING, CORP. - Florida Company Profile

Company Details

Entity Name: HI-TECH PLASTERING, CORP.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HI-TECH PLASTERING, CORP. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 23 Oct 1998 (27 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 16 Oct 2023 (2 years ago)
Document Number: P98000090381
FEI/EIN Number 650871727

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 16830 SW 62nd ST, Southwest Ranches, FL, 33331, US
Mail Address: 16830 SW 62nd ST, Southwest Ranches, FL, 33331, US
ZIP code: 33331
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MORALES RUBEN President 6991 WEST BROWARD BLVD, PLANTATION, FL, 33317
MORALES RUBEN Agent 16830 SW 62nd ST, Southwest Ranches, FL, 33331

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2023-10-16 MORALES, RUBEN -
REINSTATEMENT 2023-10-16 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -
REINSTATEMENT 2020-10-06 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2020-09-25 - -
REGISTERED AGENT ADDRESS CHANGED 2016-04-30 16830 SW 62nd ST, Southwest Ranches, FL 33331 -
CHANGE OF PRINCIPAL ADDRESS 2016-04-30 16830 SW 62nd ST, Southwest Ranches, FL 33331 -
CHANGE OF MAILING ADDRESS 2016-04-30 16830 SW 62nd ST, Southwest Ranches, FL 33331 -
REINSTATEMENT 2013-12-20 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J11000210323 TERMINATED 1000000210042 BROWARD 2011-03-31 2021-04-06 $ 582.50 STATE OF FLORIDA, DEPARTMENT OF REVENUE, CORAL SPRINGS SERVICE CENTER, 3111 N UNIVERSITY DR STE 501, CORAL SPRINGS FL330655096

Documents

Name Date
ANNUAL REPORT 2024-04-02
REINSTATEMENT 2023-10-16
ANNUAL REPORT 2022-06-22
ANNUAL REPORT 2021-04-30
REINSTATEMENT 2020-10-06
ANNUAL REPORT 2019-04-29
ANNUAL REPORT 2018-03-28
ANNUAL REPORT 2017-01-04
ANNUAL REPORT 2016-04-30
ANNUAL REPORT 2015-04-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347262958 0418800 2024-02-06 5286 NEVOLA AVENUE, AVE MARIA, FL, 34142
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2024-02-06
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-07-01
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about 02/06/2024, at Lot 5286 Nevola Avenue, in Ave Maria, Florida, employees of a subcontractor applying stucco on a 2-story townhome were exposed to 16-foot fall hazards from a scaffold due to lack of planking.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2024-07-01
Abatement Due Date 2024-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-07-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. On or about 02/06/2024, at Lot 5286 Nevola Avenue, in Ave Maria, Florida, the employer did not ensure that there was a competent person in scaffold erection during the task of applying stucco on a 2-story townhome, which exposed employees of a subcontractor to 16-foot fall hazards due to the several deficiencies with the scaffold the employees were using.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2024-07-01
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: On or about 02/06/2024, at Lot 5286 Nevola Avenue, in Ave Maria, Florida, employees of a subcontractor applying stucco on a 2-story townhome were exposed to 16-foot fall hazards due to a scaffold being erected on top of cement block units making the scaffold unstable.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-07-01
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. On or about 02/06/2024, at Lot 5286 Nevola Avenue, in Ave Maria, Florida, employees of a subcontractor applying stucco on a 2-story townhome were exposed to 16-foot fall hazards on the scaffold due to lack of safe access to and from the scaffold.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2024-07-01
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about 02/06/2024, at Lot 5286 Nevola Avenue, in Ave Maria, Florida, employees of a subcontractor applying stucco on a 2-story townhome were exposed to 16-foot fall hazards on the scaffold due to lack of guardrails.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2024-07-01
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-07-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 02/06/2024, at Lot 5286 Nevola Avenue, in Ave Maria, Florida, employees of a subcontractor applying stucco on a 2-story townhome were exposed to 16-foot fall hazards on the scaffold due to lack of crossbracing on several sections of the scaffold.
346056328 0418800 2022-06-29 16830 SW 62ND ST, SOUTHWEST RANCHES, FL 33331, SOUTHWEST RANCHES, FL, 33331
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2022-06-29
Emphasis L: FALL
Case Closed 2022-12-29
334395738 0418800 2012-05-14 8422 NW 40TH ST, COOPER CITY, FL, 33328
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-05-14
Emphasis L: FALL
Case Closed 2012-07-27

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2012-05-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-06-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): The employer did not ensure each platform on all working levels of scaffolds were fully planked or decked between the front uprights and the guardrail supports as follows: On or about 05-14-12 at 8422 NW 40th St Cooper City, FL. 33024, an employee was exposed to a fall hazard of approximately 16 feet to ground level from a scaffold that was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2012-05-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-06-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about 05-14-12 at 8422 NW 40th St Cooper City, FL. 33024, an employee was exposed to a fall hazard of approximately 16 feet to ground level while working from a scaffold that was lacking guardrails.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2012-05-25
Abatement Due Date 2012-06-04
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2012-06-25
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. On or about 05-14-12 at 8422 NW 40th St Cooper City, FL. 33024, an employee working on a scaffold 16 feet above ground level, was trained on the recognition of fall hazards. PLEASE NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION
316328681 0418800 2012-05-14 8291 NW 38TH ST., COOPER CITY, FL, 33024
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2012-05-14
Case Closed 2012-05-30

Related Activity

Type Inspection
Activity Nr 315351031
315351031 0418800 2011-02-22 8291 NW 38TH ST., COOPER CITY, FL, 33024
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2011-02-23
Emphasis L: FALL
Case Closed 2012-05-31

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B01
Issuance Date 2011-08-10
Abatement Due Date 2011-08-29
Current Penalty 1980.0
Initial Penalty 1980.0
Nr Instances 1
Nr Exposed 5
Gravity 01
312147267 0418800 2008-06-20 2300 E. SUNRISE BLVD., FORT LAUDERDALE, FL, 33304
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2008-06-20
Emphasis L: FALL
Case Closed 2008-07-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2008-06-25
Abatement Due Date 2008-06-30
Current Penalty 450.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2008-06-25
Abatement Due Date 2008-06-30
Current Penalty 1125.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 2
Gravity 10
307301739 0418800 2004-08-18 8291 NW 38TH ST., COOPER CITY, FL, 33024
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2004-08-18
Emphasis L: FALL
Case Closed 2004-10-01

Related Activity

Type Referral
Activity Nr 200683936
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2004-09-07
Abatement Due Date 2004-09-10
Current Penalty 600.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 02

Date of last update: 01 Apr 2025