Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2020-10-30
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2021-11-12
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100107 C07 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-03-11 |
Current Penalty |
1492.2 |
Initial Penalty |
2487.0 |
Final Order |
2021-06-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(c)(7):Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not protected from mechanical injury by suitable guards or by location: a. On October 30, 2020, in the shop, the fluorescent light above the area used to spray contact cement was within 14 feet, exposing employees to a fire hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
1790.4 |
Initial Penalty |
2984.0 |
Final Order |
2021-06-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1):Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a. On October 30, 2020, in the shop, employees using saws to cut laminate and wood were not wearing safety glasses, exposing themselves to the hazard of getting wood dust in the eye. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
1790.4 |
Initial Penalty |
2984.0 |
Final Order |
2021-06-15 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1):Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a. On October 30, 2020, in the shop, the Delta table saw used to cut laminate did not have a hood guard, exposing employees to the hazard of being cut by the 10- inch blade. b. On October 30, 2020, in the shop, the Craftsman table saw used to cut wood did not have a hood guard, exposing employees to the hazard of being cut by the 8- inch blade. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100213 H01 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
1194.0 |
Initial Penalty |
1990.0 |
Final Order |
2021-06-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(1):The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock: a. On October 30, 2020, in the shop, the Craftsman radial arm saw did not have an adjustable guard on the lower half of the blade, exposing employees to the hazard of being cut by the 10- inch blade. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100213 H04 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-06-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(4):Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: a. On October 30, 2020, in the shop, the Craftsman radial arm saw did not return to the starting position when released by the operator. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 B01 II |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-06-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a. On October 30, 2020, in the shop, the employer had created and allowed employees to use, four (4) job-made extension cords that hung freely from the overhead and were constructed with receptacle boxing that was intended for use as a permanent installation, exposing employees to electrical shock hazards. |
|
|