Search icon

ROLLS RITE TRAILERS, INC. - Florida Company Profile

Company Details

Entity Name: ROLLS RITE TRAILERS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ROLLS RITE TRAILERS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 12 Jun 1998 (27 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 11 Jan 2012 (13 years ago)
Document Number: P98000052959
FEI/EIN Number 593519418

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446, US
Mail Address: 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446
ZIP code: 32446
County: Jackson
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
DUNLAP JOYCE C Director 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446
Reynolds William EIII Chief Operating Officer 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446
DUNLAP JOYCE C Agent 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2013-04-16 DUNLAP, JOYCE C -
CHANGE OF PRINCIPAL ADDRESS 2013-04-16 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL 32446 -
REGISTERED AGENT ADDRESS CHANGED 2013-04-16 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL 32446 -
REINSTATEMENT 2012-01-11 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2011-09-23 - -
AMENDMENT 2008-11-07 - -
AMENDMENT 2007-04-06 - -
REINSTATEMENT 2000-03-09 - -
CHANGE OF MAILING ADDRESS 2000-03-09 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL 32446 -
ADMIN DISSOLUTION FOR ANNUAL REPORT 1999-09-24 - -

Documents

Name Date
ANNUAL REPORT 2025-01-07
AMENDED ANNUAL REPORT 2024-08-27
ANNUAL REPORT 2024-01-16
ANNUAL REPORT 2023-01-18
ANNUAL REPORT 2022-01-26
ANNUAL REPORT 2021-02-01
ANNUAL REPORT 2020-01-21
ANNUAL REPORT 2019-02-07
ANNUAL REPORT 2018-01-16
ANNUAL REPORT 2017-01-11

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PURCHASE ORDER AWARD N6883608P3600 2008-09-24 2008-10-23 2008-10-23
Unique Award Key CONT_AWD_N6883608P3600_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 10390.00
Current Award Amount 10390.00
Potential Award Amount 10390.00

Description

Title FORKLIFT TRAILER
NAICS Code 336212: TRUCK TRAILER MANUFACTURING
Product and Service Codes 2330: TRAILERS

Recipient Details

Recipient ROLLS RITE TRAILERS, INC
UEI F2LAZ1BKLJA8
Recipient Address 3741 INDUSTRIAL PARK DR, MARIANNA, JACKSON, FLORIDA, 324468096, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346455868 0418600 2023-01-24 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 2023-02-28
Emphasis L: FORKLIFT
Case Closed 2023-08-17

Related Activity

Type Complaint
Activity Nr 1989221
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100106 E02 IV A
Issuance Date 2023-04-13
Abatement Due Date 2023-04-21
Current Penalty 2500.0
Initial Penalty 3572.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(2)(iv)(a):Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), were not kept in covered containers when not actually in use: a)Spray finishing paint booth: On or about January 24, 2023, and at times prior to, employee(s) were exposed to injuries including burns from fire in that the employer did not ensure three, five- gallon flammable liquids containers with a flashpoint below 100 degrees Fahrenheit were covered while not in use.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100107 B05 IV
Issuance Date 2023-04-13
Abatement Due Date 2023-06-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(iv):Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) Spray Paint Booth and Filter System: On or about January 24, 2023, and at times prior to, the employer exposed employees to fire and explosion hazards by not protecting space within the spray booth with sprinklers on the downstream and upstream side of the filters while performing spray finishing operations using flammable liquid paints.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2023-04-13
Current Penalty 1875.0
Initial Penalty 2678.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) Facility wide: On or about January 24, 2023, and at times prior to, the employer exposed employees to chemical and fire hazards in that employees were exposed to chemical such as but not limited to the following: Flammable paints, chemicals in paints, welding fumes and metal dusts from grinding. Employees were exposed while conducting spray finishing, welding and grinding job tasks and the employer did not ensure a written hazard communication program was implemented at the workplace.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19101200 E01 I
Issuance Date 2023-04-13
Abatement Due Date 2023-04-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1)(i):The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. a) Facility wide: On or about January 24, 2023, and at times prior to, the employer exposed employees to chemical and fire hazards in that employees were exposed to chemical such as but not limited to the following: Flammable paints, chemicals in paints, welding fumes and metal dusts from grinding. Employees were exposed while conducting spray finishing, welding and grinding job tasks and the employer did not ensure a chemical inventory list was on site or available to employees at the workplace.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2023-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Facility wide: On or about January 24, 2023, and at times prior to, the employer exposed employees to chemical hazards in that employees were exposed to chemical such as but not limited to the following: flammable paints, welding fumes and metal dust. Employees were exposed while conducting welding, metal sanding and spray finishing operation job tasks and the employer did not ensure a training was conducted on hazard communication program.
Citation ID 02001
Citaton Type Other
Standard Cited 19040032 A02
Issuance Date 2023-04-13
Current Penalty 625.0
Initial Penalty 893.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.32(a)(2):29 CFR 1904.32(a)(2): At the end of each calendar year, an annual summary was not created for injuries and illnesses recorded on the OSHA 300 Log: a) Rolls Rite Trailers, Inc.: On or about April 21, 2022, the employer failed to create and certify an OSHA form 300A, Summary of Work-Related Injuries and Illnesses or equivalent form, for calendar year 2022 . The establishment had a recordable accident of an employee on July 27, 2022, with 39 days away from work.
Citation ID 02002
Citaton Type Other
Standard Cited 19100094 C07 III B
Issuance Date 2023-04-13
Abatement Due Date 2023-04-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.94(c)(7)(iii)(b):A pressure gage marked to show the pressure drop across the filters of the spray booth to indicate that the filters require cleaning or replacement was not installed: a) Spray Finishing Paint Booth: On or about January 24, 2023, and at times prior, the employer failed to install a gauge that will show pressure drop across filters to ensure filters are replaced or cleaned to ensure airflow through the booth when employees are conducting painting activities.
Citation ID 02003
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 2023-04-13
Abatement Due Date 2023-04-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i):The average air speed over the open face of the paint spray booth or cross section was less than 100 linear feet per minute. a) Spray Finishing Operations Paint Booth: On or about January 24, 2023, and at times prior to, the employer failed to ensure the average air velocity at the cross section of the paint booth was not less than 100 ft/min while an employee conducted spray finishing painting operations.
Citation ID 02004
Citaton Type Other
Standard Cited 19100134 K06
Issuance Date 2023-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Shop areas: On or about January 24, 2023, and at times prior to, the employer failed to provide training on Appendix D of the respiratory protection standard to employees who voluntarily use N95 particulate respirators when grinding and sanding.
Citation ID 02005
Citaton Type Other
Standard Cited 19100219 D01
Issuance Date 2023-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Outside spray finishing booth: On or about January 24, 2024, and at times prior, the employer failed to ensure the belt and pulley of the spray finishing operation exhaust fan motor was guarded.
340034727 0419700 2014-10-21 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2014-10-21
Case Closed 2015-02-17

Related Activity

Type Inspection
Activity Nr 956404
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100134 D01 II
Issuance Date 2015-01-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-02-06
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: a. On or about October 21, 2014, an employee that was required to wear a respirator when spray painting trailers was not provided a NIOSH-certified respirator.
339564049 0419700 2014-01-28 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL, 32446
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2014-02-11
Emphasis L: FORKLIFT, N: AMPUTATE, P: LEAD, N: LEAD
Case Closed 2015-04-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100107 C06
Issuance Date 2014-04-11
Abatement Due Date 2014-05-07
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2014-05-05
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a. On or about January 28, 2014, a wall mounted electrical receptacle box in the spray room used to the power the airless spray painting pump was within 10 feet of the spraying area, exposing the employee to fire hazards. b. On or about January 28, 2014, the fluorescent lights in the spray room were within 13 feet 10 inches of the spraying area, exposing the employee to fire hazards.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 C01 III
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 1100.0
Initial Penalty 2800.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1)(iii): The written program did not contain fit test procedures for tight-fitting respirators: a. On or about February 11, 2014, the spray painter wore a half-face respirator and the employer's written respiratory protection program did not address fit testing procedures.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or used the respirator in the workplace: a. On or about February 11, 2014, an employee who wore a half-face respirator had not been provided with a medical evaluation prior to wearing the respirator.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. On or about February 11, 2014, an employee who wore a half-face respirator had not been fit tested prior to initial use of the respirator.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to employees using a respirator in the workplace: a. On or about February 11, 2014, an employee who wore a half-face respirator had not received respirator training.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19101000 A02
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Carbon Black listed in Table Z-1 in excess of the 8 hour Time Weighted Average (TWA) concentration of 3.5 milligrams per cubic meter (mg/m3): a. An employee spray painting metal trailers was exposed to Carbon Black at a TWA of 5.4 mg/m3, 1.6 times the permissble exposure limit of 3.5 mg/m3. The sampling was performed during one shift on February 11, 2014, for 165 minutes.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100157 C04
Issuance Date 2014-04-11
Current Penalty 1000.0
Initial Penalty 1200.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 16
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a. On or about January 28, 2014, the employer did not ensure that fire extinguishers provided for employees use in the event of a fire were fully charged and in operable condition because all of the fire extinguishers throughout the facility had not been inspected since September 2009, exposing employees to fire hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100252 B02 III
Issuance Date 2014-04-11
Current Penalty 1100.0
Initial Penalty 2000.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 16
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a. On or about January 28, 2014, employees working next to welding areas were not protected from welding rays.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100253 B04 III
Issuance Date 2014-04-11
Current Penalty 1100.0
Initial Penalty 2000.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 16
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. On or about January 28, 2014, bottle storage area, oxygen and acetylene cylinders were stored within 9 feet of each other and were not separated by a noncombustible barrier.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 1100.0
Initial Penalty 2800.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 16
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about January 28, 2014, the employer did not develop and implement the written hazard communication program which described how requirements of 29 CFR 1910.1200(f), (g), and (h) would be met for employees who have exposure to hazardous materials such as but not limited to ethyl benzene, xylene, carbon black, oxygen, and acetylene.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 16
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about January 28, 2014, the employer did not provide information and training to employees who had exposure to hazardous materials such as but not limited to ethyl benzene, xylene, carbon black, oxygen, and acetylene.
Citation ID 01006C
Citaton Type Serious
Standard Cited 19101200 H03 IV
Issuance Date 2014-04-11
Abatement Due Date 2014-06-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 16
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a. On or about January 28, 2014, the employer did not include in the hazard communication program an explanation of the labeling system, safety data sheet, and training to employees who have exposure to hazardous materials such as but not limited to ethyl benzene, xylene, carbon black, oxygen, and acetylene.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 L01 I
Issuance Date 2014-04-11
Abatement Due Date 2014-05-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-05
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On or about January 28, 2014, employees that operated powered industrial trucks throughout the workplace were not provided the required training and evaluation.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4927168301 2021-01-23 0491 PPS 3741 Industrial Park Dr, Marianna, FL, 32446-8096
Loan Status Date 2021-09-14
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 155000
Loan Approval Amount (current) 155000
Undisbursed Amount 0
Franchise Name -
Lender Location ID 88793
Servicing Lender Name First Federal Bank
Servicing Lender Address 4705 W US Hwy 90, LAKE CITY, FL, 32055-4884
Rural or Urban Indicator R
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address Marianna, JACKSON, FL, 32446-8096
Project Congressional District FL-02
Number of Employees 26
NAICS code 336212
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Subchapter S Corporation
Originating Lender ID 88793
Originating Lender Name First Federal Bank
Originating Lender Address LAKE CITY, FL
Gender Male Owned
Veteran Unanswered
Forgiveness Amount 155908.47
Forgiveness Paid Date 2021-08-31
5823167000 2020-04-06 0491 PPP 3741 INDUSTRIAL PARK DR, MARIANNA, FL, 32446-8096
Loan Status Date 2020-12-08
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 150000
Loan Approval Amount (current) 150000
Undisbursed Amount 0
Franchise Name -
Lender Location ID 88793
Servicing Lender Name First Federal Bank
Servicing Lender Address 4705 W US Hwy 90, LAKE CITY, FL, 32055-4884
Rural or Urban Indicator R
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address MARIANNA, JACKSON, FL, 32446-8096
Project Congressional District FL-02
Number of Employees 27
NAICS code 336212
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Subchapter S Corporation
Originating Lender ID 88793
Originating Lender Name First Federal Bank
Originating Lender Address LAKE CITY, FL
Gender Male Owned
Veteran Unanswered
Forgiveness Amount 150891.67
Forgiveness Paid Date 2020-11-23

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P3255967 ROLLS RITE TRAILERS, INC - F2LAZ1BKLJA8 3741 INDUSTRIAL PARK DR, MARIANNA, FL, 32446-8096
Capabilities Statement Link -
Phone Number 850-526-2290
Fax Number 850-526-2299
E-mail Address sales@rollsrite.com
WWW Page -
E-Commerce Website -
Contact Person BRIAN WILKERSON
County Code (3 digit) 063
Congressional District 02
Metropolitan Statistical Area -
CAGE Code 1UNT6
Year Established 1998
Accepts Government Credit Card Yes
Legal Structure Corporation
Ownership and Self-Certifications -
Business Development Servicing Office NORTH FLORIDA DISTRICT OFFICE (SBA office code 0491)
Capabilities Narrative (none given)
Special Equipment/Materials (none given)
Business Type Percentages (none given)
Keywords (none given)
Quality Assurance Standards (none given)
Electronic Data Interchange capable -

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level (none given)
Description Construction Bonding Level (aggregate)
Level (none given)
Description Service Bonding Level (per contract)
Level (none given)
Description Service Bonding Level (aggregate)
Level (none given)

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 336212
NAICS Code's Description Truck Trailer Manufacturing
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Firm hasn't answered this question yet
Export Business Activities (none given)
Exporting to (none given)
Desired Export Business Relationships (none given)
Description of Export Objective(s) (none given)

Date of last update: 03 Apr 2025

Sources: Florida Department of State