341101566
|
0419700
|
2015-12-07
|
7768 OZARK DR, JACKSONVILLE, FL, 32256
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-12-07
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2015-12-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2015-12-14 |
Current Penalty |
816.0 |
Initial Penalty |
1360.0 |
Final Order |
2015-12-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On December 7, 2015, below canopy area, there were two employees working on the ground without a hard hat, exposing themselves to an overhead hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2015-12-14 |
Current Penalty |
1020.0 |
Initial Penalty |
1700.0 |
Final Order |
2015-12-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-sloped roofs with unprotected sides and edges 6 feet (1.8m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line systems and guardrail systems, warning line systems and safety net systems, or warning line systems and personal fall arrest systems, or warning line systems and safety monitoring systems: a. On December 7, 2015, on the flat canopy roof, employees performing roofing work were not protected from a 16 feet fall hazard by the use of a fall protection system. |
|
|
311819239
|
0419700
|
2008-12-01
|
8101 BEACH BLVD, JACKSONVILLE, FL, 32216
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-12-01
|
Emphasis |
L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2009-01-12
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260307 C02 |
Issuance Date |
2008-12-17 |
Abatement Due Date |
2008-12-22 |
Current Penalty |
1000.0 |
Initial Penalty |
1225.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2008-12-17 |
Abatement Due Date |
2008-12-22 |
Current Penalty |
1000.0 |
Initial Penalty |
1225.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2008-12-17 |
Abatement Due Date |
2009-01-14 |
Initial Penalty |
1225.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
05 |
|
|
303993125
|
0419700
|
2003-04-30
|
950 MARSH LANDING PARKWAY, JACKSONVILLE, FL, 32250
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2003-05-12
|
Emphasis |
L: FALL, S: CONSTRUCTION
|
Case Closed |
2003-07-06
|
Related Activity
Type |
Complaint |
Activity Nr |
204382840 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2003-06-10 |
Abatement Due Date |
2003-06-13 |
Current Penalty |
375.0 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19261053 B08 |
Issuance Date |
2003-06-10 |
Abatement Due Date |
2003-06-13 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
|