Entity Name: | MCV CONTRACTING, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
MCV CONTRACTING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 01 Apr 1998 (27 years ago) |
Document Number: | P98000030102 |
FEI/EIN Number |
650825062
Federal Employer Identification (FEI) Number assigned by the IRS. |
Mail Address: | 13950 NW 107 Avenue, Hialeah Gardens, FL, 33018, US |
Address: | 13950 N.W. 107 AVENUE, MIAMI, FL, 33018, US |
ZIP code: | 33018 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
VELAR MANUEL C | President | 13950 N.W. 107 AVENUE, MIAMI, FL, 33018 |
Chou Vivian Esq. | Agent | 13950 N.W. 107 AVENUE, MIAMI, FL, 33018 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REGISTERED AGENT NAME CHANGED | 2019-04-23 | Chou, Vivian, Esq. | - |
CHANGE OF MAILING ADDRESS | 2015-04-06 | 13950 N.W. 107 AVENUE, MIAMI, FL 33018 | - |
CHANGE OF PRINCIPAL ADDRESS | 2008-04-25 | 13950 N.W. 107 AVENUE, MIAMI, FL 33018 | - |
REGISTERED AGENT ADDRESS CHANGED | 2008-04-25 | 13950 N.W. 107 AVENUE, MIAMI, FL 33018 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-25 |
ANNUAL REPORT | 2023-04-24 |
ANNUAL REPORT | 2022-04-27 |
ANNUAL REPORT | 2021-04-23 |
ANNUAL REPORT | 2020-05-21 |
ANNUAL REPORT | 2019-04-23 |
ANNUAL REPORT | 2018-04-03 |
ANNUAL REPORT | 2017-04-17 |
ANNUAL REPORT | 2016-04-19 |
ANNUAL REPORT | 2015-04-06 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347908790 | 0418800 | 2024-12-02 | 9700 COLLINS AVE, BAL HARBOUR, FL, 33154 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2237202 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1790882 |
Safety | Yes |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2023-11-02 |
Related Activity
Type | Referral |
Activity Nr | 2098440 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260250 A01 |
Issuance Date | 2024-04-24 |
Current Penalty | 4115.0 |
Initial Penalty | 6857.0 |
Final Order | 2024-05-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.250(a)(1): Materials stored in tiers were not stacked, racked, blocked, interlocked, or otherwise secured to prevent sliding, falling, or collapse: On or about October 31, 2023, at 930 NE 1st Avenue, Miami, Florida, an employee was exposed to struck-by and caught-between hazards when, in the process of flagging a formwork that was being hoisted, it struck another formwork that was stored but not secured to an A-frame rack, thus falling from the rack an impacting the employee. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-08-17 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2018-03-07 |
Related Activity
Type | Referral |
Activity Nr | 1207624 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1230011 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Other |
Standard Cited | 19260404 B01 I |
Issuance Date | 2017-10-18 |
Abatement Due Date | 2017-10-25 |
Current Penalty | 3621.5 |
Initial Penalty | 7243.0 |
Final Order | 2017-11-22 |
Nr Instances | 2 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. On or about 5/3/2017, at Deck level #39 of the above addressed worksite, the employer had not protected employees from an electrical hazard as evidenced by, among other conditions; a portable saw (Skil, Model SPT2ZW, Serial #505006592) which lacked a ground prong was energized from a non-functioning ground fault circuit interrupter; equipment found to be defective was not tagged to prevent its use and/or daily inspections of equipment connected by cord and plug were not made prior to usage, etc. |
Citation ID | 01001B |
Citaton Type | Other |
Standard Cited | 19260404 F06 |
Issuance Date | 2017-10-18 |
Abatement Due Date | 2017-10-25 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-11-22 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous On or about 5/3/2017, at Deck level #39 of the above addressed worksite, employees were exposed to an electrical hazard while cutting wood with a portable saw (Skil, Model SPT2ZW, Serial #505006592) that lacked a ground prong on its attachment plug. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260701 B |
Issuance Date | 2017-10-18 |
Abatement Due Date | 2017-10-25 |
Current Penalty | 4527.0 |
Initial Penalty | 9054.0 |
Final Order | 2017-11-22 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about 5/3/2017, at Deck level #36 of the above addressed worksite, an employee was exposed to an impalement hazard while setting a deck over an elevator landing which had unguarded rebars on both sides. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1471327106 | 2020-04-10 | 0455 | PPP | 13950 NW 107 Avenue, HIALEAH, FL, 33018-1152 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 01 Apr 2025
Sources: Florida Department of State