Entity Name: | ARTISTRY IN FINISHES, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
ARTISTRY IN FINISHES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 26 Feb 1998 (27 years ago) |
Date of dissolution: | 03 Mar 2023 (2 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 03 Mar 2023 (2 years ago) |
Document Number: | P98000019059 |
FEI/EIN Number |
650828589
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 951 W 13TH STREET, SUITE 7-12, RIVIERA BEACH, FL, 33404, US |
Mail Address: | 951 W 13TH ST, SUITE 9, RIVIERA BEACH, FL, 33404, US |
ZIP code: | 33404 |
County: | Palm Beach |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
TEDESCO CHRISTINE V | Chief Financial Officer | 951 W 13TH ST STE 9, RIVIERA BCH, FL, 33404 |
TEDESCO JOHN P | Chief Executive Officer | 951 W 13TH ST STE 9, RIVIERA BCH, FL, 33404 |
TEDESCO JOHN | Agent | 951 W 13TH ST, RIVIERA BCH, FL, 33404 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2023-03-03 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2019-03-26 | 951 W 13TH STREET, SUITE 7-12, RIVIERA BEACH, FL 33404 | - |
REGISTERED AGENT ADDRESS CHANGED | 2010-02-16 | 951 W 13TH ST, SUITE 9, RIVIERA BCH, FL 33404 | - |
CHANGE OF MAILING ADDRESS | 2009-03-18 | 951 W 13TH STREET, SUITE 7-12, RIVIERA BEACH, FL 33404 | - |
AMENDMENT | 2007-12-04 | - | - |
AMENDMENT | 2005-04-27 | - | - |
AMENDMENT | 2004-04-26 | - | - |
AMENDMENT | 2004-02-20 | - | - |
REGISTERED AGENT NAME CHANGED | 2004-02-02 | TEDESCO, JOHN | - |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2023-03-03 |
ANNUAL REPORT | 2022-02-09 |
ANNUAL REPORT | 2021-02-05 |
ANNUAL REPORT | 2020-02-17 |
ANNUAL REPORT | 2019-03-26 |
ANNUAL REPORT | 2018-03-22 |
ANNUAL REPORT | 2017-01-31 |
ANNUAL REPORT | 2016-03-02 |
ANNUAL REPORT | 2015-03-31 |
ANNUAL REPORT | 2014-03-31 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337071385 | 0418800 | 2012-10-25 | 951 WEST 13TH STREET - BAY 9, RIVIERA BEACH, FL, 33404 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100107 C06 |
Issuance Date | 2013-01-18 |
Abatement Due Date | 2013-02-14 |
Current Penalty | 1000.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-02-15 |
Nr Instances | 2 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) On or about 10-25-2012, at the above addressed jobsite, the 110 volt electrical outlets and switches mounted on the left wall approximately 3 feet from the face of the smaller spray booth were not explosion proof. b) On or about 10-25-2012, at the above addressed jobsite, approximately 4 feet from the front of each spray booth, the fluorescent lights that were suspended from the ceiling were not explosion proof. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2013-01-18 |
Abatement Due Date | 2013-02-07 |
Current Penalty | 800.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 10-25-2012, at the above addressed jobsite, the Crouch Machinery Model 36B Belt Sander was not guarded and exposed the operator to an in-going nip point. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100215 B09 |
Issuance Date | 2013-01-18 |
Abatement Due Date | 2013-02-07 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about 10-25-2012, at the above addressed jobsite, a Grizzly grinder, Model H8126, serial number 7040126, did not have a tongue guard in place on either wheel of the grinder. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100219 C04 I |
Issuance Date | 2013-01-18 |
Abatement Due Date | 2013-02-14 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) On or about 10-25-2012, at the above addressed jobsite, the shaft on the Crouch Machinery Model 36B Belt Sander was unguarded and projected approximately 4 inches above the assemble. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19100242 B |
Issuance Date | 2013-01-18 |
Abatement Due Date | 2013-02-07 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. On or about 10-25-2012, at the above addressed jobsite, in the spray area, an employee was observed using a compressed air in excess of 100 p.s.i. to remove dust. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100107 B05 I |
Issuance Date | 2013-01-18 |
Abatement Due Date | 2013-02-14 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-02-15 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.107(b)(5)(i): There were no visible gauge(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or insure that the required air velocity was maintained: On or about 10-25-2012, at the above addressed jobsite, two spray booths were not equiped with devices to measure the air velocity. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Health |
Close Conference | 2004-01-27 |
Emphasis | N: AMPUTATE, S: AMPUTATIONS |
Case Closed | 2004-03-23 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100213 D01 |
Issuance Date | 2004-01-30 |
Abatement Due Date | 2004-02-26 |
Current Penalty | 225.0 |
Initial Penalty | 375.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 03 |
FTA Current Penalty | 0.0 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2004-01-30 |
Abatement Due Date | 2004-02-26 |
Current Penalty | 225.0 |
Initial Penalty | 375.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 03 |
FTA Current Penalty | 0.0 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100242 B |
Issuance Date | 2004-01-30 |
Abatement Due Date | 2004-02-11 |
Current Penalty | 225.0 |
Initial Penalty | 375.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 03 |
FTA Current Penalty | 0.0 |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19100303 B01 |
Issuance Date | 2004-01-30 |
Abatement Due Date | 2004-02-04 |
Current Penalty | 225.0 |
Initial Penalty | 375.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 03 |
FTA Current Penalty | 0.0 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100134 C01 |
Issuance Date | 2004-01-30 |
Abatement Due Date | 2004-02-26 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 01 |
FTA Current Penalty | 0.0 |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2004-01-30 |
Abatement Due Date | 2004-02-26 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 01 |
FTA Current Penalty | 0.0 |
Date of last update: 03 Mar 2025