Search icon

ARTISTRY IN FINISHES, INC. - Florida Company Profile

Company Details

Entity Name: ARTISTRY IN FINISHES, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ARTISTRY IN FINISHES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 26 Feb 1998 (27 years ago)
Date of dissolution: 03 Mar 2023 (2 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 03 Mar 2023 (2 years ago)
Document Number: P98000019059
FEI/EIN Number 650828589

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 951 W 13TH STREET, SUITE 7-12, RIVIERA BEACH, FL, 33404, US
Mail Address: 951 W 13TH ST, SUITE 9, RIVIERA BEACH, FL, 33404, US
ZIP code: 33404
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TEDESCO CHRISTINE V Chief Financial Officer 951 W 13TH ST STE 9, RIVIERA BCH, FL, 33404
TEDESCO JOHN P Chief Executive Officer 951 W 13TH ST STE 9, RIVIERA BCH, FL, 33404
TEDESCO JOHN Agent 951 W 13TH ST, RIVIERA BCH, FL, 33404

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2023-03-03 - -
CHANGE OF PRINCIPAL ADDRESS 2019-03-26 951 W 13TH STREET, SUITE 7-12, RIVIERA BEACH, FL 33404 -
REGISTERED AGENT ADDRESS CHANGED 2010-02-16 951 W 13TH ST, SUITE 9, RIVIERA BCH, FL 33404 -
CHANGE OF MAILING ADDRESS 2009-03-18 951 W 13TH STREET, SUITE 7-12, RIVIERA BEACH, FL 33404 -
AMENDMENT 2007-12-04 - -
AMENDMENT 2005-04-27 - -
AMENDMENT 2004-04-26 - -
AMENDMENT 2004-02-20 - -
REGISTERED AGENT NAME CHANGED 2004-02-02 TEDESCO, JOHN -

Documents

Name Date
VOLUNTARY DISSOLUTION 2023-03-03
ANNUAL REPORT 2022-02-09
ANNUAL REPORT 2021-02-05
ANNUAL REPORT 2020-02-17
ANNUAL REPORT 2019-03-26
ANNUAL REPORT 2018-03-22
ANNUAL REPORT 2017-01-31
ANNUAL REPORT 2016-03-02
ANNUAL REPORT 2015-03-31
ANNUAL REPORT 2014-03-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337071385 0418800 2012-10-25 951 WEST 13TH STREET - BAY 9, RIVIERA BEACH, FL, 33404
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-10-25
Emphasis L: EISAOF, N: AMPUTATE, P: AMPUTATE
Case Closed 2013-11-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100107 C06
Issuance Date 2013-01-18
Abatement Due Date 2013-02-14
Current Penalty 1000.0
Initial Penalty 1600.0
Final Order 2013-02-15
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) On or about 10-25-2012, at the above addressed jobsite, the 110 volt electrical outlets and switches mounted on the left wall approximately 3 feet from the face of the smaller spray booth were not explosion proof. b) On or about 10-25-2012, at the above addressed jobsite, approximately 4 feet from the front of each spray booth, the fluorescent lights that were suspended from the ceiling were not explosion proof.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2013-01-18
Abatement Due Date 2013-02-07
Current Penalty 800.0
Initial Penalty 2000.0
Final Order 2013-02-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 10-25-2012, at the above addressed jobsite, the Crouch Machinery Model 36B Belt Sander was not guarded and exposed the operator to an in-going nip point.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2013-01-18
Abatement Due Date 2013-02-07
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2013-02-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about 10-25-2012, at the above addressed jobsite, a Grizzly grinder, Model H8126, serial number 7040126, did not have a tongue guard in place on either wheel of the grinder.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2013-01-18
Abatement Due Date 2013-02-14
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-02-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) On or about 10-25-2012, at the above addressed jobsite, the shaft on the Crouch Machinery Model 36B Belt Sander was unguarded and projected approximately 4 inches above the assemble.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2013-01-18
Abatement Due Date 2013-02-07
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2013-02-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. On or about 10-25-2012, at the above addressed jobsite, in the spray area, an employee was observed using a compressed air in excess of 100 p.s.i. to remove dust.
Citation ID 02001
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 2013-01-18
Abatement Due Date 2013-02-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-02-15
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i): There were no visible gauge(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or insure that the required air velocity was maintained: On or about 10-25-2012, at the above addressed jobsite, two spray booths were not equiped with devices to measure the air velocity.
307294744 418800 2004-01-27 951 WEST 13TH STREET - BAY 9, RIVIERA BEACH, FL, 33404
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2004-01-27
Emphasis N: AMPUTATE, S: AMPUTATIONS
Case Closed 2004-03-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100213 D01
Issuance Date 2004-01-30
Abatement Due Date 2004-02-26
Current Penalty 225.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 1
Gravity 03
FTA Current Penalty 0.0
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2004-01-30
Abatement Due Date 2004-02-26
Current Penalty 225.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 1
Gravity 03
FTA Current Penalty 0.0
Citation ID 01003
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2004-01-30
Abatement Due Date 2004-02-11
Current Penalty 225.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 2
Gravity 03
FTA Current Penalty 0.0
Citation ID 01004
Citaton Type Serious
Standard Cited 19100303 B01
Issuance Date 2004-01-30
Abatement Due Date 2004-02-04
Current Penalty 225.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 2
Gravity 03
FTA Current Penalty 0.0
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2004-01-30
Abatement Due Date 2004-02-26
Current Penalty 0.0
Initial Penalty 0.0
Nr Instances 1
Nr Exposed 2
Gravity 01
FTA Current Penalty 0.0
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2004-01-30
Abatement Due Date 2004-02-26
Current Penalty 0.0
Initial Penalty 0.0
Nr Instances 1
Nr Exposed 2
Gravity 01
FTA Current Penalty 0.0

Date of last update: 03 Mar 2025