Search icon

S & S MASONRY OF TAMPA BAY INC. - Florida Company Profile

Company Details

Entity Name: S & S MASONRY OF TAMPA BAY INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

S & S MASONRY OF TAMPA BAY INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 10 Feb 1998 (27 years ago)
Date of dissolution: 27 Sep 2019 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (5 years ago)
Document Number: P98000013166
FEI/EIN Number 593498262

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL, 33544
Mail Address: 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL, 33544
ZIP code: 33544
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
STONEHOCKER MICHAEL H President 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL, 335442418
STONEHOCKER MICHAEL H Agent 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL, 335442418

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
REGISTERED AGENT NAME CHANGED 2009-04-15 STONEHOCKER, MICHAEL H -
REGISTERED AGENT ADDRESS CHANGED 2003-03-17 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL 33544-2418 -
CHANGE OF PRINCIPAL ADDRESS 2002-04-30 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL 33544 -
CHANGE OF MAILING ADDRESS 2002-04-30 26328 GREEN WILLOW RUN, WESLEY CHAPEL, FL 33544 -

Documents

Name Date
ANNUAL REPORT 2018-01-15
ANNUAL REPORT 2017-04-17
ANNUAL REPORT 2016-02-11
ANNUAL REPORT 2015-04-20
ANNUAL REPORT 2014-03-20
ANNUAL REPORT 2013-03-23
ANNUAL REPORT 2012-04-20
ANNUAL REPORT 2011-03-14
ANNUAL REPORT 2010-04-08
ANNUAL REPORT 2009-04-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339593675 0420600 2014-02-21 13810 SHELDON RD, TAMPA, FL, 33624
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-02-21
Emphasis L: FORKLIFT, L: FALL, L: SILICA, P: FALL, N: SILICA
Case Closed 2016-02-03

Related Activity

Type Inspection
Activity Nr 959352
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2014-03-28
Abatement Due Date 2014-04-09
Current Penalty 300.0
Initial Penalty 2000.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. At the site, material handling was conducted by using a GEHL RS6-36 rough terrain forklift without providing the operator with the required training.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2014-03-28
Abatement Due Date 2014-05-14
Current Penalty 400.0
Initial Penalty 2800.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a. At the site, employees were not provided training and education relating to hazards and requirements during masonry wall construction to include issues such as, but not limited to, fall protection, the use of personal protective equipment, scaffolding requirements, masonry wall construction safety to include the setup of a limited access zone requirements and cement block wall bracing for walls over 8 feet high.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-03-28
Abatement Due Date 2014-04-03
Current Penalty 300.0
Initial Penalty 2000.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. At the site, employees were not provided with safety glasses and were exposed to eye injuries while cutting rebar using a saw and while using a mason's trowel to cut wiring used between cement blocks to reinforce the walls.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-03-28
Abatement Due Date 2014-04-03
Current Penalty 1000.0
Initial Penalty 4900.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 3
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. At the second floor, employees were exposed to a fall hazard 11 feet 4 inches, in that, guardrails were not installed at the stairway opening where an extension ladder was placed to access the second floor. b. At the second floor, employees were exposed to a fall hazard 11 feet 4 inches, in that, guardrails were not installed at the north and south material handling areas. c. At the second floor, employees were exposed to a fall hazard 11 feet 4 inches, in that, guardrails were not installed at the elevator shaft doors.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2014-03-28
Current Penalty 1000.0
Initial Penalty 4900.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: a. At the second floor of the building, employees were exposed to a 12 feet fall hazard to the ground below, in that, the window openings which were 8 inches from the walking surface were not provided with standard railings.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2014-03-28
Abatement Due Date 2014-04-03
Current Penalty 300.0
Initial Penalty 2000.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a. At the second floor, employees were exposed to the hazard of impalement, in that, protruding rebar was not capped throughout the entire second story where masonry wall construction was in progress also rebar was not capped at material handling areas and on window openings.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260706 A01
Issuance Date 2014-03-28
Abatement Due Date 2014-04-03
Current Penalty 700.0
Initial Penalty 3500.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.706(a)(1): A limited access zone was not established prior to the start of construction of a masonry wall: a. At the site, employees were not protected from newly constructed masonry block walls by establishing a limited access zone at the unscaffolded side.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-03-28
Abatement Due Date 2014-05-14
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) a. On site, employees were exposed to gasoline and masonry cement containing silicates during cement block wall construction, in that, a written hazard communication program was not developed, maintained and implemented at the workplace.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2014-03-28
Abatement Due Date 2014-04-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical which they used: (Construction Reference: 1926.59) a. On site, employees were exposed to gasoline and masonry cement containing silicates during cement block wall construction. Material Safety Data Sheets were not maintained at the workplace to provide employees information on the hazardous chemicals used.
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2014-03-28
Abatement Due Date 2014-05-14
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a. On site, employees were exposed to gasoline and masonry cement containing silicates during cement block wall construction. The employees were not provided training and education on the hazardous chemicals at the workplace.
Citation ID 02004
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2014-03-28
Abatement Due Date 2014-05-14
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a written safety and health program to address the company policy on safety as well as the employer/employee responsibilities.
Citation ID 02005
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2014-03-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a. At the site, employees were exposed to electrical hazards, in that, a yellow extension cord used to provide power to portable power tools had the ground prong broken off.
Citation ID 02006
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2014-03-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 14
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a. At the site, employees were exposed to electrical hazards, in that, a yellow extension cord used to provide power to portable power tools was frayed.
Citation ID 02007
Citaton Type Other
Standard Cited 19260452 C02
Issuance Date 2014-03-28
Abatement Due Date 2014-04-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-04-21
Final Order 2015-12-04
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a. At the second floor, employees were exposed to fall hazards, in that, single frame scaffolding was used with cross braces only on the one side.

Date of last update: 02 Mar 2025

Sources: Florida Department of State