Search icon

LAURIES GENERAL WELDING, INC. - Florida Company Profile

Company Details

Entity Name: LAURIES GENERAL WELDING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

LAURIES GENERAL WELDING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 02 Feb 1998 (27 years ago)
Date of dissolution: 19 Sep 2003 (21 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 19 Sep 2003 (21 years ago)
Document Number: P98000010416
FEI/EIN Number 650814033

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 11350 NW SOUTH RIVER DR., MEDLEY, FL, 33178
Mail Address: 11350 NW SOUTH RIVER DR., MEDLEY, FL, 33178
ZIP code: 33178
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LAURIES PAULO President 1801 SW 93 CT., MIAMI, FL, 33165
MAYEA OLGA MAYRA Secretary 5505 NW 172 TERR., MIAMI, FL, 33055
LAURIES PAULO Agent 1801 S.W. 93 COURT, MIAMI, FL, 33165

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2003-09-19 - -
CHANGE OF PRINCIPAL ADDRESS 2000-07-13 11350 NW SOUTH RIVER DR., MEDLEY, FL 33178 -
CHANGE OF MAILING ADDRESS 2000-07-13 11350 NW SOUTH RIVER DR., MEDLEY, FL 33178 -
REGISTERED AGENT ADDRESS CHANGED 2000-07-13 1801 S.W. 93 COURT, MIAMI, FL 33165 -
NAME CHANGE AMENDMENT 2000-05-03 LAURIES GENERAL WELDING, INC. -

Documents

Name Date
ANNUAL REPORT 2002-05-21
ANNUAL REPORT 2001-05-10
ANNUAL REPORT 2000-07-13
Name Change 2000-05-03
ANNUAL REPORT 1999-09-01
Domestic Profit 1998-02-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346519440 0418800 2023-02-21 11350 NW SOUTH RIVER DR, MEDLEY, FL, 33178
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2023-02-22

Related Activity

Type Accident
Activity Nr 2001416

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100252 A01 I
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(1)(i):The object to be welded or cut could not readily be moved, all movable fire hazards in the vicinity were not taken to a safe place: On or about February 21, 2023, in the shop, employees were exposed to fire and explosion hazards while welding activities were performed in a tanker truck with gas vapors and Heavy Petroleum Distillate (HPD).
Citation ID 01002
Citaton Type Serious
Standard Cited 19100252 A02 III A 1
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(2)(iii)(A)(1): The employer did not provide fire watchers whenever welding or cutting was performed, where appreciable combustible material in building construction or contents was closer than 35 feet (10.7 m) to the point of operation: On or about February 21, 2023, in the shop, employees were performing welding activity without a fire watch, exposing employees to a fire hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100252 A02 XIII
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(2)(xiii): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment on its property, in accordance with 29 CFR 1910.252 (a)(2)(xiii)(A) through 29 CFR 1910.252(a)(2)(xiii)(D): On or about February 21, 2023, in the shop, employees were exposed to fire and explosion hazards while welding activities were performed without recognizing the lack of work protocols, fire extinguisher and gas vapor detector equipment.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100252 A03 I
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(3)(i): Welding, cutting, or other hot work was performed on used drums, barrels, tanks, or other containers that had not been cleaned so thoroughly as to make absolutely certain there were no flammable materials present or any substances such as greases, tars, acids, or other materials which when subjected to heat, might produce flammable or toxic vapors: On or about February 21, 2023, an employee was performing welding activity on a tank that had gasoline and vapors still present, exposing employees to a fire and explosion hazard.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100252 A03 II
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(3)(ii): All hollow spaces, cavities, or containers were not vented to permit the escape of air or gases before preheating, cutting, or welding was performed: On or about February 21, 2023, in the shop, employees were exposed to fire and explosion hazards while welding without venting the gas vapors inside the tank.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100254 A03
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.254(a)(3): Workmen designated to operate arc welding equipment had not been properly instructed and qualified to operate such equipment as specified in paragraph (d) of this section: On or about February 21, 2023, in the shop, employees were exposed to fire and explosion hazards while the welder was not properly qualified to perform work and take the basic precautions of fire prevention and protection.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100178 L06
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 3349.0
Initial Penalty 3349.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by paragraph (l) through a certification that included the name of the operator, the date of the training, that date of evaluation, and the identity of the person(s) performing the training or evaluation: On or about February 21, 2023, in the shop, employees were exposed to struck by hazard when the forklift was operated by an untrained and uncertified employee.
Citation ID 02001A
Citaton Type Other
Standard Cited 19100252 C01 IV
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(c)(1)(iv): The employer did not include the potentially hazardous materials employed in fluxes, coatings, coverings, and filler metals, all of which are potentially used in welding and cutting, in the program established to comply with Hazard Communication Standard (HCS) (sec. 1910.1200): On or about February 21, 2023, in the shop, employees were exposed to toxic fumes while performing welding without a written Hazard Communication Program.
Citation ID 02001B
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: On or about February 21, 2023, in the shop employees were exposed to toxic fumes while performing welding without a written Hazard Communication Program.
Citation ID 02002
Citaton Type Other
Standard Cited 19100252 A02 II
Issuance Date 2023-08-18
Abatement Due Date 2023-09-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-10-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(a)(2)(ii): Suitable extinguishing equipment was not maintained in a state of readiness for instant use. Such equipment may consist of pails of water, buckets of sand, hose or portable extinguishers depending upon the nature and quantity of the combustible material exposed: On or about February 21, 2023, in the shop, the employer did not have fire extinguishers available for employees performing welding activities.

Date of last update: 02 Feb 2025

Sources: Florida Department of State