Entity Name: | G & S CONCRETE, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
G & S CONCRETE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 26 Dec 1997 (27 years ago) |
Date of dissolution: | 25 Jul 2016 (9 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 25 Jul 2016 (9 years ago) |
Document Number: | P97000108264 |
FEI/EIN Number |
593489991
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 3205 TANGLEWOOD DR., SARASOTA, FL, 34239 |
Mail Address: | 3205 TANGLEWOOD DR., SARASOTA, FL, 34239 |
ZIP code: | 34239 |
County: | Sarasota |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
VASTOLA GLORIA | President | 3205 TANGLEWOOD DR., SARASOTA, FL, 34239 |
VASTOLA SAL | Vice President | 3205 TANGLEWOOD DR., SARASOTA, FL, 34239 |
VASTOLA SAL | Agent | 3205 TANGLEWOOD DR., SARASOTA, FL, 34239 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2016-07-25 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2014-09-26 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J09000010578 | LAPSED | 08-15321-J | HILLSBOROUGH CTY. CT. | 2008-11-10 | 2014-01-15 | $1,190.99 | CEMEX, INC., C/O 1100 MAIN ST., BUFFALO, NY 14209 |
Name | Date |
---|---|
VOLUNTARY DISSOLUTION | 2016-07-25 |
ANNUAL REPORT | 2013-04-21 |
ANNUAL REPORT | 2012-01-21 |
ANNUAL REPORT | 2011-02-18 |
ANNUAL REPORT | 2010-03-31 |
ANNUAL REPORT | 2009-04-27 |
ANNUAL REPORT | 2008-09-26 |
ANNUAL REPORT | 2007-07-11 |
ANNUAL REPORT | 2006-02-21 |
ANNUAL REPORT | 2005-03-29 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337715627 | 0420600 | 2012-12-06 | 1904 E. S.R. 60, VALRICO, FL, 33594 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 771663 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2012-12-10 |
Current Penalty | 1700.0 |
Initial Penalty | 1700.0 |
Final Order | 2013-01-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. On or about 12/06/2012, at the job site - an employee making holes in the wall to install metal brace plates was permitted to work from a scaffold that was not fully planked, exposing them to an 8 feet 9 inches fall hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2012-12-10 |
Abatement Due Date | 2012-12-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-01-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a. On or about 12/06/2012, at the job site - the employer did not ensure that all the employees working from the scaffold were trained recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards, exposing the employees to an 8 feet 9 inches fall hazard. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 1985-07-18 |
Case Closed | 1985-07-18 |
Date of last update: 02 Apr 2025
Sources: Florida Department of State