Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-12-13
|
Emphasis |
N: AMPUTATE
|
Related Activity
Type |
Complaint |
Activity Nr |
2109176 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100106 E02 II B 2 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
4018.0 |
Initial Penalty |
4018.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of Category 2, 3 or 4 flammable liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons: a) For the storage of flammable chemicals on the shop floor adjacent to the spray room/booth, on or about 12/13/2023, the employer exposed employees to fire hazards, in that approximately 350 gallons of category 2 flammable liquids were stored in the shop area outside of a flammable storage cabinet or flammable inside storage room. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 IV |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
2679.0 |
Initial Penalty |
2679.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) For the spray booth area, as observed on or about 12/13/2023, the employer exposed employees to fire hazards, in that, there were no automatic sprinklers or other approved automatic fire extinguishment means on the upstream and downstream sides of the filters. A handheld spraying operation was in place with flammable paints. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100107 B10 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
2679.0 |
Initial Penalty |
2679.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(10): 29 CFR 1910.107(b)(10): Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit is located. a) For the spray booth area, as observed on or about 12/13/2023, the employer exposed employees to fire hazards, in that, hard wired LED lighting on the ceiling of the spray area was not protected by illumination panels, nor were the lights explosion proof. Employees hand sprayed flammable paints in the spray area. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
2009.0 |
Initial Penalty |
2009.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) For the paint room/booth, on or about 12/13/2023, the employer exposed employees to respiratory hazards, in that, a 3M half-face respirator was required to be worn by employees while spray painting, and the employer did not have a written and implemented respiratory protection program. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2024-01-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) For the paint room/booth, on or about 12/13/2023, the employer exposed employees to respiratory hazards, in that, a 3M half-face respirator was required to be worn by employees while spray painting, and the employer had not provided a medical evaluation to determine the employee's ability to use a respirator. |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) For the paint room/booth, on or about 12/13/2023, the employer exposed employees to respiratory hazards, in that, a 3M half-face respirator was required to be worn by employees while spray painting, and the employer had not ensured that employee(s) required to use the half-face respirator were fit tested. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
4018.0 |
Initial Penalty |
4018.0 |
Final Order |
2024-02-08 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) For the chemical storage area adjacent to the spray booth/room, on or about 12/13/2023, the employer exposed employees to corrosive eye and skin hazards, in that, employees used M.L. Campbell Care Catalyst which was an eye and skin corrosive chemical, and no eyewash station and shower were present for suitable drenching or flushing of the eyes and body upon exposure to the corrosive. b) For the chemical storage area adjacent to the spray booth/room, on or about 12/13/2023, the employer exposed employees to corrosive eye hazards, in that, employees used varnishes and coatings that were corrosive to the eyes, and no eyewash station was present for suitable flushing of the eyes upon exposure to the corrosives. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2024-01-03 |
Current Penalty |
2679.0 |
Initial Penalty |
2679.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i):The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a) For the cabinet facility/shop, on or about 12/13/2023, the employer exposed employees to struck-by hazards, in that, forklift operators had not been trained and evaluated for forklift operation/safety within the last three years. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) For the table saw used to cut laminate material on the shop floor, on or about 12/13/2023, the employer exposed employees to cut and amputation hazards, in that, the saw blade was not guarded from incidental contact at a blade height of 1 and 3/4 inches above the table. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) For the wood cutting table saw, on or about 12/13/2023, the employer exposed employees to laceration and amputation hazards, in that, employees used the table saw to rip cut wood pieces without any blade guard/hood in place. The blade was used at a height of 1 and 1/4 inches above the saw's table. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100213 C02 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Handfed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) For the wood cutting table saw, on or about 12/13/2023, the employer exposed employees to laceration and puncture/projectile hazards, in that, employees used the table saw to rip cut wood pieces without a spreader in place to prevent material from being thrown back at operator. The blade was used at a height of 1 and 1/4 inches above the saw's table. |
|
Citation ID |
01008C |
Citaton Type |
Serious |
Standard Cited |
19100213 C03 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) For the wood cutting table saw, on or about 12/13/2023, the employer exposed employees to laceration and projectile/puncture hazards, in that, employees used the table saw to rip cut wood pieces without any non kickback fingers/dogs in place to inhibit material from being thrown back towards the operator. The blade was used at a height of 1 and 1/4 inches above the saw's table. |
|
Citation ID |
01008D |
Citaton Type |
Serious |
Standard Cited |
19100213 D01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) For the wood cutting table saw, on or about 12/13/2023, the employer exposed employees to laceration and amputation hazards, in that, employees used the table saw to cross cut wood pieces without any blade guard/hood in place. The blade was used at a height of 1 and 1/4 inches above the saw's table. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) For the spray booth area, on or about 12/13/2023, the employer exposed employees to compressed air hazards and the potential for an embolism, in that, compressed air was used for cleaning at dead front pressures of 61 p.s.i. |
|
Citation ID |
01010A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
4018.0 |
Initial Penalty |
4018.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) For the cabinet shop, on or about 12/13/2023, the employer exposed employees to fire and corrosive contact hazards, in that, employees used hazardous chemicals in the form of varnishes, coatings and catalysts, and a written hazard communication program for chemicals used was not up to date with the chemicals used and implemented. |
|
Citation ID |
01010B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): a) For the cabinet shop, on or about 12/13/2023, the employer exposed employees to fire and corrosive contact hazards, in that, employees used hazardous chemicals in the form of varnishes, coatings and catalysts, and safety data sheets were not present and available for each hazardous chemical used. |
|
Citation ID |
01010C |
Citaton Type |
Serious |
Standard Cited |
19101200 H02 III |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(2)(iii): The employer did not provide information to the employees as to the location and availability of the written hazard communication program, and material safety data sheets required by 29 CFR 1910.1200: a) For the cabinet shop, on or about 12/13/2023, the employer exposed employees to fire and corrosive contact hazards, in that, employees used hazardous chemicals in the form of varnishes, coatings and catalysts, and had not been provided information as to the location and availability of a written hazard communication program and safety data sheets. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100107 B05 I |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-02-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained. a) For the paint spray booth area, on or about 12/13/2023, the paint spray booth/area ventilation was not equipped with any visible gauge, alarm or other device to indicate that the required air speed was maintained. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100107 G07 |
Issuance Date |
2024-01-03 |
Abatement Due Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-08 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(g)(7):"NO SMOKING" sign(s) in large letters on contrasting color backgrounds were not conspicuously posted at spraying area(s) and paint storage room(s): For the paint spraying area and storage area, on or about 12/13/2023, the employer exposed employees to potential fire hazards, in that, "No Smoking" signs were not conspicuously posted. |
|
|