Entity Name: | DORADUS CORP. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
DORADUS CORP. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 03 Oct 1997 (27 years ago) |
Document Number: | P97000085973 |
FEI/EIN Number |
593472464
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 10825 TOM FOLSOM ROAD, SUITE A, THONOTOSASSA, FL, 33592-3456, US |
Mail Address: | 10825 TOM FOLSOM ROAD, SUITE A, THONOTOSASSA, FL, 33592-3456, US |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
MACDONALD HUGH J | President | 10825 TOM FOLSOM ROAD, THONOTOSASSA, FL, 335923456 |
MacDonald III Hugh | Vice President | 10825 TOM FOLSOM ROAD, THONOTOSASSA, FL, 335923456 |
MACDONALD HUGH J | Agent | 10825 TOM FOLSOM ROAD, THONOTOSASSA, FL, 335923456 |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G10000037035 | ALVAREZ ROOFING | ACTIVE | 2010-04-27 | 2025-12-31 | - | 10825 TOM FOLSOM ROAD, SUITE A, THONOTOSASSA, FL, 33592 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2015-02-02 | 10825 TOM FOLSOM ROAD, SUITE A, THONOTOSASSA, FL 33592-3456 | - |
CHANGE OF MAILING ADDRESS | 2015-02-02 | 10825 TOM FOLSOM ROAD, SUITE A, THONOTOSASSA, FL 33592-3456 | - |
REGISTERED AGENT ADDRESS CHANGED | 2015-02-02 | 10825 TOM FOLSOM ROAD, SUITE A, THONOTOSASSA, FL 33592-3456 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-29 |
ANNUAL REPORT | 2023-03-14 |
ANNUAL REPORT | 2022-03-11 |
ANNUAL REPORT | 2021-01-28 |
ANNUAL REPORT | 2020-02-10 |
ANNUAL REPORT | 2019-04-09 |
ANNUAL REPORT | 2018-02-02 |
ANNUAL REPORT | 2017-01-30 |
ANNUAL REPORT | 2016-01-15 |
ANNUAL REPORT | 2015-02-02 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343504189 | 0420600 | 2018-09-26 | 15017 BLUE QUAKER PLACE, TAMPA, FL, 33601 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-03-11 |
Current Penalty | 3182.4 |
Initial Penalty | 5304.0 |
Final Order | 2019-04-01 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) roof - seven employees were exposed to a fall of 19 feet 9 inches while installing shingles, on or about 9/26/18. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-03-11 |
Current Penalty | 1818.6 |
Initial Penalty | 3031.0 |
Final Order | 2019-04-01 |
Nr Instances | 1 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) roof - seven employees were exposed to a fall of 9 feet 4 inches while using a ladder that was not 3 feet above the landing. The ladder was approximately 1 1/2 feet above the landing, on or about 9/26/18. |