Search icon

PORCELANOSA FLORIDA CORPORATION - Florida Company Profile

Company Details

Entity Name: PORCELANOSA FLORIDA CORPORATION
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PORCELANOSA FLORIDA CORPORATION is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 May 1997 (28 years ago)
Date of dissolution: 05 Dec 2017 (7 years ago)
Last Event: CORPORATE MERGER
Event Date Filed: 05 Dec 2017 (7 years ago)
Document Number: P97000044276
FEI/EIN Number 650780648

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 153 SEVILLA AVENUE, CORAL GABLES, FL, 33134, US
Mail Address: PO BOX 140668, CORAL GABLES, FL, 33114, US
ZIP code: 33134
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SORIANO MARIA JOSE President CTRA. N-340 KM. 56, VILLARREAL, ESPANA, CA, 12540
COLONQUES HECTOR Secretary CTRA. N-340 KM. 56, VILLARREAL, ESPANA, CA, 12540
RAMOS JUAN F Treasurer CTRA. N-340 KM. 56, VILLARREAL, ESPANA, CA, 12540
FREEMAN MICHAEL J Vice President 153 SEVILLA AVE, CORAL GABLES, FL, 33134
FREEMAN MICHAEL J Assistant Secretary 153 SEVILLA AVE, CORAL GABLES, FL, 33134
SEGARRA SILVESTRE Executive Vice President CTRA. N-340 KM. 56, VILLARREAL, ESPANA, CA, 12540
MJF REGISTERED AGENT CORP Agent 153 SEVILLA AVENUE, CORAL GABLES, FL, 33134

Events

Event Type Filed Date Value Description
MERGER 2017-12-05 - CORPORATION WAS PART OF A MERGER. NON-QUALIFIED CORPORATION WAS PORVEN, LTD., A DELAWARE PROFIT COR. MERGER NUMBER 700000176567
CHANGE OF PRINCIPAL ADDRESS 2003-02-24 153 SEVILLA AVENUE, CORAL GABLES, FL 33134 -
CHANGE OF MAILING ADDRESS 2001-03-12 153 SEVILLA AVENUE, CORAL GABLES, FL 33134 -
REGISTERED AGENT NAME CHANGED 2001-03-12 MJF REGISTERED AGENT CORP -
REGISTERED AGENT ADDRESS CHANGED 2001-03-12 153 SEVILLA AVENUE, CORAL GABLES, FL 33134 -

Documents

Name Date
Merger 2017-12-05
ANNUAL REPORT 2017-02-21
ANNUAL REPORT 2016-03-25
ANNUAL REPORT 2015-03-18
ANNUAL REPORT 2014-03-12
ANNUAL REPORT 2013-02-11
ANNUAL REPORT 2012-03-29
ANNUAL REPORT 2011-01-24
ANNUAL REPORT 2010-04-08
ANNUAL REPORT 2009-03-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341383693 0418800 2016-04-07 8700 NW 13TH TER, DORAL, FL, 33172
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2016-04-07
Emphasis N: SILICA, L: HINOISE, P: SILICA
Case Closed 2016-08-26

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 1512.0
Initial Penalty 2520.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about 04/07/2016 , at the address jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not establish and implement a written respiratory protection program for employees required to wear 3M Particulate Respirator 8210, N95 in the workplace.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about 04/07/2016 , at the address jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not provide a medical evaluation for employees who had to wear a 3M Particulate Respirator 8210, and/or an N95 filtering facepiece respirator in the workplace.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: On or about 04/07/2016 , at the address jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not provide a fit-test prior to having employees wear a filtering facepiece air purifying respirator.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 K01 I
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(1)(i): The employer did not ensure that each employee could demonstrate knowledge of why the respirator was necessary and how improper fit, usage, or maintenance could compromise the protective effect of the respirator: On or about 04/07/2016 , at the address jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not ensure that employees who are required to wear a 3M Particulate Respirator 8210, and/or N95 filtering facepiece respirator were able to wear the respirator properly, know why proper fit is necessary, and how maintenance could compromise the protective effect of the respirator.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19101000 C
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 1944.0
Initial Penalty 3240.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(c): An employee(s) was exposed to (IDENTIFY MATERIAL) in excess of the 8-hour time weighted average limits of (INCLUDE APPROPRIATE VALUE FROM TABLE) listed in Table Z-3: On or about April 7th, 2016, at the jobsite located at 8700 NW 13th Ter. Doral, FL 33172, an employee engaged in cutting tiles and granite was over-exposed to respirable silica dust at a concentration of 0.93 mg/m3 expressed as an 8 hour time-weighted average of 3 times the daily Permissible Exposure Limit (PEL) of 0.31 mg/m3 based on a 175 minute sampling period; exposure calculations included a zero-increment for the 305 minutes not sampled.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19101000 E
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): On or about April 7th, 2016, at the jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not implement feasible administrative or engineering controls while an employee engaged in cutting tiles and granite was over-exposed to respirable silica dust at a concentration of 0.93 mg/m3 expressed as an 8 hour time-weighted average of 3 times the daily Permissible Exposure Limit (PEL) of 0.31 mg/m3 based on a 175 minute sampling period; exposure calculations included a zero-increment for the 305 minutes not sampled.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 1944.0
Initial Penalty 3240.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about April 7th, 2016, at the jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not develop and implement a written hazard communication program for employees who are exposed to hazardous chemicals such as, but not limited to silica when performing cutting of tiles and stones.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about April 7th, 2016, at the jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not provide training for employees who are exposed to hazardous chemicals such as, but not limited to silica when performing cutting of tiles and stones.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101200 H03 IV
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: On or about April 7th, 2016, at the jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not provide training to employees about the chemical hazards present at the workplace in accordance with the Globally Harmonized System of Classification and Labeling of Chemicals with pictograms or representations as a part of the new SDS and label format.
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 A01
Issuance Date 2016-07-27
Abatement Due Date 2016-08-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-09
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. On or about 04/07/2016 , at the address jobsite located at 8700 NW 13th Ter. Doral, FL 33172, the employer did not ensure that power cords were used in an orderly manner, exposing employees to a tripping hazard.