Entity Name: | J. ED MAY ROOFING, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
J. ED MAY ROOFING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 01 May 1997 (28 years ago) |
Date of dissolution: | 01 Jun 2018 (7 years ago) |
Last Event: | CONVERSION |
Event Date Filed: | 01 Jun 2018 (7 years ago) |
Document Number: | P97000038894 |
FEI/EIN Number |
82-5181442
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 9913 S. US Hwy 41, Gibsonton, FL, 33534, US |
Mail Address: | 9913 S. US Hwy 41, Gibsonton, FL, 33534, US |
ZIP code: | 33534 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Choe Ji Woong | President | 9913 S. US Hwy 41, Gibsonton, FL, 33534 |
WCCR, PLLC | Agent | - |
Registration Number | Fictitious Name | Status | Filed Date | Expiration Date | Cancellation Date | Mailing Address |
---|---|---|---|---|---|---|
G11000113388 | CUSTOM ROOFING & REPAIRS | EXPIRED | 2011-11-22 | 2016-12-31 | - | PO BOX 551, RUSKIN, FL, 33575 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CONVERSION | 2018-06-01 | - | CONVERSION MEMBER. RESULTING CORPORATION WAS L18000137042. CONVERSION NUMBER 500000182565 |
REGISTERED AGENT ADDRESS CHANGED | 2018-05-14 | 9913 S. US Hwy 41, Gibsonton, FL 33534 | - |
CHANGE OF PRINCIPAL ADDRESS | 2018-05-14 | 9913 S. US Hwy 41, Gibsonton, FL 33534 | - |
CHANGE OF MAILING ADDRESS | 2018-05-14 | 9913 S. US Hwy 41, Gibsonton, FL 33534 | - |
REGISTERED AGENT NAME CHANGED | 2018-05-14 | WCCR | - |
CONVERSION | 2017-06-29 | - | CONVERSION MEMBER. RESULTING CORPORATION WAS L17000141619. CONVERSION NUMBER 700000172617 |
REINSTATEMENT | 2017-06-02 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2016-09-23 | - | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J10000975190 | LAPSED | 08-17095-CI13 | 6TH JUDICIAL, PINELLAS COUNTY | 2010-09-24 | 2015-10-12 | $32,735.88 | BRADCO SUPPLY CORPORATION, 6944 NORTH US HWY 41, APOLLO BEACH, FL 33572 |
Name | Date |
---|---|
ANNUAL REPORT | 2018-05-14 |
REINSTATEMENT | 2017-06-02 |
ANNUAL REPORT | 2015-03-20 |
ANNUAL REPORT | 2014-03-21 |
ANNUAL REPORT | 2013-04-01 |
ANNUAL REPORT | 2012-01-09 |
ANNUAL REPORT | 2011-02-12 |
ANNUAL REPORT | 2010-02-20 |
ANNUAL REPORT | 2009-03-27 |
ANNUAL REPORT | 2008-01-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340697648 | 0420600 | 2015-06-10 | 11525 BIG BEND RD, RIVERVIEW, FL, 33579 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2015-06-30 |
Abatement Due Date | 2015-07-13 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-07-13 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) For employees working at 11525 Big Bend Road in Riverview, as observed on or about June 10, 2015. Employees were installing roofing materials on a low slope roof greater than 50 feet in width, without the use of a fall protection system. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2015-06-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-07-13 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) For employees working at 11525 Big Bend Road, as observed on or about June 10, 2015. Employees were using an extension ladder to access the upper work surface with the side rails not extended a minimum of 3 feet above the upper working surface. The ladder side rails extended approximately 25 inches above the upper landing surface. |
Date of last update: 02 Mar 2025