Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-11-18
|
Emphasis |
L: EISAOF, L: EISAX, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2015-01-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2015-01-15 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-12-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. At the mixer area, employees were exposed to the point of operation of the Hobart mixer, in that, a guard was not provided over the mixing bowl to protect employees form the moving parts. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2014-12-03 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-12-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. Kitchen area, employees were exposed to an electrical hazard, in that, a 4-way outlet box used to operate equipment on the food preparation counter did not have a cover. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2014-12-03 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-12-04 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. At the mixer area, employees were exposed to an electrical hazard, in that, the wiring to the Hobart 140 quart mixer was not provided with strain relief. b. At the mixer area, employees were exposed to an electrical hazard, in that, the plug to the Kemblex machine had the outer sheath of the insulation pulled from the plug and was not provided with strain relief. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2014-12-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-12-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. At the dining area, employees were exposed to an electrical hazard, in that, a three way extension cord was used in place of fixed wiring to provide power to the refrigerated glass case. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2015-01-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-12-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. At the site, employees were exposed to chemical products such as, but not limited to, Swisher Bio Rinse containing alkoxylated alcohols, Swisher Bio Clean containing sodium hydroxide, bleach and Lime-a-Way used during dishwashing and surface area cleaning and disinfecting. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2015-01-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-12-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a. At the site, employees were exposed to chemical products such as, but not limited to, Swisher Bio Rinse containing alkoxylated alcohols, Swisher Bio Clean containing sodium hydroxide, bleach and Lime-a-Way used during dishwashing and surface area cleaning and disinfecting. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2014-11-26 |
Abatement Due Date |
2015-01-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-12-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. At the site, employees were exposed to chemical products such as, but not limited to, Swisher Bio Rinse containing alkoxylated alcohols, Swisher Bio Clean containing sodium hydroxide, bleach and Lime-a-Way used during dishwashing and surface area cleaning and disinfecting. |
|
|