Search icon

PRECISION METAL INDUSTRIES, INC. - Florida Company Profile

Company Details

Entity Name: PRECISION METAL INDUSTRIES, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PRECISION METAL INDUSTRIES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 26 Apr 1996 (29 years ago)
Last Event: AMENDMENT
Event Date Filed: 06 Jun 2003 (22 years ago)
Document Number: P96000036253
FEI/EIN Number 650682405

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
Mail Address: 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
ZIP code: 33069
County: Broward
Place of Formation: FLORIDA

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2023 650682405 2024-09-26 PRECISION METAL INDUSTRIES, INC. 104
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2022 650682405 2023-09-29 PRECISION METAL INDUSTRIES, INC. 102
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2021 650682405 2022-10-17 PRECISION METAL INDUSTRIES, INC. 115
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2020 650682405 2021-10-04 PRECISION METAL INDUSTRIES, INC. 94
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2019 650682405 2020-09-22 PRECISION METAL INDUSTRIES, INC. 90
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2018 650682405 2019-10-08 PRECISION METAL INDUSTRIES, INC. 90
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2017 650682405 2018-09-19 PRECISION METAL INDUSTRIES, INC. 91
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2016 650682405 2017-08-30 PRECISION METAL INDUSTRIES, INC. 89
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2015 650682405 2016-08-29 PRECISION METAL INDUSTRIES, INC. 86
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512
PRECISION METAL INDUSTRIES RETIREMENT SAVINGS PLAN 2014 650682405 2015-10-14 PRECISION METAL INDUSTRIES, INC. 94
File View Page
Three-digit plan number (PN) 002
Effective date of plan 2003-03-17
Business code 332900
Sponsor’s telephone number 9549426303
Plan sponsor’s address 1408 SW 8 STREET, POMPANO BEACH, FL, 330694512

Signature of

Role Plan administrator
Date 2015-10-14
Name of individual signing GREGORY S WILSON
Valid signature Filed with authorized/valid electronic signature

Key Officers & Management

Name Role Address
WILSON GREGORY Chairman 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
WILSON GREGORY SJr. President 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
Larkin Timothy J Director 1408 SW 8th Street, Pompano Beach, FL, 33069
Raley Roy L Director 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
Hornick Robert Vice President 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
Hornick Robert o 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069
WILSON GREGORY Jr. Agent 1408 S.W. 8TH STREET, POMPANO BEACH, FL, 33069

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2024-01-11 WILSON , GREGORY, Jr. -
AMENDMENT 2003-06-06 - -

Documents

Name Date
ANNUAL REPORT 2025-01-09
AMENDED ANNUAL REPORT 2024-01-15
ANNUAL REPORT 2024-01-11
ANNUAL REPORT 2023-01-13
ANNUAL REPORT 2022-01-11
ANNUAL REPORT 2021-01-13
ANNUAL REPORT 2020-01-15
ANNUAL REPORT 2019-01-22
ANNUAL REPORT 2018-01-25
ANNUAL REPORT 2017-01-18

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
DEFINITIVE CONTRACT AWARD W31P4Q17C0110 2017-05-24 2022-04-30 2022-04-30
Unique Award Key CONT_AWD_W31P4Q17C0110_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 4420686.00
Current Award Amount 4420686.00
Potential Award Amount 4989870.00

Description

Title JOINT-AIR-TO-GROUND MISSILES (JAGM) SHIPPING AND STORAGE CONTAINERS
NAICS Code 336419: OTHER GUIDED MISSILE AND SPACE VEHICLE PARTS AND AUXILIARY EQUIPMENT MANUFACTURING
Product and Service Codes 8145: SPECIALIZED SHIPPING AND STORAGE CONTAINERS

Recipient Details

Recipient PRECISION METAL INDUSTRIES, INC.
UEI M7T9H9T81ZH9
Recipient Address UNITED STATES, 1408 SW 8TH ST, POMPANO BEACH, BROWARD, FLORIDA, 330694512

USAspending Awards. Financial Assistance

FAIN Awarding Agency Assistance Listings Start Date End Date Description
3666875005 Small Business Administration 59.041 - 504 CERTIFIED DEVELOPMENT LOANS - - TO ASSIST SMALL BUSINESS CONCERNS BY PROVIDING LONG TERM FINANCING THROUGH THE SALE OF DEBENTURES TO THE PRIVATE SECTOR
Recipient PRECISION METAL INDUSTRIES INC.
Recipient Name Raw PRECISION METAL INDUSTRIES INC.
Recipient Address 1410 SOUTHWEST 8TH STREET., POMPANO BEACH, BROWARD, FLORIDA, 33069-0000, UNITED STATES
Obligated Amount 0.00
Non-Federal Funding 0.00
Original Subsidy Cost 0.00
Face Value of Direct Loan 0.00
Link View Page

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342517406 0418800 2017-08-02 1408 SW 8TH STREET, POMPANO BEACH, FL, 33069
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-11-08
Emphasis N: AMPUTATE, L: FORKLIFT, P: AMPUTATE
Case Closed 2018-02-26

Related Activity

Type Referral
Activity Nr 1248204
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2017-12-20
Abatement Due Date 2018-01-25
Current Penalty 5323.8
Initial Penalty 8873.0
Final Order 2018-01-11
Nr Instances 8
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about 8/2/2017, at the press brake department of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a press brake (i.e. Omada, Model RG-80, Serial #5050010) that had its point of operation not guarded. b. On or about 8/2/2017, at the press brake department of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a press brake (i.e. Omada, Model RG, Serial #804673) that had its point of operation not guarded. c. On or about 8/2/2017, at the welding department of the above addressed jobsite, an employee was exposed to a caught by hazard while working with a lathe (i.e. Cadillac, Model 1440C) that had its point of operation not guarded. d. On or about 8/2/2017, at the model shop of the addressed worksite, an employee was exposed to a caught by hazard while working with a drill press (i.e. Clausing, Model 1634, Serial #124123) that lacked a guard on its point of operation. e. On or about 8/2/2017, at the model shop of the addressed worksite, an employee was exposed to a caught by hazard while working with a drill press (i.e. Clausing, Model 1634, Serial #124154) that lacked a guard on its point of operation. f. On or about 8/2/2017, at the model shop of the addressed worksite, an employee was exposed to a caught by hazard while working with a drill press (i.e. Clausing, Model 1676, Serial #125412) that lacked a guard on its point of operation. g. On or about 8/2/2017, at the model shop of the addressed worksite, an employee was exposed to a caught by hazard while working with a drill press (i.e. Clausing. Model 1655, Serial #125413) that lacked a guard on its point of operation. h. On or about 11/8/2017, at the machine shop of the addressed worksite, an employee was exposed to a caught by hazard while working with a drill press (i.e. Orbit Machine Tool, Model OR-1412F, Serial #4531) that lacked a guard on its point of operation.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2017-12-20
Current Penalty 2281.2
Initial Penalty 3802.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about 11/8/2017, at the machine shop of the addressed worksite, an employee was exposed to a struck by hazard while working with a drill press (i.e. Orbit Machine Tool, Model OR-1412F, Serial #4531) that was not anchored.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2017-12-20
Current Penalty 2586.0
Initial Penalty 4310.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: On or about 8/2/2017, at the machine shop of the above addressed jobsite, an employee was exposed to a struck by hazard while working with a bench grinder (i.e. Elephant, Model No. GA-150) that lacked a work rest on the left side and its right side work rest was placed 1-inch away from the wheel.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2017-12-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about 8/2/2017, at the machine shop of the above addressed jobsite, an employee was exposed to a struck by hazard while working with a bench grinder (i.e. Elephant, Model No. GA-150) that lacked tongue guards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100217 C03 I E
Issuance Date 2017-12-20
Current Penalty 3802.8
Initial Penalty 6338.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(c)(3)(i)(e): The point of operation device did not require application of both of the operator's hands to machine operating controls and locating such controls at such a safety distance from the point of operation that the slide completes the downward travel or stops before the operator can reach into the point of operation with his hands: On or about 8/2/2017, at the machine shop of the above addressed worksite, an employee was exposed to a caught by hazard while working with as mechanical power press (i.e. Minster, Serial Number 6-5377) equipped that completed a cycle by pressing only one control of a two hand control point of operation device.
Citation ID 02001
Citaton Type Other
Standard Cited 19100253 B04 III
Issuance Date 2017-12-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: On or about 8/2/2017, at the welding area of the above addressed jobsite, employees were exposed to a fire hazard while working close to an area were an oxygen gas and acetylene gas cylinders were stored in close proximity.
Citation ID 02002
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2017-12-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about 8/2/2017, at the machine shop of the above addressed jobsite, a fluorescent lamp mounted on a fixed location was energized with an extension cord, exposing employees to a fire hazard.
342517794 0418800 2017-08-02 1408 SW 8TH STREET, POMPANO BEACH, FL, 33069
Inspection Type Referral
Scope Complete
Safety/Health Health
Close Conference 2017-08-02
Emphasis L: HINOISE, N: CHROME6
Case Closed 2018-02-05

Related Activity

Type Referral
Activity Nr 1248204
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2017-12-19
Abatement Due Date 2018-01-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about August 2, 2017, at the above addressed jobsite, the employer did not establish a written respiratory program with procedures for employees required to wear half mask respirators when engaged in spraying operations during metal fabrication.
Citation ID 01002
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2017-12-19
Abatement Due Date 2018-02-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees' ability to use a respirator, before the employees were fit tested or required to use the respirator in the workplace: On or about August 2, 2017, at the above addressed jobsite, the employer did not provide medical evaluations to employees who are required to wear tight fitting half mask respirator when performing spray applications for metal fabrication operations.
Citation ID 01003
Citaton Type Other
Standard Cited 19100134 F02
Issuance Date 2017-12-19
Abatement Due Date 2018-02-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: On or about August 2, 2017 at the above addressed jobsite, the employer did not conduct fit testing for employees required to wear tight-fitting respirators, when performing spray applications during metal fabrication operations.
Citation ID 01004
Citaton Type Other
Standard Cited 19100134 K
Issuance Date 2017-12-19
Abatement Due Date 2018-02-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-23
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable, and effective annual training to employees who were required to use respirators. On or about August 2, 2017, at the above addressed jobsite, the employer did not ensure that employees who are required to wear respirators during metal fabrication operations, were provided with annual training on respiratory protection.
Citation ID 01005
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2017-12-19
Abatement Due Date 2018-01-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-23
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about August 2, 2017, at the above addressed jobsite, the employer did not develop a written hazard communication program for employees who use hazardous chemicals such as, but no limited to, xylene, methyl ethyl ketone, and methyl (n-amyl) ketone, while performing spray applications as part of metal fabrication operations.
Citation ID 01006
Citaton Type Other
Standard Cited 19101200 H03
Issuance Date 2017-12-19
Abatement Due Date 2018-01-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-23
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv) where topics of including, (i) Methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (ii) The physical and health hazards, as well as hazards not otherwise classified, of the chemicals in the work area; (iii) measures and procedures to protect employees from exposure to hazardous chemicals, (iv) sections of the hazard communication program were discussed: On or about August 2, 2017, at the above addressed jobsite, the employer did not develop a training program for employees who use hazardous chemicals such as, but no limited to, xylene, methyl (n-amyl) ketone, and butanone, while performing metal fabrication operations.
307299701 0418800 2004-07-08 1650 NW 66TH STREET, PLANTATION, FL, 33313
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2004-07-08
Emphasis N: AMPUTATE, S: AMPUTATIONS
Case Closed 2004-08-18

Date of last update: 01 Mar 2025