Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-25
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2015-07-20
|
Related Activity
Type |
Complaint |
Activity Nr |
977760 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1060045 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1060062 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2015-07-06 |
Current Penalty |
1260.0 |
Initial Penalty |
2100.0 |
Final Order |
2015-07-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a. On or about April 30, 2015, at the kitchen area of the above addressed worksite, an employee was exposed to a struck by hazard while working in close proximity to a cylinder which was not secured. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100036 G02 |
Issuance Date |
2015-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: a. At the kitchen area of the above addressed worksite, a passageway for a storage area was reduced to less than 16" wide, exposing employees to the risk of being trapped in the event of a fire. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-04-30
|
Emphasis |
N: SILICA
|
Case Closed |
2015-07-15
|
Related Activity
Type |
Complaint |
Activity Nr |
977760 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1059920 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1060076 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2015-07-02 |
Abatement Due Date |
2015-07-29 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about April 30, 2015 at the above addressed job site, employees performing dishwashing operation were not provided with safety glasses or face-shield when replacing corrosive material containers in dispensers, such as, but not limited, to Ecolab Ultra San, Ecolab Solid Power XL, Grease Cutter Plus and Ecotemp Ultra Klene for employees performing dishwashing operations exposing employees to severe chemical burns and serious eye damage. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2015-07-02 |
Current Penalty |
1785.0 |
Initial Penalty |
2975.0 |
Final Order |
2015-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about April 30, 2015 at the above addressed worksite, employer failed to provide suitable facilities for quick drenching or flushing of eyes and body for employees using corrosive chemicals, such as but not limited to Ecolab Ultra San, Ecolab Solid Power XL, Grease Cutter Plus and Ecotemp Ultra Klene for employees performing dishwashing operations exposing employees to severe chemical burns and serious eye damage. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2015-07-02 |
Abatement Due Date |
2015-07-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about April 30, 2015 at the above addressed job site, the employer did not develop or implement a written hazard communication program describing hazardous chemicals, such as, but not limited, to Ecolab Ultra San, Ecolab Solid Power XL, Grease Cutter Plus and Ecotemp Ultra Klene for employees performing dishwashing operations exposing employees to severe chemical burns and serious eye damage. |
|
|