Search icon

GATE TECH, INC. - Florida Company Profile

Company Details

Entity Name: GATE TECH, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GATE TECH, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 22 Mar 1996 (29 years ago)
Document Number: P96000025864
FEI/EIN Number 593369212

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1908 Wood Court, PLANT CITY, FL, 33563, US
Mail Address: 1908 Wood Court, PLANT CITY, FL, 33563, US
ZIP code: 33563
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PELHAM MICHAEL K President 1908 Wood Court, Plant City, FL, 33563
PELHAM KATHRYN V Secretary 1908 Wood Court, Plant City, FL, 33563
PELHAM KATHRYN V Treasurer 1908 Wood Court, Plant City, FL, 33563
PELHAM NATHAN J Vice President 1908 Wood Court, PLANT CITY, FL, 33563
Pelham Christopher J Vice President 1908 Wood Court, Plant City, FL, 33563
PELHAM MICHAEL Agent 1908 Wood Court, Plant City, FL, 33563

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2018-04-24 1908 Wood Court, Plant City, FL 33563 -
CHANGE OF PRINCIPAL ADDRESS 2016-04-15 1908 Wood Court, PLANT CITY, FL 33563 -
CHANGE OF MAILING ADDRESS 2016-04-15 1908 Wood Court, PLANT CITY, FL 33563 -

Documents

Name Date
ANNUAL REPORT 2024-02-12
ANNUAL REPORT 2023-02-17
ANNUAL REPORT 2022-01-24
ANNUAL REPORT 2021-04-08
ANNUAL REPORT 2020-03-17
ANNUAL REPORT 2019-04-25
ANNUAL REPORT 2018-04-24
ANNUAL REPORT 2017-04-10
ANNUAL REPORT 2016-04-15
ANNUAL REPORT 2015-04-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342918422 0420600 2018-02-01 1908 WOOD CT, PLANT CITY, FL, 33563
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2018-02-01
Case Closed 2018-04-13

Related Activity

Type Referral
Activity Nr 1302539
Health Yes
342839032 0420600 2017-12-19 1908 WOOD CT, PLANT CITY, FL, 33563
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-12-19
Emphasis L: FORKLIFT, N: DUSTEXPL
Case Closed 2018-05-15

Related Activity

Type Complaint
Activity Nr 1291267
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A02
Issuance Date 2018-02-27
Abatement Due Date 2018-03-23
Current Penalty 886.8
Initial Penalty 2217.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean condition. a) On or about 12/19/2017, powder coating dust occupied the floor surface area of the powder coating area/room due to extensive dust accumulation. The depth of accumulation was measured to be between 1/4 inch and 1/16 inch deep. The dust had a positive Kst value of 21.66 bar*m/s resulting in a fire and/or flash flame/deflagration hazard in the powder coating area/room.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100107 L03
Issuance Date 2018-02-27
Abatement Due Date 2018-03-30
Current Penalty 886.8
Initial Penalty 2217.0
Final Order 2018-03-23
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(l)(3): The applicable provisions of the Standard for Ovens and Furnaces, NFPA No. 86A-1969, were not met: a) On or about 12/19/2017, an oven used to cure powder coating was observed to have a safety sensor/switch bypassed with a pair of vice grips. This is in violation of 500-1(c) of NFPA 86A-1969. b) On or about 12/19/2017, An oven used to cure powder coating had been installed in-house. No drawings/plans for the oven were available and no approval had been sought before installation from an authority having jurisdiction as required in section 100-3 of NFPA 86A-1969.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100132 A
Issuance Date 2018-02-27
Abatement Due Date 2018-03-16
Current Penalty 886.8
Initial Penalty 2217.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) On or about 12/19/2017, a Baker forklift used routinely at the facility was not equipped with a seat belt. This condition exposed employees to potential crushing hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2018-02-27
Abatement Due Date 2018-03-23
Current Penalty 886.8
Initial Penalty 2217.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about 12/18/2017, a Baker sit-down propane forklift was operated on site. forklift operators had not been through training and evaluation as required by paragraph (l).
Citation ID 01005
Citaton Type Serious
Standard Cited 19100178 M09
Issuance Date 2018-02-27
Abatement Due Date 2018-03-16
Current Penalty 886.8
Initial Penalty 2217.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(m)(9): Industrial truck(s) were not fitted with overhead guard(s) as protection against falling objects: a) On or about 12/19/2017, a Baker Forklift used routinely at the establishment was not equipped with an overhead guard. The forklift moved material such as, but not limited to, fencing.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100178 Q01
Issuance Date 2018-02-27
Abatement Due Date 2018-03-16
Current Penalty 1108.8
Initial Penalty 2772.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: a) On or about 12/19/2017, a powered industrial truck used at the facility had multiple defects in that hydraulic cylinders were leaking and hold down restraints and support for it's propane cylinder were missing bolts and did not secure the propane tank.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100178 Q07
Issuance Date 2018-02-27
Abatement Due Date 2018-03-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) On or about 12/13/2017, a Baker forklift was observed to have a leaking hydraulic cylinder, a propane tank that was not secured, a missing seat belt, and no overhead guard. It was not being examined prior to use.