Search icon

BRIDGES EQUIPMENT & MAINTENANCE, INC. - Florida Company Profile

Headquarter

Company Details

Entity Name: BRIDGES EQUIPMENT & MAINTENANCE, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

BRIDGES EQUIPMENT & MAINTENANCE, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 Mar 1996 (29 years ago)
Date of dissolution: 27 Aug 2020 (5 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 27 Aug 2020 (5 years ago)
Document Number: P96000019950
FEI/EIN Number 650650656

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3530 E LAUREL RD, NOKOMIS, FL, 34275
Mail Address: 3530 E LAUREL RD, N. VENICE, FL, 34275, US
ZIP code: 34275
County: Sarasota
Place of Formation: FLORIDA

Links between entities

Type Company Name Company Number State
Headquarter of BRIDGES EQUIPMENT & MAINTENANCE, INC., MISSISSIPPI 954762 MISSISSIPPI

Key Officers & Management

Name Role Address
BRIDGES JOHN B President 3530 East Laurel Road, North Venice, FL, 34275
BRIDGES JOHN B Agent 3530 East Laurel Road, North Venice, FL, 34275

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2020-08-27 - -
REGISTERED AGENT ADDRESS CHANGED 2019-03-04 3530 East Laurel Road, North Venice, FL 34275 -
CHANGE OF MAILING ADDRESS 2018-02-09 3530 E LAUREL RD, NOKOMIS, FL 34275 -
REINSTATEMENT 2011-06-09 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2010-09-24 - -
REGISTERED AGENT NAME CHANGED 2003-05-12 BRIDGES, JOHN BSR -

Documents

Name Date
VOLUNTARY DISSOLUTION 2020-08-27
ANNUAL REPORT 2019-03-04
ANNUAL REPORT 2018-02-09
ANNUAL REPORT 2017-03-06
ANNUAL REPORT 2016-03-10
ANNUAL REPORT 2015-03-27
ANNUAL REPORT 2014-03-21
ANNUAL REPORT 2013-01-13
ANNUAL REPORT 2012-02-10
REINSTATEMENT 2011-06-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343564647 0418800 2018-10-29 12202 NW 25TH STREET, MIAMI, FL, 33182
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2018-10-29
Emphasis L: FALL
Case Closed 2020-01-22

Related Activity

Type Accident
Activity Nr 1399074
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261412 D03
Issuance Date 2019-04-25
Abatement Due Date 2019-05-22
Current Penalty 2386.8
Initial Penalty 3978.0
Final Order 2019-05-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1412(d)(3): The employer did not ensure the equipment was removed from service when the daily inspection revealed deficiencies in items (d)(1)(i) through (d)(1)(xiv) of this section: On or about October 29, 2018, at 1220 l NW 25th Street, Miami, Florida, 33182, a mobile crane with an inoperative safety computer (load weighing device and rated capacity indicator) and anti-two blocking device (operational aids), was not removed from service, therefore exposing an employee who was being elevated in the man-basket to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261412 F02
Issuance Date 2019-04-25
Abatement Due Date 2019-05-22
Current Penalty 2386.8
Initial Penalty 3978.0
Final Order 2019-05-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1412(f)(2): The equipment was not inspected by a qualified person at least every 12 months in accordance with paragraphs (f)(2)(i) - (xxi) of this section: On or about October 29, 2018, at 1220 I NW 25th Street, Miami, Florida, 33I 82, the employer failed to ensure that annual comprehensive inspections were conducted by a qualified person, therefore exposing the employee in the man-basket to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261431 K10 I
Issuance Date 2019-04-25
Abatement Due Date 2019-05-22
Current Penalty 10608.0
Initial Penalty 13260.0
Final Order 2019-05-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1431(k)(10)(i): Except over water, employees occupying the personnel platform must be provided and use a personal fall arrest system. The system must be attached to a structural member within the personnel platform. When working over or near water, the requirements of � 1926.106 apply: On or about October 29, 2018, at 12201 NW 25th Street, Miami, Florida, 33182, the employer failed to ensure that an employee who was raised and lowered in a man-basket, used a personal fall arrest system; therefore exposing the employee to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261431 K02 II
Issuance Date 2019-04-25
Abatement Due Date 2019-05-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-14
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1431(k)(2)(ii): The employer did not ensure that each employee was not standing, sitting on or working from the top or intermediate rail or toe board, or use any others means/device to raise their working height: On or about October 29, 2018, at 12201 NW 25th Street, Miami, Florida, 33182, the employer permitted an employee to sit on the guardrail of a man-basket during the raising, lowering, and horizontal movement of the crane, therefore exposing the employee to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Citation ID 02001
Citaton Type Other
Standard Cited 19261417 C01
Issuance Date 2019-04-25
Abatement Due Date 2019-05-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-14
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, were not readily available in the cab at all times for use by the operator: On or about October 29, 2018, at 12201 NW 25th Street, Miami, Florida, 33182, the employer failed to ensure that procedures, applicable to the operation of the equipment, and the operator's manual were readily available in the crane cab at all times. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.