Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-10-29
|
Emphasis |
L: FALL
|
Case Closed |
2020-01-22
|
Related Activity
Type |
Accident |
Activity Nr |
1399074 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261412 D03 |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-22 |
Current Penalty |
2386.8 |
Initial Penalty |
3978.0 |
Final Order |
2019-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1412(d)(3): The employer did not ensure the equipment was removed from service when the daily inspection revealed deficiencies in items (d)(1)(i) through (d)(1)(xiv) of this section: On or about October 29, 2018, at 1220 l NW 25th Street, Miami, Florida, 33182, a mobile crane with an inoperative safety computer (load weighing device and rated capacity indicator) and anti-two blocking device (operational aids), was not removed from service, therefore exposing an employee who was being elevated in the man-basket to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261412 F02 |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-22 |
Current Penalty |
2386.8 |
Initial Penalty |
3978.0 |
Final Order |
2019-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1412(f)(2): The equipment was not inspected by a qualified person at least every 12 months in accordance with paragraphs (f)(2)(i) - (xxi) of this section: On or about October 29, 2018, at 1220 I NW 25th Street, Miami, Florida, 33I 82, the employer failed to ensure that annual comprehensive inspections were conducted by a qualified person, therefore exposing the employee in the man-basket to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261431 K10 I |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-22 |
Current Penalty |
10608.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1431(k)(10)(i): Except over water, employees occupying the personnel platform must be provided and use a personal fall arrest system. The system must be attached to a structural member within the personnel platform. When working over or near water, the requirements of � 1926.106 apply: On or about October 29, 2018, at 12201 NW 25th Street, Miami, Florida, 33182, the employer failed to ensure that an employee who was raised and lowered in a man-basket, used a personal fall arrest system; therefore exposing the employee to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261431 K02 II |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1431(k)(2)(ii): The employer did not ensure that each employee was not standing, sitting on or working from the top or intermediate rail or toe board, or use any others means/device to raise their working height: On or about October 29, 2018, at 12201 NW 25th Street, Miami, Florida, 33182, the employer permitted an employee to sit on the guardrail of a man-basket during the raising, lowering, and horizontal movement of the crane, therefore exposing the employee to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19261417 C01 |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, were not readily available in the cab at all times for use by the operator: On or about October 29, 2018, at 12201 NW 25th Street, Miami, Florida, 33182, the employer failed to ensure that procedures, applicable to the operation of the equipment, and the operator's manual were readily available in the crane cab at all times. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|