Entity Name: | S.T.E. INC. OF NEW PORT RICHEY |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
S.T.E. INC. OF NEW PORT RICHEY is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 11 Jan 1996 (29 years ago) |
Date of dissolution: | 23 Sep 2022 (3 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 23 Sep 2022 (3 years ago) |
Document Number: | P96000004371 |
FEI/EIN Number |
593198005
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 8635 ARCOLA AVE., HUDSON, FL, 34667 |
Mail Address: | 27036 Ernest Lee Rd, Brooksville, FL, 34602, US |
ZIP code: | 34667 |
County: | Pasco |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
SCHALMO JOHN | President | 27036 Ernest Lee Rd, Brooksville, FL, 34602 |
SCHALMO JOHN | Agent | 9050 BULLRUSH CT, NEW PORT RICHEY, FL, 34654 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2022-09-23 | - | - |
CHANGE OF MAILING ADDRESS | 2021-04-06 | 8635 ARCOLA AVE., HUDSON, FL 34667 | - |
CHANGE OF PRINCIPAL ADDRESS | 2007-04-19 | 8635 ARCOLA AVE., HUDSON, FL 34667 | - |
REINSTATEMENT | 1999-12-28 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 1997-09-26 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2021-04-06 |
ANNUAL REPORT | 2020-07-19 |
ANNUAL REPORT | 2019-02-20 |
ANNUAL REPORT | 2018-03-26 |
ANNUAL REPORT | 2017-03-27 |
ANNUAL REPORT | 2016-03-29 |
ANNUAL REPORT | 2015-04-28 |
ANNUAL REPORT | 2014-07-25 |
ANNUAL REPORT | 2013-07-31 |
ANNUAL REPORT | 2012-04-30 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339365421 | 0420600 | 2013-08-12 | 425 E BRANDON BLVD., BRANDON, FL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 893556 |
Safety | Yes |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2013-03-04 |
Emphasis | N: TRENCH, P: TRENCH |
Case Closed | 2013-09-10 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2013-04-11 |
Abatement Due Date | 2013-04-30 |
Current Penalty | 2400.0 |
Initial Penalty | 2400.0 |
Final Order | 2013-05-22 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) For the S.T.E., Inc. work site at 425 E. Brandon Blvd., Brandon, FL 33508, as observed on or about 03/04/2013, Employees were exposed to cave-in hazards while working in an unprotected excavation. Employees were not aware of how deep you can dig before excavation safety systems are needed and had not received any excavation safety training. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2013-04-11 |
Abatement Due Date | 2013-04-17 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-05-22 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) For the S.T.E., Inc. work site at 425 E. Brandon Blvd., Brandon, FL 33508, as observed on or about 03/04/2013, The spoil pile on the west and east end of the excavation was placed right next to the excavation. The spoils were multiple feet high, consisted of sandy soil, and posed a hazard of falling into the excavation and producing extra loads on the bank walls of the excavation, promoting cave-in. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2013-04-11 |
Abatement Due Date | 2013-04-17 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-05-22 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the excavation was sloped at an angle steeper than one and one-half horizontal to one vertical (34 degrees measured from the horizontal): a) For the S.T.E., Inc. work site at 425 E. Brandon Blvd., Brandon, FL 33508, as observed on or about 03/04/2013, employees were working in an excavation that was measured to be between 6 ft. and 7.14 ft. deep at the location employees were working. No cave in protection was being used and the excavation side walls were measured to be 56 degrees, 51 degrees, and 45.6 degrees respectively. The soil was analyzed to be type C and employees working in the excavation were exposed to cave-in hazards. |