Entity Name: | JACK'S COMPLETE TREE SERVICE, INC. |
Jurisdiction: | FLORIDA |
Filing Type: | Florida Profit Corporation |
Status: | Active |
Date Filed: | 08 Nov 1995 (29 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 20 Jan 2011 (14 years ago) |
Document Number: | P95000085791 |
FEI/EIN Number | 65-0631485 |
Address: | 6385 5TH STREET, VERO BEACH, FL 32968 |
Mail Address: | 6385 5TH STREET, VERO BEACH, FL 32968 |
ZIP code: | 32968 |
County: | Indian River |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
RESCHAK, JOHN W | Agent | 6385 5TH STREET, VERO BEACH, FL 32968 |
Name | Role | Address |
---|---|---|
RESCHAK, JOHN W | Vice President | 6385 5TH STREET, VERO BEACH, FL 32968 |
RESCHAK, CYNTHIA A | Vice President | 6385 5TH STREET, VERO BEACH, FL 32968 |
Name | Role | Address |
---|---|---|
RESCHAK, JOHN W | Treasurer | 6385 5TH STREET, VERO BEACH, FL 32968 |
Name | Role | Address |
---|---|---|
RESCHAK, JOHN W | Director | 6385 5TH STREET, VERO BEACH, FL 32968 |
RESCHAK, CYNTHIA A | Director | 6385 5TH STREET, VERO BEACH, FL 32968 |
RESCHAK, MICHAEL B | Director | 6715 3rd Pl SW, VERO BEACH, FL 32968 |
Name | Role | Address |
---|---|---|
RESCHAK, CYNTHIA A | Secretary | 6385 5TH STREET, VERO BEACH, FL 32968 |
Name | Role | Address |
---|---|---|
RESCHAK, MICHAEL B | President | 6715 3rd Pl SW, VERO BEACH, FL 32968 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2025-05-01 | 6385 5TH STREET, VERO BEACH, FL 32968 | No data |
CHANGE OF MAILING ADDRESS | 2025-05-01 | 6385 5TH STREET, VERO BEACH, FL 32968 | No data |
REINSTATEMENT | 2011-01-20 | No data | No data |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2010-09-24 | No data | No data |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-08 |
ANNUAL REPORT | 2024-01-31 |
ANNUAL REPORT | 2023-01-25 |
ANNUAL REPORT | 2022-01-13 |
ANNUAL REPORT | 2021-01-11 |
ANNUAL REPORT | 2020-01-17 |
ANNUAL REPORT | 2019-01-18 |
ANNUAL REPORT | 2018-01-11 |
ANNUAL REPORT | 2017-01-03 |
ANNUAL REPORT | 2016-01-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346522923 | 0418800 | 2023-02-23 | 15 SEA COURT, VERO BEACH, FL, 32965 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1609493 |
Safety | Yes |
Inspection Type | Fat/Cat |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2022-07-28 |
Emphasis | L: LANDSCPE |
Case Closed | 2023-11-13 |
Related Activity
Type | Accident |
Activity Nr | 1922114 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100333 C03 I A 1 |
Issuance Date | 2023-01-06 |
Abatement Due Date | 2023-02-02 |
Current Penalty | 10151.4 |
Initial Penalty | 14502.0 |
Final Order | 2023-01-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact came closer than 10 ft. (305 cm) to any unguarded, energized overhead line: On or about July 7, 2022, at 2430 18th Ave. Vero Beach FL, employees were exposed to electrical hazards from a 7.6 kV overhead power line while engaged in tree trimming work approximately 7-feet away from the power line. |
Citation ID | 02001A |
Citaton Type | Other |
Standard Cited | 19040039 A01 |
Issuance Date | 2023-01-06 |
Current Penalty | 2486.4 |
Initial Penalty | 4144.0 |
Final Order | 2023-01-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident On or about July 17, 2022, at 2430 18th Ave. Vero Beach FL, the employer did not report to OSHA within 8-hours a work-related incident that resulted in a death of an employee. |
Citation ID | 02001B |
Citaton Type | Other |
Standard Cited | 19040039 A02 |
Issuance Date | 2023-01-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-01-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. On or about July 7, 2022, at 2430 18th Ave. Vero Beach FL, the employer did not report to OSHA within 24-hours a work-related incident that resulted in the hospitalization of an employee. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2023-01-06 |
Abatement Due Date | 2023-02-02 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-01-18 |
Nr Instances | 1 |
Nr Exposed | 13 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about July 7, 2022, at 2430 18th Ave. Vero Beach FL, employer had not developed or implemented a written hazard communication program for employees exposed to hazardous chemicals such as, gasoline and oil used by employees on equipment while conducting landscaping activities. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19101200 G01 |
Issuance Date | 2023-01-06 |
Abatement Due Date | 2023-02-02 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-01-18 |
Nr Instances | 1 |
Nr Exposed | 13 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: On or about July 7, 2022, jobsite located at 2430 18th Ave. Vero Beach FL, the employer did not have safety data sheets in the workplace for hazardous chemicals, such as but not limited to gasoline and oil used by employees for equipment while conducting landscaping activities. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2016-06-03 |
Emphasis | L: LANDSCPE, P: LANDSCPE |
Case Closed | 2016-08-17 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100067 C02 V |
Issuance Date | 2016-07-19 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2016-08-08 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.67(c)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift: On or about June 3, 2016, at the above addressed worksite, an employee was exposed to a fall hazard of approximately 18 to 20 feet when performing tree work from the bucket of a truck mounted aerial lift while not wearing a harness with a lanyard or safety belt with a positioning device attached to the boom or basket of that lift. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100133 A01 |
Issuance Date | 2016-07-19 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2016-08-08 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about June 3, 2016, at the above addressed site, an employee was exposed to potential eye injury from flying particles when performing tree work with a chainsaw while not wearing eye protection equipment. |
Date of last update: 02 Feb 2025
Sources: Florida Department of State