Search icon

DUFFIELD ALUMINUM, INC. - Florida Company Profile

Company Details

Entity Name: DUFFIELD ALUMINUM, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

DUFFIELD ALUMINUM, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 01 Sep 1995 (30 years ago)
Last Event: AMENDMENT
Event Date Filed: 17 Feb 1996 (29 years ago)
Document Number: P95000068570
FEI/EIN Number 593327980

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL, 32609, US
Mail Address: 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL, 32609, US
ZIP code: 32609
County: Alachua
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
DUFFIELD WILLIAM P President 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL, 32609
DUFFIELD WILLIAM P Secretary 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL, 32609
DUFFIELD WILLIAM P Treasurer 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL, 32609
Duffield Nancy D Chief Financial Officer 4566 NW 5TH BLVD., GAINESVILLE, FL, 32609
York Blake Vice President 4566 NW 5TH BLVD., GAINESVILLE, FL, 32609
DUFFIELD WILLIAM P Agent 4566 NW 5TH BLVD., GAINESVILLE, FL, 32609

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G07190900378 DUFFIELD HOME IMPROVEMENTS ACTIVE 2007-07-09 2027-12-31 - 4566 N.W. 5TH BLVD., SUITE I, GAINESVILLE, FL, 32609

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2015-02-24 DUFFIELD, WILLIAM P -
CHANGE OF PRINCIPAL ADDRESS 2012-04-26 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL 32609 -
CHANGE OF MAILING ADDRESS 2012-04-26 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL 32609 -
REGISTERED AGENT ADDRESS CHANGED 2012-04-26 4566 NW 5TH BLVD., STE I, GAINESVILLE, FL 32609 -
AMENDMENT 1996-02-16 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J12000080211 LAPSED 2011-CC-004171 ALACHUA COUNTY COURT 2012-01-17 2017-02-07 $13,428.17 YELLOW BOOK, INC. FKA YELLOW BOOK SALES AND DISTRIBUTIO, C/O SPRECHMAN & ASSOCIATES, P.A., 2775 SUNNY ISLES BLVD #100, NORTH MIAMI BEACH, FL 33160
J11000824925 LAPSED 2011-CA-2082 8TH CIRCUIT ALACHUA COUNTY 2011-10-17 2016-12-20 $152,453.27 SUNTRUST BANK, 303 PEACHTREE STREET NE, 3600, ATLANTA GA 30308
J07900015066 LAPSED 07-006222 COCE CTY CRT IN BROWARD CTY FL 2007-09-12 2012-10-01 $18655.63 R&K SUPPLY & CONTRACTING, INC, 5603 N. STATE RD 7, FORT LAUDERDALE, FL 33319
J07900015065 LAPSED 07-006222 COCE CTY CRT FOR BROWARD CTY FL 2007-09-12 2012-10-01 $18655.63 R&K SUPPLY & CONTRACTING, INC., 5603 N. STATE RD 7, FORT LAUDERDALE, FL 33319
J07900012942 LAPSED 07-CC-1806 LAKE CTY CIRCUIT CRT TAVARES 2007-07-23 2012-08-27 $5139.44 METALS USA BUILDING PRODUCTS, L.P., 7815 AMERICAN WAY, GROVELAND, FL 34736

Documents

Name Date
ANNUAL REPORT 2024-01-15
ANNUAL REPORT 2023-02-20
ANNUAL REPORT 2022-03-14
ANNUAL REPORT 2021-02-05
ANNUAL REPORT 2020-02-04
ANNUAL REPORT 2019-04-08
ANNUAL REPORT 2018-01-15
ANNUAL REPORT 2017-01-11
ANNUAL REPORT 2016-03-29
ANNUAL REPORT 2015-02-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344079959 0419700 2019-06-12 9497 SW 67TH LN, GAINESVILLE, FL, 32608
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-06-12
Emphasis L: FALL, P: FALL
Case Closed 2022-11-23

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2019-07-01
Current Penalty 8752.0
Initial Penalty 8752.0
Contest Date 2019-07-25
Final Order 2022-02-14
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a. On or about June 12, 2019, on the roof, two roofing employees were not provided eye protection when operating a pneumatic nail gun, exposing them to an eye injury hazard. Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1078605, Serious citation number 1, item number 2and was affirmed as a final order on September 14, 2015, with respect to a workplace located at 5542 NW 43rd St Gainesville, Florida.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2019-07-01
Current Penalty 21248.0
Initial Penalty 43759.0
Contest Date 2019-07-25
Final Order 2022-02-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about June 12, 2019, on the 6:12 pitch roof, three roofing employees installing shingles were exposed to a 9-feet fall hazard in that they were not protected by a fall protection system. Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1193835, Repeat serious citation number 1, item number 1 and was affirmed as a final order on December 21, 2017, with respect to a workplace located at 3147 SW 106 St, Gainesville, Florida. Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSHA inspection number 1078605, Repeat serious citation number 2, item number 1 and was affirmed as a final order on September 14, 2015, with respect to a workplace located at 5542 NW 43rd St Gainesville, Florida.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2019-07-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-07-25
Final Order 2022-02-14
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): A training program was not provided to each employee who might be exposed to fall hazards, to enable that employee to recognize the hazards of falling, and be trained in the procedures to be followed to minimize these hazards: a. On or about June 12, 2019, the employer had not provided adequate fall protection training to employees for fastening anchor plates used as part of personal fall protection systems.
Citation ID 02002A
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2019-07-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-07-25
Final Order 2022-02-14
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about June 12, 2019, above the side door entrance, three employees used the roof access ladder that was extended 33-inches of the required 36 inches above the roof eave edge.
Citation ID 02002B
Citaton Type Other
Standard Cited 19261053 B05 I
Issuance Date 2019-07-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-07-25
Final Order 2022-02-14
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about June 12, 2019, above the side door entrance, the roof access ladder was placed at 63-degrees, 12-degrees shallower than required by the standard.
342316437 0419700 2017-05-10 2968 SW 106TH ST LOT 11, GAINESVILLE, FL, 32608
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-05-10
Emphasis L: FALL, P: FALL
Case Closed 2017-09-06

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260503 A01
Issuance Date 2017-08-03
Abatement Due Date 2017-08-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-29
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a. On or about May 10, 2017, at 2969 SW 106th Street in Gainesville Florida, employees installing drip edge trim metal on a 4:12 pitch roof with an eave height of 11 feet without fall protection, had not been trained to install and utilize fall protection equipment to minimize fall hazards.
341938355 0419700 2016-11-29 3147 SW 106 STREET, GAINESVILLE, FL, 32601
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-11-29
Emphasis L: FALL, P: FALL
Case Closed 2018-06-13

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-12-20
Current Penalty 2500.0
Initial Penalty 10974.0
Contest Date 2017-01-18
Final Order 2017-12-21
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 29, 2016, on a 6:12 pitch roof, three employees performing roofing operations were not protected from a 12-foot 4-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternate fall protection. The Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSHA inspection number 1078605, citation number 1, item number 1 and was affirmed as a final order on September 14, 2016, with respect to a workplace located at 5542 NW 43rd Street, Gainesville, Florida 32601.
341454148 0419700 2016-05-04 23075 NW 179TH PL., HIGH SPRINGS, FL, 32643
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-05-05
Emphasis L: FALL, P: FALL
Case Closed 2017-05-31

Related Activity

Type Referral
Activity Nr 1087004
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2016-07-22
Current Penalty 1636.5
Initial Penalty 3273.0
Contest Date 2016-08-22
Final Order 2017-04-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about April 29, 2016, on the northeast side of the building, an employee performing roofing work suffered serious injuries when he fell from a 6 feet fiberglass step ladder while working on the top step.
341208601 0419700 2016-01-27 1111 SW 16TH AVE., GAINESVILLE, FL, 32601
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-01-27
Emphasis L: FALL
Case Closed 2016-06-13

Related Activity

Type Referral
Activity Nr 1055623
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 D16
Issuance Date 2016-03-17
Abatement Due Date 2016-05-03
Current Penalty 5000.0
Initial Penalty 14000.0
Final Order 2016-04-11
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16): Personal fall arrest systems, when stopping a fall, shall:
340786052 0419700 2015-07-16 5542 NW 43RD STREET, GAINESVILLE, FL, 32653
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2015-07-16
Emphasis L: FALL
Case Closed 2015-11-25

Related Activity

Type Complaint
Activity Nr 892227
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2015-08-17
Abatement Due Date 2015-08-25
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets: a. On or about July 16, 2015, the employee picking up debris on the ground underneath other employees working on the roof was not wearing a hard hat, being exposed to head injuries.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-08-17
Abatement Due Date 2015-08-25
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about July 16, 2015, employees using nail guns were not provided safety glasses, being exposed to eye injuries.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-08-17
Abatement Due Date 2015-08-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: a. On or about July 16, 2015, front of the building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided. b. On or about July 16, 2015, left side of the building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided. c. On or about July 16, 2015, right side of building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B11
Issuance Date 2015-08-17
Current Penalty 9800.0
Initial Penalty 9800.0
Final Order 2015-09-14
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about July 16, 2015, roof area, employees installing roofing shingles on a 7:12 pitch roof were not protected from falling up to 12 feet 4 inches by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method. Duffield Aluminum Inc. dba Duffield Home Improvements was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 315478008, citation number 01, item number 002 and was affirmed as a final order on August 15, 2011, with respect to a workplace located at 3641 NW 13th Street, Gainesville, Florida 32609.
339010969 0419700 2013-04-16 4566 NW 5TH BOULEVARD, GAINESVILLE, FL, 32609
Inspection Type Complaint
Scope NoInspection
Safety/Health Safety
Close Conference 2013-04-16
Case Closed 2013-04-18

Related Activity

Type Complaint
Activity Nr 813536
Safety Yes
18008474 0419700 2001-06-18 13840 W. NEWBERRY RD., JONESVILLE, FL, 32669
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2001-07-10
Emphasis S: CONSTRUCTION, L: FLCARE
Case Closed 2001-09-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2001-07-17
Abatement Due Date 2001-07-20
Current Penalty 375.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 2
Gravity 03
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 B02
Issuance Date 2001-07-17
Abatement Due Date 2001-07-20
Current Penalty 375.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 2
Gravity 03