344079959
|
0419700
|
2019-06-12
|
9497 SW 67TH LN, GAINESVILLE, FL, 32608
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-06-12
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2022-11-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260102 A01 |
Issuance Date |
2019-07-01 |
Current Penalty |
8752.0 |
Initial Penalty |
8752.0 |
Contest Date |
2019-07-25 |
Final Order |
2022-02-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a. On or about June 12, 2019, on the roof, two roofing employees were not provided eye protection when operating a pneumatic nail gun, exposing them to an eye injury hazard. Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1078605, Serious citation number 1, item number 2and was affirmed as a final order on September 14, 2015, with respect to a workplace located at 5542 NW 43rd St Gainesville, Florida. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-07-01 |
Current Penalty |
21248.0 |
Initial Penalty |
43759.0 |
Contest Date |
2019-07-25 |
Final Order |
2022-02-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about June 12, 2019, on the 6:12 pitch roof, three roofing employees installing shingles were exposed to a 9-feet fall hazard in that they were not protected by a fall protection system. Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1193835, Repeat serious citation number 1, item number 1 and was affirmed as a final order on December 21, 2017, with respect to a workplace located at 3147 SW 106 St, Gainesville, Florida. Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSHA inspection number 1078605, Repeat serious citation number 2, item number 1 and was affirmed as a final order on September 14, 2015, with respect to a workplace located at 5542 NW 43rd St Gainesville, Florida. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 A01 |
Issuance Date |
2019-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-07-25 |
Final Order |
2022-02-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): A training program was not provided to each employee who might be exposed to fall hazards, to enable that employee to recognize the hazards of falling, and be trained in the procedures to be followed to minimize these hazards: a. On or about June 12, 2019, the employer had not provided adequate fall protection training to employees for fastening anchor plates used as part of personal fall protection systems. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19261053 B01 |
Issuance Date |
2019-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-07-25 |
Final Order |
2022-02-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about June 12, 2019, above the side door entrance, three employees used the roof access ladder that was extended 33-inches of the required 36 inches above the roof eave edge. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19261053 B05 I |
Issuance Date |
2019-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-07-25 |
Final Order |
2022-02-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about June 12, 2019, above the side door entrance, the roof access ladder was placed at 63-degrees, 12-degrees shallower than required by the standard. |
|
|
342316437
|
0419700
|
2017-05-10
|
2968 SW 106TH ST LOT 11, GAINESVILLE, FL, 32608
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-05-10
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-09-06
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260503 A01 |
Issuance Date |
2017-08-03 |
Abatement Due Date |
2017-08-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-08-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a. On or about May 10, 2017, at 2969 SW 106th Street in Gainesville Florida, employees installing drip edge trim metal on a 4:12 pitch roof with an eave height of 11 feet without fall protection, had not been trained to install and utilize fall protection equipment to minimize fall hazards. |
|
|
341938355
|
0419700
|
2016-11-29
|
3147 SW 106 STREET, GAINESVILLE, FL, 32601
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-11-29
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-06-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-12-20 |
Current Penalty |
2500.0 |
Initial Penalty |
10974.0 |
Contest Date |
2017-01-18 |
Final Order |
2017-12-21 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about November 29, 2016, on a 6:12 pitch roof, three employees performing roofing operations were not protected from a 12-foot 4-inch fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternate fall protection. The Duffield Aluminum, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSHA inspection number 1078605, citation number 1, item number 1 and was affirmed as a final order on September 14, 2016, with respect to a workplace located at 5542 NW 43rd Street, Gainesville, Florida 32601. |
|
|
341454148
|
0419700
|
2016-05-04
|
23075 NW 179TH PL., HIGH SPRINGS, FL, 32643
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-05-05
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-05-31
|
Related Activity
Type |
Referral |
Activity Nr |
1087004 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2016-07-22 |
Current Penalty |
1636.5 |
Initial Penalty |
3273.0 |
Contest Date |
2016-08-22 |
Final Order |
2017-04-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about April 29, 2016, on the northeast side of the building, an employee performing roofing work suffered serious injuries when he fell from a 6 feet fiberglass step ladder while working on the top step. |
|
|
341208601
|
0419700
|
2016-01-27
|
1111 SW 16TH AVE., GAINESVILLE, FL, 32601
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-01-27
|
Emphasis |
L: FALL
|
Case Closed |
2016-06-13
|
Related Activity
Type |
Referral |
Activity Nr |
1055623 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 |
Issuance Date |
2016-03-17 |
Abatement Due Date |
2016-05-03 |
Current Penalty |
5000.0 |
Initial Penalty |
14000.0 |
Final Order |
2016-04-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16): Personal fall arrest systems, when stopping a fall, shall: |
|
|
340786052
|
0419700
|
2015-07-16
|
5542 NW 43RD STREET, GAINESVILLE, FL, 32653
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-07-16
|
Emphasis |
L: FALL
|
Case Closed |
2015-11-25
|
Related Activity
Type |
Complaint |
Activity Nr |
892227 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2015-08-17 |
Abatement Due Date |
2015-08-25 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets: a. On or about July 16, 2015, the employee picking up debris on the ground underneath other employees working on the roof was not wearing a hard hat, being exposed to head injuries. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2015-08-17 |
Abatement Due Date |
2015-08-25 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about July 16, 2015, employees using nail guns were not provided safety glasses, being exposed to eye injuries. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2015-08-17 |
Abatement Due Date |
2015-08-25 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: a. On or about July 16, 2015, front of the building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided. b. On or about July 16, 2015, left side of the building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided. c. On or about July 16, 2015, right side of building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B11 |
Issuance Date |
2015-08-17 |
Current Penalty |
9800.0 |
Initial Penalty |
9800.0 |
Final Order |
2015-09-14 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about July 16, 2015, roof area, employees installing roofing shingles on a 7:12 pitch roof were not protected from falling up to 12 feet 4 inches by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method. Duffield Aluminum Inc. dba Duffield Home Improvements was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 315478008, citation number 01, item number 002 and was affirmed as a final order on August 15, 2011, with respect to a workplace located at 3641 NW 13th Street, Gainesville, Florida 32609. |
|
|
339010969
|
0419700
|
2013-04-16
|
4566 NW 5TH BOULEVARD, GAINESVILLE, FL, 32609
|
|
Inspection Type |
Complaint
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2013-04-16
|
Case Closed |
2013-04-18
|
Related Activity
Type |
Complaint |
Activity Nr |
813536 |
Safety |
Yes |
|
|
18008474
|
0419700
|
2001-06-18
|
13840 W. NEWBERRY RD., JONESVILLE, FL, 32669
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2001-07-10
|
Emphasis |
S: CONSTRUCTION, L: FLCARE
|
Case Closed |
2001-09-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2001-07-17 |
Abatement Due Date |
2001-07-20 |
Current Penalty |
375.0 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260405 B02 |
Issuance Date |
2001-07-17 |
Abatement Due Date |
2001-07-20 |
Current Penalty |
375.0 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
|