Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-03-28
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2015-03-10
|
Related Activity
Type |
Referral |
Activity Nr |
871533 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-05-15 |
Current Penalty |
675.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Throughout Plant The employer did not establish and implement a written energy control program, on or about, 02/13/14. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-06-16 |
Current Penalty |
825.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-04-14 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by an inadequately guarded power press and unguarded unsed portion of a press brake. a) Door Department - Zeh & Hannemann 30 Ton Full Revolution Power Press - The existing fixed barrier guard did not enclose the top and side openings allowing for entry into the point of operation, on or about, 02/13/14. b) Spot Welding Area - Niagara 30 Ton Full Revolution Power Press - The existing fixed barrier guard did not enclose the top and side openings allowing for entry into the point of operation, on or about, 02/13/14. c) Press Brake Department - Cincinnati Press Brakes 250 Tons (2) Unguarded used portions of press dies, on or about, 02/13/14. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-06-16 |
Current Penalty |
825.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-04-14 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Metal Stud Area - Verson All Steel Press Brake - 45 Ton - Serial # 11536-2062-A Unguarded point of operation, on or about, 02/13/14. b) Press Brake Department - Cincinnati Press Brakes (2) 250 Tons - Unguarded point of operations, on or about, 02/13/14. c) Door Department - Lors Machinery Inc. Spot Welder - Model # 140 AR-OV - Serial # 100-6811 - Unguarded point of operation, on or about, 02/13/14. d) Spotwelding Area - Lors Spot Welder - Serial # 1955864 - Model # 418 Unguarded point of operation, on or about, 02/13/14. e) Shear Area - Accurshear Shear - Model# 613510 - Serial # 3401 - Inadequately guarded point of operation and an unguarded point of operation behind the shear, on or about, 02/13/14. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100219 B01 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-05-15 |
Current Penalty |
675.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-04-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a) a) Door Department - Zeh & Hannemann Co. 20 Ton Full Revolution Power Press Inadequately guarded flywheel on inside face of machine, on or about, 02/13/14. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100217 B04 II |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-05-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(b)(4)(ii): Mechanical power press(es) using full revolution clutches were not provided with a pad with a nonslip contact area firmly attached to the pedal: a) Spotwelding Area - Niagara Full Revolution Power Press - 30 Tons The foot pedal was missing a non-slip pad, on or about, 02/13/14. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100217 B04 III |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-05-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(b)(4)(iii): Pedal return spring(s) of pedal(s) used on mechanical power press(es) using full revolution clutches were not of the compression type, operating on a rod or guided within a hole or tube, or designed to prevent interleaving of sspring coils in the event of breakage: a) Spotwelding Area - Niagara Full Revolution Power Press - 30 Tons - The pedal spring was not operating on a rod or guided within a hole or tube and was attached to the press's single stroke mechanism via a string, on or about, 02/13/14. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100303 B01 |
Issuance Date |
2014-03-31 |
Abatement Due Date |
2014-04-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-04-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Door Department - Zeh & Hannemann Co. 20 Ton Full Revolution Power Press The power powering the press's foot pedal was torn from the grommet allowing for exposed live insulated conductors, on or about, 02/13/14. |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-02-06
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, N: ISOCYAN8, P: ISOCYAN8
|
Case Closed |
2014-07-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100038 B |
Issuance Date |
2014-04-21 |
Abatement Due Date |
2014-05-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-15 |
Nr Instances |
1 |
Nr Exposed |
11 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: (a) At the site, employees were exposed to hazards, such as but not limited to, smoke inhalation, trips, slips or falls, in that, the employer did not have a written emergency action plan. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100134 A02 |
Issuance Date |
2014-04-21 |
Abatement Due Date |
2014-05-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(a)(2): The employer did not establish and maintain a respiratory protection program which included the requirements outlined in 29 CFR 1910.134(c): (a)At the site, where chemical products such as DegaBond 55 adhesive were used and employees were required to wear respirators, there was no respirator program exposing employees to an inhalation hazard. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-04-21 |
Abatement Due Date |
2014-05-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a)At the site, where chemicals products such as DegaBond 55 adhesive were used, there was no hazard communication program exposing employees to an inhalation hazard. |
|
|