Search icon

FIRST CITY ROOFING, INC. - Florida Company Profile

Company Details

Entity Name: FIRST CITY ROOFING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FIRST CITY ROOFING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 05 May 1995 (30 years ago)
Date of dissolution: 23 Aug 1996 (29 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Aug 1996 (29 years ago)
Document Number: P95000036548
Address: 1591 N. WHITNEY ST., ST. AUGUSTINE, FL, 32095
Mail Address: 1591 N. WHITNEY ST., ST. AUGUSTINE, FL, 32095
ZIP code: 32095
County: St. Johns
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
LUKEHART DOUGLAS E Director 1591 N. WHITNEY ST., ST. AUGUSTINE, FL, 32095
LUKEHART DOUGLAS E Agent 237 CERVANTES AVE., ST. AUGUSTINE, FL, 32095

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 1996-08-23 - -

Documents

Name Date
DOCUMENTS PRIOR TO 1997 1995-05-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341862134 0419700 2016-10-25 7 B STREET, SAINT AUGUSTINE, FL, 32080
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-10-25
Emphasis L: FALL, P: FALL
Case Closed 2019-01-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-11-02
Current Penalty 2805.5
Initial Penalty 3741.0
Final Order 2016-11-29
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 25, 2016, on a 3:12 pitch roof, employees performing re-roofing operations, were not protected from a 16 foot fall hazard by use of a guardrail system, safety net system, personal fall arrest system or any alternative fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-11-02
Current Penalty 1362.5
Initial Penalty 1817.0
Final Order 2016-11-29
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about October 25, 2016, the ladder used to access the roof did not extend 3 feet above the landing, exposing employees to a 9 feet fall hazard.