Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-08-08
|
Emphasis |
L: HINOISE
|
Case Closed |
2019-12-13
|
Related Activity
Type |
Referral |
Activity Nr |
1369160 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100106 E02 II B 2 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-17 |
Current Penalty |
3880.2 |
Initial Penalty |
6467.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed 120 gallons of Category 2, 3, or 4 flammable liquids in containers: On or about 8/8/2018, at the jobsite location 2050 NW 94th Ave. Doral, FL 33172, the amount of category 2 flammable liquids kept outside a cabinet or storage room was 1,375 gallons (24x55 gal. drums of Autowash 6000 and 1x55gal. of MRC-F) which exceeded the allowed limit. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100133 A03 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-10 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(3): The employer did not ensure that employees wearing prescription lenses while engaged in operations that involve eye hazards wears eye protection that incorporates the prescription in its design or wears eye protection that can be worn over the prescription lenses: On or about 8/8/2018, at the jobsite location 2050 NW 94th Ave. Doral, FL 33172, an employee who was exposed to an eye injury while transferring and/or handling chemicals such as but not limited to Autowash 6000, was not protected while only wearing their prescription glasses. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-10 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about 8/8/2018, at the jobsite location 2050 NW 94th Ave. Doral, FL 33172, the employer did not develop and implement a written hazard communication program for employees exposed to chemicals such as, but not limited to LP-D3WR Plate Developer Replenisher (with a pH 12.9), and MRC-F (containing Naphtha, Xylene, IPA, Acetone and Heptane). |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 II |
Issuance Date |
2018-12-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical a) On or about 8/8/2018, at the jobsite location 2050 NW 94th Ave. Doral, FL 33172 in the press department, the container of Autowash 6000 was not labeled with the required information. b) On or about 8/8/2018, at the jobsite location 2050 NW 94th Ave. Doral, FL 33172 in the press department, the container of MRC-F (containing Naphtha, Xylene, IPA, Acetone and Heptane), was not labeled with the required information. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: On or about 8/8/2018, at the jobsite location 2050 NW 94th Ave. Doral, FL 33172, the employer did not have available the safety data sheets (SDS) for employees exposed to chemicals such as, but not limited to LP-D3WR Plate Developer Replenisher (with a pH 12.9), and MRC (containing Naphtha, Xylene, IPA, Acetone and Heptane). |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about 8/8/2018 at 2050 NW 94th Ave Doral, FL 33172, the employer did not provide employees, who voluntarily use a 3M half-face air purifying respirator with a medical evaluation. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about 8/8/2018 at 2050 NW 94th Ave Doral, FL 33172 prep department, employees would use a corrosive chemical known as LP-D3WR Plate Replenisher (with a pH 12.9), without having an eye wash station readily available. |
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-08-24
|
Emphasis |
P: AMPUTATE, N: AMPUTATE, L: FORKLIFT
|
Case Closed |
2019-12-19
|
Related Activity
Type |
Referral |
Activity Nr |
1369160 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B06 I |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-18 |
Current Penalty |
2328.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(6)(i): Employees less than 4 feet (1.2 m) above uncovered or unguarded dangerous equipment were not protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system. On or about August 24, 2018, at the Die cutting department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a fall hazard while standing in close proximity to the stock feeding system of a die-cutting machine (i.e. Heidelberg Dymatrix 105CS, Serial No. 300108) without being protected from falling. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2019-01-02 |
Current Penalty |
5432.4 |
Initial Penalty |
9054.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about August 8, 2018, at Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. The employer did not establish an energy control program, resulting in the exposure of employees to a caught by hazard while performing servicing activities of pre-press, press and bindery equipment such as, but not limited to; changing of rollers, replacement of broken and/or missing parts, changing hoses, cleaning and lubrication, etc. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-20 |
Current Penalty |
3084.0 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about August 8, 2018, at the Die cutting department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. Employees were exposed to struck and caught by hazards while a powered industrial truck (i.e. Mitsubishi, Serial No. AF82A-52267) was operated without training and/or evaluation. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2018-12-06 |
Current Penalty |
3880.2 |
Initial Penalty |
6467.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a caught by hazard while working with a drill press (i.e. Delta, Model No. 11-950) that had its point of operation not guarded. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2018-12-06 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A miter saw (i.e. Dewalt, Model No. not available) was not anchored, exposing an employee to a struck by hazard. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100215 A02 |
Issuance Date |
2018-12-06 |
Current Penalty |
4656.0 |
Initial Penalty |
7760.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a struck by hazard while working with a bench grinder (i.e. Workforce, Model No. 7065) that lacked a side guard on its right side. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2018-12-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a struck by hazard while working with a bench grinder (i.e. Workforce, Model No. 7065) that lacked a work rest on both sides. |
|
Citation ID |
01006C |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2018-12-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a struck by hazard while working with a bench grinder (i.e. Workforce, Model No. 7065) that lacked a tongue guard on its right side, and tongue guard on its left side was at more than 1/4" from the wheel periphery. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-18 |
Current Penalty |
3880.2 |
Initial Penalty |
6467.0 |
Final Order |
2018-12-26 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a caught by hazard while working in the proximity of an air compressor (i.e. Quincy QT-7.5, Model QTZST711P00187, Serial No. 5131816) which had an unguarded belt and pulleys assembly on its motor drive mechanism. b. On or about August 24, 2018, at the Bindery Department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A guard covering a belt and pulley assembly on a guillotine cutter (i.e. Polar, Model 76EM, Serial Number 5261234) was made out of cardboard and secured with Velcro, exposing employees to caught by hazard. c. On or about August 24, 2018, at the Bindery Department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A guard covering a belt and pulley assembly on a guillotine cutter (i.e. EMC-Monitor, Model 115MON, Serial Number 5531563)was made out of cardboard and secured with Velcro, exposing employees to caught by hazard. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven -7 feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a caught by hazard while working in the proximity of an air compressor (i.e. Quincy QT-7.5, Model QTZST711P00187, Serial No. 5131816) which had an unguarded belt and pulleys assembly on its motor drive mechanism. |
|
Citation ID |
01007C |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: a. On or about August 24, 2018, at the Bindery Department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A guard covering a belt and pulley assembly on a guillotine cutter (i.e. Polar, Model 76EM, Serial Number 5261234) was made out of cardboard and secured with Velcro, exposing employees to caught by hazard. b. On or about August 24, 2018, at the Bindery Department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A guard covering a belt and pulley assembly on a guillotine cutter (i.e. EMC-Monitor, Model 115MON, Serial Number 5531563)was made out of cardboard and secured with Velcro, exposing employees to caught by hazard. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-13 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-26 |
Nr Instances |
5 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On or about August 8, 2018, at the Press department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A fan (i.e. Maxx Air, BF30DD) lacked a ground prong on its attachment plug, exposing employees to an electrical shock hazard. b. On or about August 8, 2018, at the Press department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A compressor for a powder unit (i.e. AB Dick Press Powder 3) lacked a ground prong on its attachment plug, exposing employees to an electrical shock hazard. c. On or about August 24, 2018, at the Bindery department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A wall-mounted fan (i.e. info not available) lacked a ground prong on its attachment plug, exposing an employee to an electrical shock hazard. d. On or about August 24, 2018, at the Bindery department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A paper jogger (i.e. Challenge, No model info available) lacked a ground prong on its attachment plug, an exposing employee to an electrical shock hazard. e. On or about August 24, 2018, at the Die cutting department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A fan (i.e. Dayton) lacked a ground prong on its attachment plug, exposing employees to an electrical shock hazard. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2018-12-06 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed a fall hazard: On or about August 8, 2018, at the Die cutting department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. An employee was exposed to a fall hazard when performing cleaning operations while using a wood platform which was not secured to the forks and/or mast of a powered industrial truck. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2018-12-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: On or about August 8, 2018, at the warehouse area of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. Wood dust was accumulated throughout an area used to operate electrical powered equipment, exposing an employee to an smoke inhalation hazard in the event of a fire. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 C03 I |
Issuance Date |
2018-12-06 |
Abatement Due Date |
2018-12-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: On or about August 24, 2018, at the Bindery department of Nupress of Miami, 2050 NW 94th Ave, Doral, FL. A paper jogger (i.e. Challenge, Model A, Serial No. 4881) had a splice on its cord covered with electrical plastic tape, exposing an employee to an electrical shock hazard. |
|
|