Search icon

SHORES CONSTRUCTION, INC. - Florida Company Profile

Company Details

Entity Name: SHORES CONSTRUCTION, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

SHORES CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 04 Apr 1994 (31 years ago)
Date of dissolution: 11 Feb 2016 (9 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 11 Feb 2016 (9 years ago)
Document Number: P94000025532
FEI/EIN Number 593240230

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2946 MARIDALE RD, MARIANNA, FL, 32448
Mail Address: PO BOX 608, LYNN HAVEN, FL, 32444
ZIP code: 32448
County: Jackson
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SHORES JEFFERY E President 2946 MARYDALE RD, MARIANNA, FL, 32448
SHORES JEFFERY E Treasurer 2946 MARYDALE RD, MARIANNA, FL, 32448
SHORES JEFFERY E Director 2946 MARYDALE RD, MARIANNA, FL, 32448
SHORES RHONDA K Secretary 2946 MARYDALE RD, MARIANNA, FL, 32428
SHORES RHONDA K Director 2946 MARYDALE RD, MARIANNA, FL, 32428
SHORES JEFFERY Agent 2946 MARIDALE RD, MARIANNA, FL, 32448

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2016-02-11 - -
CHANGE OF PRINCIPAL ADDRESS 2000-03-01 2946 MARIDALE RD, MARIANNA, FL 32448 -
CHANGE OF MAILING ADDRESS 2000-03-01 2946 MARIDALE RD, MARIANNA, FL 32448 -
REGISTERED AGENT NAME CHANGED 2000-03-01 SHORES, JEFFERY -
REGISTERED AGENT ADDRESS CHANGED 2000-03-01 2946 MARIDALE RD, MARIANNA, FL 32448 -

Documents

Name Date
VOLUNTARY DISSOLUTION 2016-02-11
ANNUAL REPORT 2015-01-12
ANNUAL REPORT 2014-01-13
ANNUAL REPORT 2013-01-28
ANNUAL REPORT 2012-04-14
ANNUAL REPORT 2011-01-17
ANNUAL REPORT 2010-01-18
ANNUAL REPORT 2009-03-16
ANNUAL REPORT 2008-03-26
ANNUAL REPORT 2007-01-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338484033 0419700 2013-01-26 17187 SW HIGHWAY 351, HORSESHOE BEACH, FL, 32648
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2013-02-13
Emphasis L: FALL
Case Closed 2014-04-24

Related Activity

Type Inspection
Activity Nr 866803
Health Yes
Type Accident
Activity Nr 765171

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 D21
Issuance Date 2013-06-13
Abatement Due Date 2013-06-13
Current Penalty 2000.0
Initial Penalty 2800.0
Final Order 2013-07-15
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a. On or about January 25, 2013, an employee used a defective rope grab that had not been removed from service.
338668031 0419700 2013-01-26 17187 SW HIGHWAY 351, HORSESHOE BEACH, FL, 32648
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2013-03-12
Emphasis N: SILICA, L: LEAD, L: SILICA, N: LEAD
Case Closed 2013-09-30

Related Activity

Type Inspection
Activity Nr 848403
Safety Yes
Type Referral
Activity Nr 780911
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100134 E01
Issuance Date 2013-06-13
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-17
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was required to use the respirator in the workplace: a. On or about January 25, 2013, the employer did not provide medical evaluation for employees that wore 3M tight-fitting half-faced respirator and the Bullard Hood when working at the water tower.

Date of last update: 01 Mar 2025