345607402
|
0418800
|
2021-10-29
|
8501 US-27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-10-29
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2022-06-16
|
Related Activity
Type |
Referral |
Activity Nr |
1826358 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-04-18 |
Current Penalty |
6667.0 |
Initial Penalty |
10256.0 |
Final Order |
2022-05-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about 10/22/2021, in the packaging department blending room of the establishment located at 8501 U.S. Highway 27 in South Bay, Florida, an employee was exposed to amputation hazards when manually rotating a pully to perform welding work on a metering screw where the employer had not developed, documented and utilized a procedure to control potential hazardous energy for that machine. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I B |
Issuance Date |
2022-04-18 |
Abatement Due Date |
2022-05-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-05-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: On or about 10/22/2021, in the packaging department blending electrical room of the establishment located at 8501 U.S. Highway 27 in South Bay, Florida, an authorized employee applied Lockout/Tagout devices for a metering screw prior to being provided specific training on the equipment that would enable him to recognize the correct circuits shut offs when implementing and/or using energy control procedures. |
|
|
345592208
|
0418800
|
2021-10-21
|
8501 US HIGHWAY 27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-10-21
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2022-03-25
|
Related Activity
Type |
Referral |
Activity Nr |
1787811 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-01-11 |
Abatement Due Date |
2022-01-31 |
Current Penalty |
5793.0 |
Initial Penalty |
9655.0 |
Final Order |
2022-01-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about July 16, 2021, on the expansion mezzanine of the establishment located at 8501 U.S. Highway 27 in South Bay, Florida, employees were exposed to amputation hazards when changing a tote bag on a dust collector where the employer had not developed, documented, and utilized a procedure to control potential hazardous energy for that machine. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I B |
Issuance Date |
2022-01-11 |
Abatement Due Date |
2022-01-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-01-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: On or about July 16, 2021, on the expansion mezzanine of the establishment located at 8501 U.S. Highway 27 in South Bay, Florida, an affected employee was exposed to amputation hazards when changing a tote bag on a dust collector prior to being provided training that would enable him recognize the hazards associated with the lack of energy control procedures. |
|
|
343960290
|
0418800
|
2019-04-25
|
8501 U.S. HWY. 27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-04-25
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2019-04-30
|
Related Activity
Type |
Complaint |
Activity Nr |
1447189 |
Safety |
Yes |
|
|
342344298
|
0418800
|
2017-05-22
|
8501 U.S. HWY. 27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-06-16
|
Case Closed |
2017-12-27
|
Related Activity
Type |
Referral |
Activity Nr |
1214054 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2017-11-08 |
Abatement Due Date |
2017-12-06 |
Current Penalty |
8873.0 |
Initial Penalty |
12675.0 |
Final Order |
2017-12-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 5/22/2017, the employer did not ensure periodic inspections of the energy control were conducted with employees that were exposed to amputation hazards while working on Line 13. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2017-11-08 |
Abatement Due Date |
2017-12-06 |
Current Penalty |
8873.0 |
Initial Penalty |
12675.0 |
Final Order |
2017-12-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 5/22/2017, employees were exposed to amputation hazards while working on Line 13 due to lack of guarding where the rollers were located. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|
342154937
|
0418800
|
2017-03-02
|
8501 US-27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-02
|
Case Closed |
2017-08-15
|
Related Activity
Type |
Referral |
Activity Nr |
1185680 |
Safety |
Yes |
|
|
314261355
|
0418800
|
2010-04-13
|
8501 U.S. HWY. 27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-04-13
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2010-04-13
|
Related Activity
Type |
Inspection |
Activity Nr |
312149198 |
|
|
312149198
|
0418800
|
2008-09-12
|
8501 U.S. HWY. 27, SOUTH BAY, FL, 33493
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-02-27
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2009-03-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100132 A |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-12 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-12 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-12 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-12 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
5 |
Nr Exposed |
8 |
Gravity |
10 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
2500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
03 |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
2500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01010 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-12 |
Current Penalty |
3500.0 |
Initial Penalty |
3500.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
05 |
|
Citation ID |
01011 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-12 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
|
Citation ID |
01012 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 II |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
|
Citation ID |
01013 |
Citaton Type |
Serious |
Standard Cited |
19100307 C |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-18 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
2 |
Nr Exposed |
15 |
Gravity |
10 |
|
Citation ID |
01014 |
Citaton Type |
Serious |
Standard Cited |
19100333 A01 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040030 A |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-18 |
Current Penalty |
3000.0 |
Initial Penalty |
3000.0 |
Nr Instances |
3 |
Nr Exposed |
27 |
Gravity |
00 |
|
|