339023111
|
0418800
|
2013-04-24
|
5400 85TH ST, VERO BEACH, FL, 32967
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-04-24
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2019-10-22
|
Related Activity
Type |
Inspection |
Activity Nr |
714698 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2013-05-20 |
Abatement Due Date |
2013-05-24 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-06-14 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about April 24, 2013, at the above addressed jobsite. An employee was exposed to an electrical hazard while operating circuit breakers inside a panelboard (QD Load Center Cat No. QOC442L) with an unused opening not covered. b. On or about April 24, 2013, at the above addressed jobsite. An employee was exposed to an electrical hazard while operating circuit breakers inside a panelboard (Siemens Load Center G244ML3200CU) with an unused opening not covered. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100147 C01 |
Issuance Date |
2013-05-20 |
Abatement Due Date |
2013-06-13 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Final Order |
2013-06-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a. On or about April 24, 2013, at the above addressed jobsite. The employer had not established an energy control program for protecting employees from caught by and electrical hazards while cleaning up and maintaining milling machines at the CNC milling department. Vero Machine Industries Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 714698, citation number 1, item number 1 and was affirmed as a final order on 1/10/2013, with respect to a workplace located at 5400 85th St, Vero Beach, FL 32967. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19100095 D01 |
Issuance Date |
2013-05-20 |
Abatement Due Date |
2013-06-13 |
Current Penalty |
80.0 |
Initial Penalty |
80.0 |
Final Order |
2013-06-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicates that any employee's exposure may equal or exceed an 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program. a. On or about April 24, 2013, at the above addressed jobsite. The employer did not assess the noise levels or implement a monitoring program at the twin spindle lathes department for protecting employees who were exposed to noise in excess of 85 decibels during the manufacturing operations. Vero Machine Industries Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 714698, citation number 2, item number 1 and was affirmed as a final order on 1/10/2013, with respect to a workplace located at 5400 85th St, Vero Beach, FL 32967. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2013-05-20 |
Abatement Due Date |
2013-05-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-06-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. On or about April 24, 2013, at the above addressed jobsite. Two circuit breakers installed inside a panelboard (QD Load Center Cat No. QOC442L) were not identified, which exposed employees to an electrical hazard. |
|
|
337146989
|
0418800
|
2012-10-31
|
5400 85TH ST, VERO BEACH, FL, 32967
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-11-08
|
Emphasis |
N: AMPUTATE, L: EISAOF
|
Case Closed |
2019-10-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2013-01-04 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-02-04 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a. On or about 11/8/12, at the CNC mill department, Vero Machine Industries Inc. The employer had not established an energy control program for protecting employees from caught by and electrical hazards while cleaning up and maintaining milling machines. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-02-04 |
Nr Instances |
4 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At Vero Machine Industries Inc. a. At the deburring department, an employee was exposed to a caught by hazard while working with a drill press (i.e. Grizzly Industrial, Model G7944) that lacked a guard on its point of operation, on or about 10/31/12. b. At the manual machinery department, an employee was exposed to a caught by hazard while working with a lathe (i.e. Meuser & Co MOL-36965) that lacked a guard on its point of operation, on or about 10/31/12. c. At the manual machinery department, an employee was exposed to a caught by hazard while working with a lathe (i.e. Hardinge Super-Precision) that lacked a guard on its point of operation, on or about 10/31/12. d. At the manual machinery department, an employee was exposed to a caught by hazard while working with a belt sander that lacked a guard at pinch point areas, on or about 11/08/12. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-02-04 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about 10/31/12, at the deburring department, Vero Machine Industries Inc. a. An employee was exposed to a struck by hazard while working with a drill press (i.e. Grizzly Industrial, Model G7944) that was not anchored. b. An employee was exposed to a struck by hazard while working with an arbor press (i.e. 2-1/2 p) that was not anchored. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100217 B03 I |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(b)(3)(i): Mechanical power press(es) using full revolution clutches did not incorporate a single-stroke mechanism: a. On or about 10/31/12, at the assembly department, Vero Machine Industries Inc. An employee was exposed to a caught by hazard while using a press that lacked a single-stroke mechanism for clamping tools. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i a. On or about 10/31/12, at the deburring department, Vero Machine Industries Inc. An employee was exposed to a struck by hazard while using air for cleaning parts at 100psi or more. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100095 D01 |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2012-12-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicates that any employee's exposure may equal or exceed an 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program. a. On or about 11/8/12, at the twin spindle lathes department, Vero Machine Industries Inc. The employer did not assess the noise levels or implement a monitoring program for employees who were exposed to noise in excess of 85 decibels during the manufacturing operations. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 L05 |
Issuance Date |
2012-12-10 |
Abatement Due Date |
2012-12-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-02-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(5): Where an operator had previously received training in a topic specified in paragraph (l)(3) of this section, and such training was appropriate to the truck and working conditions encountered, additional training in that topic is not required if the operator has been evaluated and found competent to operate the truck safely: a. On or about 11/8/12, at the saw room, Vero Machine Industries Inc. The employer did not evaluate an employee which was previously trained to make sure that he was competent to operate truck safely, exposing the employee to a struck by hazard. |
|
|