Entity Name: | ALL SEASONS ROOFING INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
ALL SEASONS ROOFING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 06 Dec 1993 (31 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 29 Sep 2010 (15 years ago) |
Document Number: | P93000084333 |
FEI/EIN Number |
593210124
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2722 ST ANTHONY DR, VALRICO, FL, 33594 |
Mail Address: | 2722 ST ANTHONY DR, VALRICO, FL, 33594 |
ZIP code: | 33594 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
WANCIO DEBORAH A | Vice President | 2722 ST ANTHONY DR, VALRICO, FL, 33594 |
KYLE KRISTOPHER T | President | 2722 ST ANTHONY DR, VALRICO, FL, 33594 |
WANCIO DEBORAH A | Agent | 2722 ST ANTHONY DR, VALRICO, FL, 33594 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REINSTATEMENT | 2010-09-29 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2010-09-24 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-22 |
ANNUAL REPORT | 2023-02-14 |
ANNUAL REPORT | 2022-02-16 |
ANNUAL REPORT | 2021-03-30 |
ANNUAL REPORT | 2020-06-02 |
ANNUAL REPORT | 2019-02-20 |
ANNUAL REPORT | 2018-03-27 |
ANNUAL REPORT | 2017-04-07 |
ANNUAL REPORT | 2016-04-28 |
ANNUAL REPORT | 2015-03-30 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338920879 | 0420600 | 2013-02-27 | 901 W BRANDON BLVD, BRANDON, FL, 33511 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 805924 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2013-05-31 |
Abatement Due Date | 2013-05-31 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. (a) for employees working at Amscot located at 901 W. Brandon Blvd. Brandon (FL), as observed on or about 02/27/2013. Employees were performing commercial roofing and were exposed to fall hazards of 19 feet. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260502 H01 V |
Issuance Date | 2013-05-31 |
Abatement Due Date | 2013-06-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-25 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: a) for employees working at 901 W. Brandon Blvd in Brandon (FL), as observed on or about 02/27/2013. Employees were performing commercial roofing and exposed to fall hazards of 19 feet. The employee assigned "monitor" duty was also perfomring roofing operations. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260502 F01 |
Issuance Date | 2013-05-31 |
Abatement Due Date | 2013-05-31 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-06-25 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: a) for employees working at Amscot located at 901 W. Brandon Blvd in Brandon (FL), as observed on or about 02/27/2013. Employees were performing commercial roofing and exposed to fall hazards of 19 feet. The warning line was only erected in a small area with a portion of it being collapsed from the wind. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260502 F02 II |
Issuance Date | 2013-05-31 |
Abatement Due Date | 2013-05-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-25 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface. a) for employees working on the roof of an Amscot located at 901 W. Brandon Blvd Brandon (FL) as observed on or about 02/27/2013. The warning line installed had a noticeable sag in the middle caused from one of the stanchions being knocked down from the wind and then placed too close together on or about 02/27/13. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19260502 F02 III |
Issuance Date | 2013-05-31 |
Abatement Due Date | 2013-05-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-25 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(f)(2)(iii): After being erected, the stanchions were not capable of resisting, without tipping over, a force of at least 16 pounds (71 N) applied horizontally against the stanchion, 30 inches (.8 m) above the walking/working surface, perpendicular to the warning line, and in the direction of the floor, roof, or platform edge; a) in that, the wind had blown over one part of the wooden stanchions at the location of 901 W. Brandon Blvd Brandon FL, as observed on or about 02/27/13. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260503 B01 |
Issuance Date | 2013-05-31 |
Abatement Due Date | 2013-06-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-25 |
Nr Instances | 1 |
Nr Exposed | 6 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) for employees working on the roof of an Amscot located at 901 W. Brandon Blvd in Brandon (FL) on or about 02/27/13. A pre-start "Tool Box" training session held by the Employer that detaied the means of fall protection and ladder use was not documented. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6660638604 | 2021-03-23 | 0455 | PPS | 2722 Saint Anthony Dr, Valrico, FL, 33594-3807 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5285887703 | 2020-05-01 | 0455 | PPP | 2722 SAINT ANTHONY DR, VALRICO, FL, 33594-3807 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 01 May 2025
Sources: Florida Department of State