Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-01-30
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2017-08-04
|
Related Activity
Type |
Referral |
Activity Nr |
1178250 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1206656 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2017-06-16 |
Abatement Due Date |
2017-06-22 |
Current Penalty |
5070.0 |
Initial Penalty |
5070.0 |
Final Order |
2017-08-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On or about January 30, 2017, at the above addressed jobsite, an employee was exposed to an amputation hazard while conducting portable table saw operations without the required guarding system. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-03-26
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2015-08-11
|
Related Activity
Type |
Complaint |
Activity Nr |
877223 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2014-08-05 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-08-27 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of flying particles from a compressed air system that had been constructed of plastic tubing that had ruptured. a) On or about March 16, 2014, at the above addressed job site, employees were exposed to struck by hazards from flying particles from several instances where the plastic tubing that had been used for a compressed air system had ruptured. PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100213 A12 |
Issuance Date |
2014-08-05 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-08-27 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(a)(12): The portion of circular saw(s) beneath or behind the table, where there was a possibility of contact with the saw, was not covered with a guard or exhaust hood: a) On or about March 16, 2014, at the above addressed job site, employees were exposed to struck-by and amputation hazard while operating a table saw to cut wood products that had been lacking a guard and an exhaust hood. 2 instances: 1. Powermatic table saw. 2. Panhans table saw. PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 B03 |
Issuance Date |
2014-08-05 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-08-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: a) On or about March 16, 2014, at the above addressed job site, employees were exposed to a struck by hazard while operating a band saw to cut wooden parts that lacked an emergency stop switch and an anti- restart switch. PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2014-08-05 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-08-27 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. a) On or about March 16, 2014, at the above addressed job site, employees were exposed to struck - by and laceration hazards from using air nozzles to clean wood dust from parts and equipment that were supplied with approximately 120 psi. of air pressure. 2 instances: 1. An air nozzle was observed at the west work bench. 2. An air nozzle was observed at the east work bench. PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100334 A03 I |
Issuance Date |
2014-08-05 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-08-27 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor: a. On or about March 16, 2014, at the above addressed job site, employees were exposed to shock and electrocution hazard while using pedestal fans with defective 110 VAC power cords with plugs that lacked grounding pins. 3 instances: 1. Pedestal Fan Model FE6-75S110L. 2. Global Pedestal Fan Model FS65X. 3. Pedestal Fan, Patton Electric Company, Model 1010MP-I. PLEASE NOTE THAT DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-08-05 |
Abatement Due Date |
2014-08-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-08-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about February 4, 2014, at the above addressed job site, the employer had not developed and implemented a written Hazard Communication Program for employees who had been assembling wooden components while using hazardous chemicals such as but not limited to adhesives, lacquer thinner, and mineral spirits. |
|
|