Search icon

GULFSIDE ROOFING, INC. - Florida Company Profile

Company Details

Entity Name: GULFSIDE ROOFING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GULFSIDE ROOFING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 16 Nov 1992 (32 years ago)
Document Number: P92000004584
FEI/EIN Number 650382449

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3219 63RD AVENUE EAST, BRADENTON, FL, 34203
Mail Address: 3219 63RD AVENUE EAST, BRADENTON, FL, 34203
ZIP code: 34203
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TOOLE DONALD W President 3219 63RD AVENUE EAST, BRADENTON, FL, 34203
Toole Jolene S vice 3219 63RD AVENUE EAST, BRADENTON, FL, 34203
O Connell John T Manager 3219 63RD AVENUE EAST, BRADENTON, FL, 34203
TOOLE DONALD W Agent 3219 63RD AVENUE EAST, BRADENTON, FL, 34203

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 1993-01-08 TOOLE, DONALD W -
REGISTERED AGENT ADDRESS CHANGED 1993-01-08 3219 63RD AVENUE EAST, BRADENTON, FL 34203 -

Documents

Name Date
ANNUAL REPORT 2024-04-10
ANNUAL REPORT 2023-04-11
ANNUAL REPORT 2022-04-11
ANNUAL REPORT 2021-05-03
ANNUAL REPORT 2020-06-29
ANNUAL REPORT 2019-04-01
ANNUAL REPORT 2018-01-08
ANNUAL REPORT 2017-04-25
ANNUAL REPORT 2016-04-28
ANNUAL REPORT 2015-04-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340186204 0420600 2015-01-06 4408 GULF DRIVE, HOLMES BEACH, FL, 34217
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-01-06
Emphasis L: EISAOF, P: FALL, L: FALL, L: EISAX
Case Closed 2016-04-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2015-02-03
Abatement Due Date 2015-02-13
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a) For employees working at 4408 Gulf Drive in Holmes Beach, as observed on or about January 6, 2015. Employees were on the roof working without the use of a fall protection system in place. Employees were exposed to a fall hazard of approximately 9 feet 8 inches.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2015-02-03
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using power supplied through an extension cord that was not protected by a ground fault circuit interrupter.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260403 B01 III
Issuance Date 2015-02-03
Abatement Due Date 2015-02-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(iii): Safety of equipment was not determined on the basis of electrical insulation. a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using a reciprocating saw that was not inspected prior to use and had a severely damaged power cord at the point closest to the tool housing.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260405 A02 II I
Issuance Date 2015-02-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using an extension cord that passed through a doorway and was not protected to avoid damage
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2015-02-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-27
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using power supplied through an extension cord that did not have proper strain relief.
305643355 0420600 2002-08-19 1303 17TH ST, WEST, PALMETTO, FL, 34221
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2002-08-19
Emphasis L: FLCARE, L: FALL, S: CONSTRUCTION
Case Closed 2002-09-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2002-09-11
Abatement Due Date 2002-09-16
Current Penalty 375.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 4
Gravity 03

Date of last update: 02 Apr 2025