347673014
|
0420600
|
2024-08-06
|
202 PROGRESS ROAD SUITE 2700, AUBURNDALE, FL, 33823
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-08-06
|
Emphasis |
N: AMPUTATE
|
Related Activity
Type |
Referral |
Activity Nr |
2194632 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-08-21 |
Abatement Due Date |
2024-09-17 |
Current Penalty |
88721.0 |
Initial Penalty |
88721.0 |
Contest Date |
2024-09-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about 07/31/2024, at 202 Progress Road, Auburndale, Florida 33823, an employee was operating a belling machine/plastic extrusion machine, during which time the point of operation on the machine was not guarded, therefore exposing the employee to an amputation hazard. The employer, CANTEX INC., was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a)(1), which was contained in OSHA number 1460253, citation number 01, Item number 001, and was affirmed as a final order on 03/23/2020, with respect to a workplace located at 2101 Se 1st Street, Mineral Wells, TX 76067. |
|
|
342316775
|
0420600
|
2017-05-10
|
202 PROGRESS RD, AUBURNDALE, FL, 33823
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2017-10-11
|
Emphasis |
L: HINOISE
|
Case Closed |
2017-10-11
|
Related Activity
Type |
Referral |
Activity Nr |
1206888 |
Health |
Yes |
|
|
342280559
|
0420600
|
2017-04-25
|
202 PROGRESS ROAD, AUBURNDALE, FL, 33823
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-04-25
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2017-08-17
|
Related Activity
Type |
Referral |
Activity Nr |
1202800 |
Safety |
Yes |
|
|
339566150
|
0420600
|
2014-01-28
|
202 PROGRESS RD, AUBURNDALE, FL, 33823
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-01-28
|
Emphasis |
L: EISAX, L: EISAOF, L: FALL, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2014-04-14
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 E01 |
Issuance Date |
2014-04-02 |
Current Penalty |
2700.0 |
Initial Penalty |
4500.0 |
Final Order |
2014-04-11 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a. At the establishment, employees were exposed to an 8 foot fall hazard, in that, there was no intermediate or mid rail on the hopper platforms, on or about 01/28/14. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-04-02 |
Current Penalty |
2700.0 |
Initial Penalty |
4500.0 |
Final Order |
2014-04-11 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. At the establishment employees were exposed to an amputation hazard, in that, while using the Balador Relance drill press no guard was present, on or about 01/28/2014 b. At the establishment, employees are exposed to an amputation hazard, in that, the drive rollers and gears on labeling machine were not guarded, on or about 01/28/2014. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2014-04-02 |
Current Penalty |
1377.0 |
Initial Penalty |
2295.0 |
Final Order |
2014-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a. At the establishment, employees were exposed to a struck by hazard, in that, the Balador Reliance drill press was not secured to the floor, on or about 01/28/2014. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2014-04-02 |
Current Penalty |
1377.0 |
Initial Penalty |
2295.0 |
Final Order |
2014-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. At the establishment, employees were exposed to an amputation hazard, in that, the work rest on the Wissota bench grinder was 1/2 inch from the wheel, on or about 01/28/2014. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2014-04-02 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Final Order |
2014-04-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or over current device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. a. At the establishment, breaker panel switches in BP1 and BP2 were not labeled, on or about 01/28/14. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 II |
Issuance Date |
2014-04-02 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Final Order |
2014-04-11 |
Nr Instances |
2 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a. At the establishment, employees were exposed to a electrocution hazard,in that, the flexible cord on the Baldor Reliance drill press, was spliced with electrical tape, on or about 01/28/14. b. At the establishment, employees were exposed to a shock hazard, in that, the flexible cord on the labeling machine was spliced with caps, on or about 01/28/2014 |
|
|
301970240
|
0420600
|
1998-05-29
|
STADIUM RD. & BENNETT ST., AUBURNDALE, FL, 33823
|
|
Inspection Type |
Planned
|
Scope |
Records
|
Safety/Health |
Safety
|
Close Conference |
1998-05-29
|
Emphasis |
N: GSINTARG
|
Case Closed |
1998-06-24
|
|
301970257
|
0420600
|
1998-05-29
|
STADIUM RD. & BENNETT ST., AUBURNDALE, FL, 33823
|
|
Inspection Type |
Planned
|
Scope |
Records
|
Safety/Health |
Health
|
Close Conference |
1998-05-29
|
Emphasis |
N: GSINTARG
|
Case Closed |
1998-06-04
|
|
109206581
|
0420600
|
1998-02-10
|
STADIUM RD. & BENNETT ST., AUBURNDALE, FL, 33823
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1998-02-10
|
Case Closed |
1998-05-15
|
Related Activity
Type |
Referral |
Activity Nr |
902490770 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
1998-03-17 |
Abatement Due Date |
1998-03-20 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 C04 I |
Issuance Date |
1998-03-17 |
Abatement Due Date |
1998-03-23 |
Current Penalty |
1500.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
1998-03-17 |
Abatement Due Date |
1998-03-23 |
Current Penalty |
1500.0 |
Initial Penalty |
1500.0 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
02 |
|
|
109707125
|
0420600
|
1993-10-20
|
STADIUM RD. & BENNETT ST., AUBURNDALE, FL, 33823
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
1993-11-23
|
Case Closed |
1993-12-29
|
Related Activity
Type |
Referral |
Activity Nr |
901683912 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100134 B03 |
Issuance Date |
1993-11-30 |
Abatement Due Date |
1994-01-02 |
Initial Penalty |
1125.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100134 E03 |
Issuance Date |
1993-11-30 |
Abatement Due Date |
1994-01-02 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
01 |
|
|