Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-04-03
|
Case Closed |
2019-06-05
|
Related Activity
Type |
Referral |
Activity Nr |
1435015 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100106 H08 III |
Issuance Date |
2019-05-09 |
Current Penalty |
4773.6 |
Initial Penalty |
7956.0 |
Final Order |
2019-05-20 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(h)(8)(iii): Combustible waste material and residues in a building or operating area shall be kept to a minimum, stored in closed metal waste cans, and disposed of daily: On or about March 19, 2019, at the jobsite location 591 SW 13th Terrace Pompano Beach, FL 33069 assembly department, the rags used for the brake cleaner (Category 2 flammable) were dispensed into an opened bag, exposing employees to a fire hazard. - |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 B03 |
Issuance Date |
2019-05-09 |
Current Penalty |
3182.4 |
Initial Penalty |
5304.0 |
Final Order |
2019-05-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, when combustible, was not covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues: On or about March 19th, 2019, at the 591 SW 13th Terrace Pompano Beach, FL 33069 spray booth, the operator's working area inside the spray booth walls were covered with combustible cardboard, exposing employees to a fire hazard while using a flammable Category 3 paint inside the booth. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2019-05-09 |
Current Penalty |
3182.4 |
Initial Penalty |
5304.0 |
Final Order |
2019-05-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances, severe cuts or lacerations, severe abrasions, punctures, chemical burns, thermal burns, and harmful temperature extremes: On or about March 19,2019, at 591 SW 13th Terrace Pompano Beach, FL pre-assembly area, employees handling liquid nitrogen were exposed to thermal burns while not having appropriate hand protection. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2019-05-09 |
Current Penalty |
4773.6 |
Initial Penalty |
7956.0 |
Final Order |
2019-05-20 |
Nr Instances |
1 |
Nr Exposed |
25 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about March 19, 2019, at the jobsite location 591 SW 13th Terrace Pompano Beach, FL 33069, the employer did not develop and implement a written hazard communication program for employees exposed to hazardous chemicals including, but not limited to, Reducer (Category 2 flammable), and Liquid Nitrogen (Cryogenic Liquid). |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 II |
Issuance Date |
2019-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-20 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical On or about March 19, 2019, at the jobsite location 591 SW 13th Terrace Pompano Beach, FL 33069 in the assembly line, the container of Brakleen Brake Parts Cleaner (Category 2 flammable), was not labeled with the required information. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2019-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-20 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: On or about March 19, 2019, at 591 SW 13th Terrace Pompano Beach, FL 33069 paint department, the employer did not develop a written respiratory protection program that included those employees wearing 3M powered air purifying respirators (PAPR). |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-02-28
|
Emphasis |
P: AMPUTATE, N: AMPUTATE, L: FORKLIFT
|
Case Closed |
2019-06-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2019-05-09 |
Current Penalty |
3864.0 |
Initial Penalty |
6440.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: On or about 2/28/2019, at the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069. An uncapped oxygen cylinder was placed where it could be easily knocked down, exposing employees to fire and struck by hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 B08 |
Issuance Date |
2019-05-09 |
Current Penalty |
4546.2 |
Initial Penalty |
7577.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(8): Each spray booths was not separated from other operations by not less than 3 feet, or by a greater distance, or by such partition or wall as to reduce the danger from juxtaposition of hazardous operations. On or about 2/28/2019, at the Axle Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069, a workstation was placed adjacent to a spray booth, exposing employees working in the area to a fire hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100107 G02 |
Issuance Date |
2019-05-09 |
Current Penalty |
4546.2 |
Initial Penalty |
7577.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: On or about 3/19/2019, at the Axle Department, 591 SW 13th Terrace Pompano Beach, FL 33069. The interior of a spray booth which was cleaned once a year had accumulated 3-4-inches of combustible residues/deposits due to the spraying process, exposing an employee to a fire hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100178 C02 III |
Issuance Date |
2019-05-09 |
Abatement Due Date |
2019-05-23 |
Current Penalty |
3409.8 |
Initial Penalty |
5683.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(c)(2)(iii): Power-operated industrial trucks other than those designated as EX were used in atmospheres containing any of the chemicals referenced in this section in quantities sufficient to produce explosive or ignitable mixtures and where such concentrations of these gases or vapors exist continuously, intermittently or periodically under normal operating conditions: On or about 3/19/2019, at the Axle Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069, a LPG type powered industrial truck (i.e. Caterpillar, Model GC55K, Serial #AT88A00291) was used inside a spray paint booth to transport axles from storage to the interior of the spray booth for painting, exposing employees to Class 1 Division 2 fire and explosion hazards. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2019-05-09 |
Current Penalty |
4546.2 |
Initial Penalty |
7577.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 2/28/2019, at the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL. Employees were exposed to struck and caught by hazards while operating a powered industrial truck without training and/or evaluation. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2019-05-09 |
Current Penalty |
4546.2 |
Initial Penalty |
7577.0 |
Final Order |
2019-05-22 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about 2/28/2019, at the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069. a. An employee was exposed to a caught by hazard while working with a drilling machine (i.e. Baileigh, Model VHD-40G, Serial #110420) whose point of operation was not guarded. b. An employee was exposed to a caught by hazard while working with a drill press (i.e. SM, Type -6T) whose point of operation was not guarded. c. An employee was exposed to a caught by hazard while working with a drill press (i.e. Dayton, 20-inches) whose point of operation was not guarded. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2019-05-09 |
Current Penalty |
4546.2 |
Initial Penalty |
7577.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: At the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069. An employee was exposed to a struck by hazard while working with a bench grinder (i.e. Wissota, Modelo F-33) that had its right side workrest placed at 1-inch from the wheel. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2019-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: At the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069. An employee was exposed to a struck by hazard while working with a bench grinder (i.e. Wissota, Modelo F-33) that lacked a tongue guard on its right side. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100243 C03 |
Issuance Date |
2019-05-09 |
Current Penalty |
3409.8 |
Initial Penalty |
5683.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: On or about 2/28/2019, at the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069, an employee was exposed to caught and struck by hazards while working with an angle grinder (i.e. Porter Cable, PC60TAG) that lacked a guard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2019-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-05-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: At the Engine Department of Man Engines & Components Inc., 591 SW 13th Terrace, Pompano Beach, FL 33069. A drilling machine (i.e. Baileigh, Model VHD-40G, Serial No. Not available) lacked strain relief where cord entered into the attachment plug, exposing an employee to an electrical hazard. |
|
|