Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-12-18
|
Emphasis |
N: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B01 |
Issuance Date |
2025-01-03 |
Abatement Due Date |
2025-01-30 |
Current Penalty |
3871.2 |
Initial Penalty |
6452.0 |
Final Order |
2025-01-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. On the roof of a residence, located at 37709 Fraser Road, Zephyrhills, Florida 33544: On or about 12/18/24, the employer expose employees to fall and struck by hazards, in that a written Safety and Health Program was not utilized by the employer before performing siding activities. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2025-01-03 |
Abatement Due Date |
2025-01-30 |
Current Penalty |
1659.0 |
Initial Penalty |
2765.0 |
Final Order |
2025-01-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On the roof of a residence, located at 37709 Fraser Road, Zephyrhills, Florida 33544: On or about 12/18/24, the employer expose employees to struck by hazards, in that hard hats were not utilized by employees while performing siding activities. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2025-01-03 |
Abatement Due Date |
2025-01-30 |
Current Penalty |
2212.2 |
Initial Penalty |
3687.0 |
Final Order |
2025-01-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On the roof of a residence, located at 37709 Fraser Road, Zephyrhills, Florida 33544: On or about 12/18/24, the employer expose employees to struck by hazards, in that safety glasses were not utilized by employees using nail guns while performing siding activities. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2025-01-03 |
Abatement Due Date |
2025-01-30 |
Current Penalty |
3871.2 |
Initial Penalty |
6452.0 |
Final Order |
2025-01-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On the roof of a residence, located at 37709 Fraser Road, Zephyrhills, Florida 33544: On or about 12/18/24, the employer expose employees to fall hazards, in that fall protection was not utilized by employees while performing siding activities. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2025-01-03 |
Abatement Due Date |
2025-01-30 |
Current Penalty |
2766.0 |
Initial Penalty |
4610.0 |
Final Order |
2025-01-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On a roof of a residence, located at 37709 Fraser Road, Zephyrhills, Florida 33544: On or about 12/18/24, the employer expose employees to fall hazards, in that the ladder used for access did not extend three feet above the landing area while performing siding activities. |
|
|