Search icon

HIGHWAY SYSTEMS INCORPORATED - Florida Company Profile

Company Details

Entity Name: HIGHWAY SYSTEMS INCORPORATED
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HIGHWAY SYSTEMS INCORPORATED is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 13 Sep 2023 (2 years ago)
Document Number: P23000066271
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 1000 WATER STREET, 2001, TAMPA, FL, 33602
Mail Address: 1000 WATER STREET, 2001, TAMPA, FL, 33602
ZIP code: 33602
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
BELL JASON S Chief Executive Officer 1000 WATER STREET 2001, TAMPA, FL, 33602
BELL JASON S Agent 1000 WATER STREET, TAMPA, FL, 33602

Documents

Name Date
ANNUAL REPORT 2024-02-07
Domestic Profit 2023-09-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342864238 0420600 2018-01-05 1749 CR 525 EAST, SUMTERVILLE, FL, 33585
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-01-17
Emphasis N: PMETALS, P: PMETALS, L: FORKLIFT
Case Closed 2018-03-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2018-01-23
Current Penalty 2473.8
Initial Penalty 4123.0
Final Order 2018-02-02
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Prefabrication area, employees were exposed to a rotating saw blade, in that, 24 inches of the non-cutting portion of the DO-ALL vertical band saw was not provided with a guard to enclose the blade, on or about 01/05/2018. b. Prefabrication area, employees were exposed to a rotating saw blade, in that, 14 inches of the non-cutting portion of the Hydmech horizontal band saw was not provided with a guard to enclose the blade, on or about 01/05/2018.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2018-01-23
Abatement Due Date 2018-02-09
Current Penalty 2910.0
Initial Penalty 4850.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. Prefabrication area, employees were exposed to amputation hazards, in that, the point of operation of a foot pedal operated 90 ton Cincinnati press brake was not provided with a guard, on or about 01/05/2018.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2018-01-23
Current Penalty 1746.0
Initial Penalty 2910.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. Prefabrication area, employees were exposed to a struck-by hazard, in that, the work rest of the Northern Industrial 8 inch pedestal grinder was 1 inch from the grinding wheel, on or about 01/05/2018.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2018-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. Prefabrication area, employees were exposed to a struck-by hazard, in that, a tongue guard was not provided on the Northern Industrial 8 inch pedestal grinder, on or about 01/05/2018.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100252 B02 III
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 2328.0
Initial Penalty 3880.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 25
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles to protect them from the rays when noncombustible or flameproof screens or shields were not used: a. At the fabrication areas where welding is conducted, employees adjacent to welding or walking by the welding areas were not protected either by wearing protective eyewear or by having shields or screens enclosing the welding stations, on or about 01/05/2018.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D01
Issuance Date 2018-01-23
Abatement Due Date 2018-02-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a. At the manufacturing areas, a personal protective equipment hazard assessment was not conducted to address the following: 1. Selection and use of personal protective equipment that would adequately protect employees. 2. Communicating selection decision to each affected employee. 3. Selecting the personal protective equipment that properly fits each employee. On or about 01/05/2018.
Citation ID 02002
Citaton Type Other
Standard Cited 19100147 C04 I
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. Prefabrication welding manufacturing area, employees were exposed to the hazard of inadvertent energization or release of stored energy during maintenance operations on equipment such as, but not limited to, vertical and horizontal band saws, Geka Hydrocrop 110 ironworker, Cincinnati 90 ton press brake and Hypertherm burn table plasma cutter. Equipment specific lockout/tagout procedures were not developed and implemented to include at a minimum the following: 1. A specific statement of the intended use of the procedure. 2. Specific procedural steps for shutting down, isolating, blocking, and securing machines or equipment to control hazardous energy. 3. Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. 4. Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices and other energy control measures. 5. The magnitude of hazardous energy. On or about 01/05/2018.
Citation ID 02003
Citaton Type Other
Standard Cited 19100157 E02
Issuance Date 2018-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-02-02
Nr Instances 1
Nr Exposed 40
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a. At the facility, portable fire extinguishers were not visually inspected monthly as required to assure their ongoing integrity, on or about 01/05/2018.
Citation ID 02004
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2018-01-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-02-02
Nr Instances 2
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Break alarm area, employees were exposed to an electrical hazard, in that, an extension cord was used in place of fixed wiring and was run on the building wall behind wooden panels and was used to provide power to the buzzard alarm, on or about 01/05/2018. b. West wall of the prefabrication area, employees were exposed to an electrical hazard, in that, a red extension cord was used to provide power to a multi-outlet power strip located on a working bench, on or about 01/05/2018.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1739320 Intrastate Non-Hazmat 2019-11-26 161000 2018 5 3 Private(Property)
Legal Name HIGHWAY SYSTEMS INCORPORATED
DBA Name -
Physical Address 1749 CR 525 E, SUMTERVILLE, FL, 33585, US
Mailing Address 1749 CR 525 E, SUMTERVILLE, FL, 33585, US
Phone (352) 748-4258
Fax (352) 402-0343
E-mail VINCEP@HIGHWAYSYSTEMSINC.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 01 May 2025

Sources: Florida Department of State